Related papers: Estimating proton beam energy spread using Bragg p…
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research.…
We used the GEANT4 Monte Carlo MC Toolkit to simulate carbon ion beams incident on water, tissue, and bone, taking into account nuclear fragmentation reactions. Upon increasing the energy of the primary beam, the position of the Bragg-Peak…
Proton beam radiotherapy stands at the forefront of precision cancer treatment, leveraging the unique physical interactions of proton beams with human tissue to deliver minimal dose upon entry and deposit the therapeutic dose precisely at…
Methods: A phase space file in a plane at 202 mm downstream of the beam exit window is generated through tuning parameters to match FDC results with measured or MCNPX Monte Carlo-simulated integrated depth-dose distribution (IDD) and…
This paper characterizes the microdosimetric spectra of a single-energy carbon-ion pencil beam at MedAustron using a miniature solid-state silicon microdosimeter to estimate the impact of the lateral distribution of the different fragments…
Heavy ions have varying effects on the target. The most important factor in comparing this effect is Linear Energy Transfer (LET). Protons and carbons are heavy ions with high LET. Since these ions lose energy through collisions as they…
Purpose: To measure dispersion of a clinical proton therapy beam. Methods and Materials: The proton center at our institution uses a Hitachi PROBEAT V synchrotron that delivers beams with energies ranging from 70 to 230 MeV to five…
We have measured the total energy spread (99 persent energy spread) of the Booster beam at its injection energy of 400 MeV by three different methods - 1) creating a notch of about 40 nsec wide in the beam immediately after multiple turn…
The carbon beams show more advantages on the biological properties compared with proton beams in radiation therapy. The carbon beam shows high linear energy transfer (LET) to medium and it increases the relative biological effectiveness…
We present a practical method to measure the energy of proton beams at a medical cyclotron using the stacked foil technique in combination with a Bayesian inference method. By measuring the $^{48}$V activity induced in a stack of irradiated…
Heavy-ion therapy, particularly using scanned (active) beam delivery, provides a precise and highly conformal dose distribution, with maximum dose deposition for each pencil beam at its endpoint (Bragg peak), and low entrance and exit dose.…
We report in situ single-molecule measurements of proton-induced double-strand breaks (DSBs) in DNA immersed in water, using real-time fluorescence tracking along the entire proton path, including the Bragg peak region. By chemically…
Arrays of minibeams of protons and $^{12}$C in tissue-like media were modeled with Geant4 toolkit. A set of beam energies was used in simulations to provide a Spead-out Bragg peak (SOBP) extended by 6 cm in depth for protons as well as for…
{\bf Introduction}: To revisit the formulation of the mean chord length in microdosimetry and replace it by the particle mean free path appropriate for modelings in radio-biology. {\bf Methods}: We perform a collision-by-collision following…
Proton scattering in some water and tissue equivalent phantom materials was measured to evaluate their simulation accuracy of water and respective human biological tissues. The measurements were performed on the medical facility of the ITEP…
The thesis 'Investigations to Improve Energy Resolution for Neutron Backscattering Spectrometers Using Ideal Crystals with Low Dynamic Width of the Reflection Curve' first introduces the concept of the neutron backscattering spectrometer…
In this theoretical study, the author firstly discusses the wave interference of Bragg diffraction inside 3D crystal, followed by quantum mechanical interpretation on the diffraction process, and proves that the interference fringe between…
Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy…
For the assessment of radiation effects of clinical ion-beams, dosimetry has to be complemented by information on particle-energy distribution or related quantities. Fluorescence nuclear track detectors made from C,Mg-doped alumina single…
Multi-slat prompt-gamma camera is a promising tool for range monitoring during proton therapy. We report the results of a comprehensive simulation study analyzing the precision which is possible to reach with this camera in determination of…