Related papers: Intrinsic Resolution of Compton Electrons in CeBr3…
X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. We report high-resolution inelastic X-ray scattering experiments with high momentum and…
We demonstrate sub-wavelength imaging of excitons confined to single CdTe quantum dots. By combining slit-confocal microscopy with a hemispherical solid immersion lens we simultaneously map the emission of thousands of single quantum dots…
The Indian Coherent Neutrino-nucleus Scattering Experiment(ICNSE) has been proposed at Bhabha Atomic Research Centre in India to measure the coherent elastic neutrino-nucleus scattering process using electron antineutrinos produced from…
Macroscopic spontaneous coherence of exciton-polariton in semiconductor cavity is one important research field in condensed matter physics. All-inorganic micro/nanowire Fabry-P\'erot cavity with excellent optical performance makes it…
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has…
We use data from the COHERENT CsI[Na] scintillation detector to constrain sub-GeV leptophobic dark matter models. This detector was built to observe low-energy nuclear recoils from coherent elastic neutrino-nucleus scattering. These…
The $^3$He(n,p) process is excellent for neutron detection between thermal and $\sim$4\,MeV because of the high cross section and near-complete energy transfer from the neutron to the proton. This process is typically used in gaseous forms…
Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…
Detection of photons with scintillating inorganic crystals in the high-energy range (> 0.1 MeV) will be discussed, making a comparison with other available methods. Energy resolutions up to 2 % at 662 keV and fast decay time of the order of…
An 800L liquid xenon scintillation $\gamma$ ray detector is being developed for the MEG experiment which will search for $\mu^+\to\mathrm{e}^+\gamma$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by…
Measurements have been performed of scintillation light intensities emitted from various inorganic scintillators irradiated with low-energy beams of highly-charged ions from an electron beam ion source (EBIS) and an electron cyclotron…
Lead halide perovskite nanocrystals demonstrate efficient up-conversion, although the precise mechanism remains a subject of active research. This study utilizes steady-state and time-resolved spectroscopy methods to unravel the mechanism…
Coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) has significantly improved with advancements in scintillators, photodetectors, and readout electronics. Achieving a CTR of 100 ps remains challenging…
Conventional scintillator-based X-ray imaging typically captures the full spectral of X-ray photons without distinguishing their energy. However, the absence of X-ray spectral information often results in insufficient image contrast,…
Cesium lead bromide (CsPbBr$_3$) is a representative material of the emerging class of lead halide perovskite semiconductors that possess remarkable optoelectronic properties. Its optical properties in the vicinity of the band gap energy…
Reducing the intrinsic emittance of photocathodes is one of the most promising routes to improving the brightness of electron sources. However, when emittance growth occurs during beam transport (for example, due to space-charge), it is…
A prototype of LaBr3:Ce in situ gamma-ray spectrometer for marine environmental monitoring is developed and applied for in situ measurement. A 3-inch LaBr3:Ce scintillator is used in the detector, and a digital pulse process electronics is…
For a first characterization, we used the two KETEK-PM3325-WB SiPMs each equipped with a 3x3x5 mm${}^3$ LYSO scintillation crystal provided with the PETsys TOFPET2 ASIC Evaluation Kit. We changed the lower of two discriminator thresholds…
The applicability of LaBr3:Ce detectors for high count rate {\gamma}-ray spectroscopy is investigated. A 3"x3" LaBr3:Ce detector is used in a test setup with radioactive sources to study the dependence of energy resolution and photo peak…
BESIII (BEijing Spectrometer III) is a particle physics experiment with a vast physics program centered around the study of charmonium and the $\tau$ lepton. The performance of the spectrometer's inner tracker, the innermost part of a large…