Related papers: A GEM readout with radial zigzag strips and linear…
In the context of the Silicon tracking for a Linear Collider (SiLC) R&D collaboration, a highly compact mixed-signal chip has been designed in 130nm CMOS technology intended to read Silicon strip detectors for the experiments at the future…
Large-size hybrid and pixelized GEM-Micromegas gaseous detectors (40x40 cm$^2$ active area) were developed and installed in 2014 and 2015 for the COMPASS2 physics program which started at the same time. That program involved in particular…
We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with…
Low-energy electron recoils are of interest in several planned and proposed future nuclear and particle physics experiments. The topology and directions of such recoils provide important particle identification and kinematical constraints,…
Rydberg atomic quantum receivers (RAQRs) offer quantum-limited sensitivity and broadband tunability. It is not obvious whether this device-level advantage also improves network reliability, since in dense deployments, aggregate interference…
Plasmons in two-dimensional electron gas (2DEG) strips with grounded electrodes (a gate or side contacts) are investigated. We consider two systems: (a) the 2DEG strip with a highly conducting gate and (b) the 2DEG strip with semi-infinite…
A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active…
A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…
The detection of astrophysical Gamma-Ray Bursts (GRBs) has always been intertwined with the challenge of identifying the direction of the source. Accurate angular localization of better than a degree has been achieved to date only with…
We measured the physical lateral resolution of the electron backscatter diffraction (EBSD) technique for the case of pure magnesium and tungsten. Spatial resolution, among other parameters, depends significantly on the accelerating voltage…
THGEMs (THick Gas Electron Multiplier) of varying thickness, hole diameter and hole pitch have been studied. For a thinner-THGEM of thickness 0.2 mm, with hole diameter 0.2 mm, pitch 0.2 mm and narrow (5-10 {\mu}m) rim, the performance of…
We present a compact, ionization-based detector for the state-selective and spatially resolved measurement of individual Rydberg atoms trapped in the vicinity of an atom chip. The system combines an electrostatic lens system for guiding…
We present a study of the Angular Resolution of the AGILE gamma-ray imaging detector (GRID) that is operational in space since April 2007. The AGILE instrument is made of an array of 12 planes each equipped with a Tungsten converter and…
In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this…
The presence of structure-dependent edge states of graphite is revealed by both ambient- and ultra-highvacuum- (UHV) scanning tunneling microscopy (STM) / scanning tunneling spectroscopy (STS) observations. On a hydrogenated zigzag…
Current and next-generation particle tracking detectors will incorporate precision timing capabilities with resolutions approaching tens of picoseconds. Using Technology Computer-Aided Design (TCAD) simulations of Low-Gain Avalanche Diode…
The ARGO-YBJ experiment, currently under construction at the Yangbaijing Laboratory (4300 m a.s.l.), consists of a single layer of about 2000 Resistive Plate Chambers (RPCs) for a total instrumented area of about 6700 m^2. The digital…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…
Piggyback Micromegas consists in a novel readout architecture where the anode element is made of a resistive layer on a ceramic substrate. The resistive layer is deposited on the thin ceramic substrate by an industrial process which…
A high momentum resolution is required for the precision measurement of Higgs boson at the International Linear Collider (ILC) using the recoil mass technique. The International Large Detector (ILD) is designed to meet this requirement by…