Related papers: High-sensitivity Kinetic Inductance Detectors for …
The CONUS experiment is searching for coherent elastic neutrino nucleus scattering of reactor anti-neutrinos with four low energy threshold point-contact high-purity germanium spectrometers. An excellent background suppression within the…
A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is…
We describe another detectora designed for the International Linear Collider based on several tested instrumentation innovations in order to achieve the necessary experi- mental goal of a detecter that is 2-to-10 times better than the…
The last years have seen the first cryogenic detectors to be proposed for usage on balloon-borne missions. In such missions, the instrument will be exposed to the high radiation environment of the upper atmosphere. This radiation can induce…
We are developing a Lumped Element Kinetic Inductance Detector (LEKID) array able to operate in the W-band (75-110 GHz) in order to perform ground-based Cosmic Microwave Background (CMB) and mm-wave astronomical observations. The W-band is…
The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and…
The High Luminosity Large Hadron Collider (HL-LHC) will have a peak luminosity of $5\times10^{34} $cm$^{-2} $\,s$^{-1}$, five times higher than the design luminosity of the LHC. The hadronic ATLAS Tile Calorimeter TileCal) is a sampling…
The BULLKID-DM experiment aims to detect WIMP-like potential Dark Matter particles with masses below 1 GeV/c^2. Sensing these particles is challenging, as it requires nuclear recoil detectors characterized by high exposure and an energy…
We report on the optical characterization of the AlMn kinetic inductance detectors (KIDs) in development for use in the Next-generation Extended Wavelength-MUltiband Sub/millimeter Inductance Camera (NEW-MUSIC) on the Leighton Chajnantor…
The sensitivities of light Dark Matter (DM) particle searches with cryogenic detectors are mostly limited by large backgrounds of events that do not produce ionization signal. The CRYOSEL project develops a new technique where this…
The recent discovery that GaAs(Si,B) is a bright cryogenic scintillator with no apparent afterglow offers new opportunities for detecting rare, low-energy, electronic excitations from interacting dark matter. This paper presents Monte Carlo…
As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and…
The PHENIX collaboration has designed a conceptually new Hadron Blind Detector (HBD) for electron identification in high density hadron environment. The HBD will identify low momentum electron-positron pairs to reduce the combinatorial…
The basic principle of operation of silicon sensors with resistive read-out is built-in charge sharing. Resistive Silicon Detectors (RSD, also known as AC-LGAD), exploiting the signals seen on the electrodes surrounding the impact point,…
Cryogenic detectors are at the forefront of rare-event search experiments, including direct detection of dark matter, coherent elastic neutrino-nucleus scattering, neutrinoless double-beta decay, and searches for fractionally charged…
A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future International…
We demonstrate that Neganov-Luke amplified cryogenic light detectors with Transition Edge Sensor read-out can be applied for the background suppression in cryogenic experiments searching for the neutrinoless double beta decay of…
We investigate short pulse illumination of a high-speed extended-InGaAs photodiode at cryogenic temperatures towards its use in control and readout of superconducting qubits. First, we demonstrate high detector responsivity at 1550 nm…
Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…
Microwave Kinetic Inductance Detectors (MKID) are a promising solution for spaceborne mm-wave astronomy. To optimize their design and make them insensitive to the ballistic phonons created by cosmic-ray interactions in the substrate, the…