Related papers: Technical Design Report for the Panda Forward Spec…
In this study, we propose a novel fully active total absorption calorimeter with enhanced read out capabilities through fine splitting. The proposed calorimeter employs a sandwich structure composed of scintillator glasses and lead glasses,…
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The…
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced…
We propose to build the Electromagnetic calorimeter for the HADES di-lepton spectrometer. It will enable to measure the data on neutral meson production from nucleus-nucleus collisions, which are essential for interpretation of dilepton…
Recent developments on the MicroMegas prototypes built by use of the bulk technology with analog and digital readout electronics are presented. The main test beam results of a stack of several MicroMegas prototypes fully comply with the…
High precision physics at future colliders requires unprecedented highly granular calorimeters for the application of the Particle Flow (PF) algorithm. The physical proof of concept was given in the previous campaign of beam tests of physic…
The motivation for PF calorimetry is to experimentally measure the energy of hadron jets with excellent resolution. In particle flow designs, sigma(E)/E < 5% should be possible for a range of jet energies from 50 GeV to 250 GeV, important…
The ZEUS detector at HERA has been supplemented with a presampler detector in front of the forward and rear calorimeters. It consists of a segmented scintillator array read out with wavelength-shifting fibers. We discuss its desi gn,…
Future HEP experiments present stringent challenges to calorimeter materials in radiation tolerance, time response and project cost. The 2019 report of the DOE Basic Research Needs Study on High Energy Physics Detector Research and…
High channel density and space restrictions required that the front end electronics integrated into the active elements of calorimeter. For that purpose novel readout chain base on Application-Specific Integrated Circuit (ASIC) designed for…
Superconducting circuits provide a versatile and controllable platform for studies of fundamental quantum phenomena as well as for quantum technology applications. A conventional technique to read out the state of a quantum circuit or to…
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated…
Calorimetry has been a traditional tool for obtaining invaluable thermodynamic information of matter, the free energy. We describe recent efforts to go beyond this traditional calorimetry: After introducing dynamic heat capacity, we present…
This note describes R&D to be carried out on the data acquisition system for a calorimeter at the future International Linear Collider. A generic calorimeter and data acquisition system is described. Within this framework modified designs…
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated…
Realistic thermoelectric modeling and simulation tools are needed to explain the experiments and for device design. In this paper, we present a simple computational technique to make use of rigorous band structure calculations in…
The design of a wideband decimeter-wave (200 - 900 MHz) spectrometer with a magnetic induction of up to ~ 10 T is described. This spectrometer is intended for studying electronic - nuclear oscillations in antiferromagnets at low…
Detectors at future e+e- collider need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered…
In nuclear, particle and astroparticle physics experiments, calorimeters are used to measure the properties of particles with kinetic energies that range from a fraction of 1 eV to 10^20 eV or more. These properties are not necessarily…
The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons and nucleons in pi, K and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is…