Related papers: The Plastic Scintillator Detector at DAMPE
Experimental efforts of the last decades have been unsuccessful in detecting WIMPs (Weakly Interacting Massive Particles) in the 10-to-10$^4$ GeV/$c^2$ range, thus motivating the search for lighter dark matter. The DAMIC (DArk Matter In…
Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response…
SIMPLE 2000 (Superheated Instrument for Massive ParticLE searches) will consist of an array of eight to sixteen large active mass ($\sim15$ g) Superheated Droplet Detectors(SDDs) to be installed in the new underground laboratory of…
About $26\%$ of the matter in our Universe is made up of Dark Matter (DM), which interacts with Standard Model (SM) matter only through gravitational or weak interactions. Many proposals have been made by scientists about the possible…
This report presents an overview of the unconventional use of charge-coupled devices (CCDs) to search for Dark Matter (DM). The DArk Matter In CCDs (DAMIC Experiment) employs the bulk silicon of thick, fully-depleted CCDs as a target for…
The precise measurements of energy spectra of cosmic ray positrons and/or electrons by recent experiments show clear excesses above 10 GeV. Moreover, a potential sharp spectral feature was suggested by the Dark Matter Particle Explorer…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
The High Energy cosmic-Radiation Detection (HERD) facility is a dedicated high energy astronomy and particle physics experiment planned to be installed on the Chinese space station, aiming to detect high-energy cosmic rays (GeV $\sim$ PeV)…
For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…
Results of experimental studies of detector arrays S-PD (scintillator-photodiode) and PRD (scintillator-photoreceiving device) used for X-ray digital radiography have shown that there exist further possibilities to increase spatial…
Liquid Argon Time Projection Chambers are planned to comprise a central role in the future of the U.S. High Energy Physics neutrino program. In particular, this detector technology will form the basis for the 40 kton Deep Underground…
Direction-sensitive WIMP dark matter searches may help overcome the challenges faced by direct dark matter detection experiments. In particular, directional detectors should be able to clearly differentiate a dark matter signal from…
The Position-Sensitive Detector (PSD) for photometrical and spectral observation on the 6-meter optical telescope of the Special Astrophysical Observatory (Russia) is described. The PSD consists of a position-sensitive tube, amplifiers of…
The necessity to use Photo Multipliers (PM) as light detector limited in the past the use of crystals in radiation handled device preferring the Geiger approach. The Silicon Photomultipliers (SiPMs) are very small and cheap, solid photon…
The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment designed to mainly investigate oscillation parameters, supernova physics and proton decay. Its far detector will be composed of four liquid argon time…
The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is…
We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of…
START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs…
A monitoring system for fast neutrons is planned in the COSINE experiment, a dark matter experiment with NaI crystals. We pursued several R&D approaches for a neutron detector using a liquid scintillator (LS). A pulse shape discrimination…
The FLASH effect holds significant potential in improving radiotherapy treatment outcomes. Very high energy electrons (VHEEs) can effectively target tumors deep in the body and can be accelerated to achieve ultra-high dose rates (UHDR),…