Related papers: Performance Control of Tendon-Driven Endoscopic Su…
Tendon-sheath-driven manipulators (TSM) are widely used in minimally invasive surgical systems due to their long, thin shape, flexibility, and compliance making them easily steerable in narrow or tortuous environments. Many commercial…
Flexible endoscopic robots enable minimally invasive access through natural orifices, but their control accuracy is limited by configuration-dependent hysteresis in the tendon-sheath mechanisms (TSMs). Tendon-sheath friction and tendon…
Tendon-sheath mechanisms (TSMs) are widely used in minimally invasive surgical (MIS) applications, but their inherent hysteresis-caused by friction, backlash, and tendon elongation-leads to significant tracking errors. Conventional modeling…
Flexible tendon sheath mechanism is commonly used in NOTES systems because it offers high flexibility, light weight, and easy transmission. Due to the size constraints and sterilization problems, traditional sensors like force/torque sensor…
This paper presents a study on the backstepping control of tendon-driven continuum robots for large deflections using the Cosserat rod model. Continuum robots are known for their flexibility and adaptability, making them suitable for…
This work tackles practical issues which arise when using a tendon-driven robotic manipulator (TDRM) with a long, flexible, passive proximal section in medical applications. Tendon-driven devices are preferred in medicine for their improved…
Continuum robots have gained widespread popularity due to their inherent compliance and flexibility, particularly their adjustable levels of stiffness for various application scenarios. Despite efforts to dynamic modeling and control…
Tendon-driven continuum robots have been gaining popularity in medical applications due to their ability to curve around complex anatomical structures, potentially reducing the invasiveness of surgery. However, accurate modeling is required…
This paper presents a new task-space Non-singular Terminal Super-Twisting Sliding Mode (NT-STSM) controller with adaptive gains for robust trajectory tracking of a 7-DOF robotic manipulator. The proposed approach addresses the challenges of…
Tendon-driven continuum manipulators (TDCM) are commonly used in minimally invasive surgical systems due to their long, thin, flexible structure that is compliant in narrow or tortuous environments. There exist many researches for precise…
This paper proposes a model-based approach to control the shape of a tensegrity system by driving its node position locations. The nonlinear dynamics of the tensegrity system is used to regulate position, velocity, and acceleration to the…
Terminal sliding mode (TSM) control algorithm and its non-singular refinement have been elaborated for two decades and belong, since then, to a broader class of the finite-time controllers, which are known to be robust against the matched…
Robots with flexible spines based on tensegrity structures have potential advantages over traditional designs with rigid torsos. However, these robots can be difficult to control due to their high-dimensional nonlinear dynamics and actuator…
Transcranial magnetic stimulation (TMS) is a noninvasive medical procedure that can modulate brain activity, and it is widely used in neuroscience and neurology research. Compared to manual operators, robots may improve the outcome of TMS…
Achieving precise and efficient trajectory tracking in robotic arms remains a key challenge due to system uncertainties and chattering effects in conventional sliding mode control (SMC). This paper presents a chattering-free fast terminal…
Soft robotics is a swiftly evolving field. Pneumatic actuators are suitable for driving soft robots because of their superior performance. However, their control is challenging due to the hysteresis characteristics. In response to this…
Development of dexterous robotic joints is essential for advancing manipulation capabilities in robotic systems. This paper presents the design and implementation of a tendon-driven robotic wrist joint together with an efficient Sliding…
The ability to accurately model mechanical hysteretic behavior in tendon-actuated continuum robots using deep learning approaches is a growing area of interest. In this paper, we investigate the hysteretic response of two types of…
This paper investigates the influence of the internal geometrical structure of soft pneu-nets on the dynamic response and hysteresis of the actuators. The research findings indicate that by strategically manipulating the stress distribution…
Soft robots are robotic systems made of deformable materials and exhibit unique flexibility that can be exploited for complex environments and tasks. However, their control problem has been considered a challenging subject because they are…