Related papers: A multiball read-out for the spherical proportiona…
Spatial separation of suspended particles based on contrast in their physical or chemical properties forms the basis of various biological assays performed on lab-on-achip devices. To electronically acquire this information, we have…
We present a novel approach to measuring the expansion rate and the geometry of the Universe, which combine time-delay cosmography in lens galaxy clusters with pure samples of 'cosmic chronometers' (CCs) by probing the member galaxies. The…
We present here a simple construction of a wavelet system for the three-dimensional ball, which we label \emph{Radial 3D Needlets}. The construction envisages a data collection environment where an observer located at the centre of the ball…
Microwave Kinetic Inductance Detectors (MKID) are a promising solution for spaceborne mm-wave astronomy. To optimize their design and make them insensitive to the ballistic phonons created by cosmic-ray interactions in the substrate, the…
Two design innovations, low-gain avalanche (Low-Gain Avalance Diode, LGAD) and resistive read-out (Resistive Silicon Detector, RSD), have brought strong performance improvements to silicon sensors. Large signals, due to the added gain…
In this article the measurement results of proportional counter working characteristics filled with CF$_4$ and Xe ($0\div5$% Xe) additions at different pressures ($0.8\div14.8$ $at$) are presented. We have found that a bit of Xe addition…
Binary-outcome measurements allow to determine whether a multi-level quantum system is in a certain state while preserving quantum coherence between all orthogonal states. In this paper, we explore different regimes of the dispersive…
The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X-Y-U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using…
It is well known that a quantum correlated probe can yield better precision in estimating an unknown parameter than classically possible. However, how such a quantum probe should be measured remains somewhat elusive. We examine the role of…
The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with…
Project GRAND is an extensive air shower array of proportional wire chambers. It has 64 stations in a 100m x 100m area; each station has eight planes of proportional wire chambers with a 50 mm steel absorber plate above the bottom two…
In the ATLAS Muon Spectrometer, Monitored Drift Tube (MDT) chambers and sMDT chambers with half of the tube diameter of the MDTs are used for precision muon track reconstruction. The sMDT chambers are designed for operation at high counting…
A novel light detection scheme has been tested for use in medium-pressure gas TPCs, in view of rare events searches in low energy particle physics. It has the advantage of minimal interference with the ionization collection system, used for…
Hardware efficient methods for high fidelity quantum state measurements are crucial for superconducting qubit experiments, as qubit numbers grow and feedback and state reset begin to be employed for quantum error correction. We present a 3D…
BaF2 (Barium fluoride) detector is one of the experiment facilities at the under construction CSNS-WNS (White Neutron Source at China Spallation Neutron Source). It is designed for precisely measuring (n,gamma) cross section with total 92…
A new concept for the simultaneous detection of primary and secondary scintillation in time projection chambers is proposed. Its core element is a type of very-thick GEM structure supplied with transparent electrodes and machined from a…
In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely…
A pulse shape analysis algorithm and a method for suppressing the noise component of signals from a large copper proportional counter in the experiment aimed at searching for 2K capture of Kr-78 are described. These signals correspond to a…
A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…
We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…