Related papers: Technical Design Report for the Panda Forward Spec…
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is…
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement…
A preliminary design of the PEP-N electromagnetic calorimeter is given. The spatial,energy and time resolutions achievable using a KLOE type electromagnetic calorimeter are presented.
The subject of the thesis is the study of electromagnetic transitions in charmonium with PANDA. The possible registration of the $h_c$ state in charmonium, observed recently by the E760 and E835 Fermilab experiments, is used for…
This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…
The CALICE collaboration is involved in the design of compact calorimeters featuring a high granularity. The technical developments have to overcome various design issues such as the power dissipation, the integration of the front-end…
This paper describes an R&D electronic program for the next generation of linear collider electromagnetic calorimeter. After a brief presentation of the requirements, a global scheme of the electronics is given. Then, we describe the three…
Special calorimeters are needed to instrument the very forward region of an ILC detector. These devices will improve the hermeticity being important for new particle searches. A luminometer is foreseen to measure the rate of low angle…
The PANDA detection system at FAIR, Germany, is designed to study antiproton-proton annihilations, in order to investigate among others the realm of charm-meson states and glueballs, which has still much to reveal. The yet unknown…
There is described the design of the FODS hadron calorimeters, the procedure of the calibration and the results of the calorimeter study with electron and pion beams.
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar…
This talk reviews the development of imaging calorimeters for the purpose of applying Particle Flow Algorithms (PFAs) to the measurement of hadronic jets at a future lepton collider. After a short introduction, the current status of PFA…
This paper will argue for continued effort in developing imaging calorimeters for future colliders and/or upgrades to existing detectors. Imaging calorimeters offer a plethora of advantages beyond their application in conjunction with…
Calorimeters will provide critical measurements at future collider detectors. As the traditional challenge of high dynamic range, high precision, and high readout rates for signal amplitudes is compounded by increasing granularity and…
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking…
We present a study of a CMOS test sensor which has been designed, fabricated and characterised to investigate the parameters required for a binary readout electromagnetic calorimeter. The sensors were fabricated with several enhancements in…
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and…
A Forward Plug Calorimeter (FPC) for the ZEUS detector at HERA has been built as a shashlik lead-scintillator calorimeter with wave length shifter fiber readout. Before installation it was tested and calibrated using the X5 test beam…
A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely…
Operando calorimetry has previously been utilized to study degradation, side reactions, and other electrochemical effects in electrochemical cells such as batteries at or near room temperature. Calorimetric data can provide important…