English
Related papers

Related papers: A custom readout electronics for the BESIII CGEM d…

200 papers

Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab.…

In this work, a fast method of vertex reconstructing for incident ions in GEM detectors was proposed. As inspired by the Time Projection Chamber (TPC), the time information of the consecutive signal samples from Front End Electronics (FEE)…

Instrumentation and Detectors · Physics 2018-12-26 Huiyin Wu , Jianjin Zhou , Herun Yang , Jianrong Zhou , Chenggui Lu , Xin Zhao , Bitao Hu , Yi Zhang

A high-precision charge measurement can be achieved by the area integration of a digitized quasi-Gaussian signal after the signal passes through the shaper and analog-to-digital converter (ADC). The charge measurement contains an error due…

Instrumentation and Detectors · Physics 2019-09-26 Jiajin Zhang , Lei Zhao , Ruoshi Dong , Peipei Deng , Cong Ma , Jiaming Lu , Shubin Liu , Qi An

The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different…

The Compressed Baryonic Matter (CBM) experiment will investigate the quantum chromodynamics (QCD) phase diagram at high net baryon densities and moderate temperatures. CBM Time of Flight (TOF) system is composed of super modules containing…

Instrumentation and Detectors · Physics 2019-01-11 Jianhui Yuan , Ping Cao , Xiru Huang , Chao Li , Qi An

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future…

Instrumentation and Methods for Astrophysics · Physics 2025-04-30 Kenneth W. Lin , Abby Bault , Armin Karcher , Julien Guy , Stephen E. Holland , William F. Kolbe , Peter E. Nugent

The use of Time Projection Chambers (TPCs) in particle physics experiments has been growing since their invention, reaching sizes equivalent to buildings (ALICE or ATLAS at CERN). However, their application in another class of experiments,…

Instrumentation and Detectors · Physics 2024-12-24 Hector Mirallas

The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X-Y-U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using…

Instrumentation and Detectors · Physics 2025-06-25 Kondo Gnanvo , Andrew Weisenberger , Seung Joon , Lee , Rui de Oliveira , Bertrand Mehl

A readout electronics used in space cosmic-ray charges measurement for multi-channel silicon detector and its performance test results are introduced in this paper. A 64-channel charge sensitive ASIC (VA140) from IDEAS company is adopt in…

Instrumentation and Detectors · Physics 2013-07-12 Zhang Fei , Fan Rui-Rui , Peng Wen-Xi , Dong Yi-Fan , Gong Ke , Liang Xiao-Hua , Liu Ya-Qing , Wang Huan-Yu

In applications with segmented high purity Ge detectors or other detector arrays with tens or hundreds of channels, where the high development cost and limited flexibility of application specific integrated circuits outweigh their benefits…

Nuclear Experiment · Physics 2009-11-13 W. Hennig , H. Tan , M. Walby , P. Grudberg , A. Fallu-Labruyere , W. K. Warburton , C. Vaman , K. Starosta , D. Miller

The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate…

Instrumentation and Detectors · Physics 2015-10-28 Kiadtisak Saenboonruang , Piyakul Kumphiranon , Kittipong Kulasri , Anawat Ritthirong

A Time Projection Chamber (TPC) using micro-pattern gas detectors is planned as the main tracking device for a detector at the next Linear Collider. A novel support structure for Gas Electron Multipliers (GEMs), which minimizes the material…

Instrumentation and Detectors · Physics 2015-06-17 T. Behnke , F. Müller , A. Münnich , K. Zenker

This project addresses the need for efficient, real-time analysis of biomedical signals such as electrocardiograms (ECG) and electroencephalograms (EEG) for continuous health monitoring. Traditional methods rely on long-duration data…

Signal Processing · Electrical Eng. & Systems 2025-04-22 Jinhai Hu

The CMS pixel detector consists of approximately 66 million silicon pixels whose analog signals are read out by 15,840 programmable Readout Chips. With the recent startup of the LHC, the detector is now collecting data used for precise…

Instrumentation and Detectors · Physics 2011-08-31 B. Kreis

CMB-S4 is the fourth-generation ground-based cosmic microwave background project, designed to probe the early universe and cosmic inflation. CMB-S4 would achieve its science goals in part by dramatically increasing the number of transition…

Motivated by the stringent requirements of the Upstream Pixel (UP) tracker in the LHCb Upgrade II and the Inner Tracking detector (ITK) of the Circular Electron Positron Collider, the COFFEE series of pixel sensor chips have been developed…

A detector emulator method has been developed. It allows for testing any readout electronics with realistic detector-like signals under controlled conditions, beyond the limits of any experiment based on radiation sources. It can substitute…

Instrumentation and Detectors · Physics 2022-03-09 Luca Moleri , Nachman Lupu , Alexander Vdovin , Enrique Kajomovitz

A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…

The recent developments in wearable devices and the Internet of Medical Things (IoMT) allow real-time monitoring and recording of electrocardiogram (ECG) signals. However, continuous monitoring of ECG signals is challenging in low-power…

Signal Processing · Electrical Eng. & Systems 2021-12-16 Berken Utku Demirel , Islam Abdelsalam Bayoumy , Mohammad Abdullah Al Faruque

The two high-angle Time Projection Chambers of the T2K experiment are equipped with a new readout system based on resistive Micromegas detector technology, and utilize custom-made electronics based on AFTER chips for signal processing. This…

‹ Prev 1 8 9 10 Next ›