Related papers: Photon Detection Using Cerium Bromide Scintillatio…
Results of experimental studies of detector arrays S-PD (scintillator-photodiode) and PRD (scintillator-photoreceiving device) used for X-ray digital radiography have shown that there exist further possibilities to increase spatial…
Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency.…
We present a new conceptual radiation detector, the Architected Multimaterial Scintillator System, that utilizes a scintillator composed of multiple materials arranged in architected structures to enable new capabilities. By structuring…
Among the top priorities for high-energy astronomy in the coming decade are sensitive surveys in the hard X-ray/soft \gamma-ray (10-600 keV) and medium-energy \gamma-ray (0.2-80 MeV) bands. Historically, observations in the soft and medium…
Using a series of detector measurements taken at different locations to localize a source of radiation is a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of…
We are developing a novel high-brightness atomic beam, comprised of a two-body exotic atom called muonium (M $ = \mu^+ + e^-$), for next-generation atomic physics and gravitational interaction measurements. This M source originates from a…
SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented…
Energy resolution and the detection efficiency for gamma quanta are fundamental properties in the construction of detectors for ionizing radiation. In this study, a SiPM-based photodetector coupled to a monolithic inorganic CeBr_{3} crystal…
The next generation of radioactive ion beam facilities, which will give experimental access to many exotic nuclei, are presently being developed. At the same time the next generation of high resolution gamma-ray spectrometers, based on…
We report on the spatial response characterization of large LaCl$_{3}$(Ce) monolithic crystals optically coupled to 8$\times$8 pixel silicon photomultiplier (SiPM) sensors. A systematic study has been carried out for 511 keV $\gamma$-rays…
The gamma to neutron ratio is measured via Pulse Shape Discrimination (PSD) of a Plutonium Beryllium (PuBe) source and of a rudimentary constructed Polonium Beryllium (PoBe) source using one organic liquid scintillator detector and digital…
The increasing volume of gamma-ray data demands new analysis approaches that can handle large-scale datasets while providing robustness for source detection. We present a Deep Learning (DL) based pipeline for detection, localization, and…
This work presents optical calculations and simulations for scintillation detectors used in precision measurements of beta-particle energy spectra. Particular attention is given to Cherenkov photons and the impact of the light detection…
High light collection efficiency is an important requirement in any application of scintillation detectors. The purpose of this study is to investigate the possibility for improving this parameter in cryogenic scintillation bolometers,…
Detection of $\gamma$-ray polarization in Positron Emission Tomography (PET) is as yet an unexploited feature that could be used as an additional handle to improve signal-to-background ratio in this imaging modality. The $\gamma$…
The sensitivity of experiments searching for neutrinoless double beta-decay of germanium was so far limited by the background induced by external gamma-radiation. Segmented germanium detectors can be used to identify photons and thus reduce…
This study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to…
The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA…
GRETA, the Gamma-Ray Energy Tracking Array, is an array of highly-segmented HPGe detectors designed to track {\gamma}-rays emitted in beam-physics experiments. Its high detection efficiency and state-of-the-art position resolution make it…
For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type.…