English
Related papers

Related papers: Compton suppression in BEGe detectors by digital p…

200 papers

A Pixelized Photon Detector (PPD) is a generic name for the semiconductor devices operated in the Geiger-mode, such as Silicon PhotoMultiplier and Multi-Pixel Photon Counter, which has high photon counting capability. While the internal…

Instrumentation and Detectors · Physics 2009-11-13 H. Otono , H. Oide , S. Yamashita , T. Yoshioka

The ASPECT-BET (An sdd-SPECTrometer for BETa decay studies) project aims to develop a novel technique for the precise measurement of forbidden $\beta$ spectra in the 10 keV - 1 MeV range. This technique uses a Silicon Drift Detector (SDD)…

Various pulse shape discrimination methods have been used to solve the neutron-gamma discrimination problem. But most of them are limited to off-line calculation due to the computation amount and FPGA performance. In order to realize real…

Instrumentation and Detectors · Physics 2022-01-26 Haoqi Ye , Ge Jin , Lian Chen

We report on an hybrid in-beam PET and prompt-gamma Compton imaging system aimed at quasi real-time ion-range verification in proton-therapy treatments. Proof-of-concept experiments were carried out at the radiobiology beam line of the CNA…

The IGEX experiment has been operating enriched germanium detectors in the Canfranc Underground Laboratory (Spain) in a search for the neutrinoless double decay of 76Ge. The implementation of Pulse Shape Discrimination techniques to reduce…

Methods are developed, which use the pulse-height spectra of SiPMs measured in the dark and illuminated by pulsed light, to determine the pulse shape, the dark-count rate, the gain, the average number of photons initiating a Geiger…

Instrumentation and Detectors · Physics 2017-02-22 V. Chmill , E. Garutti , R. Klanner , M. Nitschke , J. Schwandt

The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense…

The emission geometries, e.g. the emission region height, the beam shape, and radius-to-frequency mapping, are important predictions of pulsar radiation model. The multi-band radio observations carry such valuable information. In this…

High Energy Astrophysical Phenomena · Physics 2017-05-31 L. H. Shang , J. G. Lu , Y. J. Du , L. F. Hao , D. Li , K. J. Lee , Bin Li , L. X. Li , G. J. Qiao , Z. Q. Shen , D. H. Wang , M. Wang , X. J. Wu , Y. J. Wu , R. X. Xu , Y. L. Yue , Z. Yan , Q. J. Zhi , R. B. Zhao , R. S. Zhao

Compared with the start-of-art energy integration detectors (EIDs), photon-counting detectors (PCDs) with energy discrimination capabilities have demonstrated great potentials in various applications of medical x-ray radiography and…

Medical Physics · Physics 2018-05-01 Ruibin Feng , David Rundle , Ge Wang

This study utilized the Tempotron, a robust classifier based on a third-generation neural network model, for pulse shape discrimination. By eliminating the need for manual feature extraction, the Tempotron model can process pulse signals…

Signal Processing · Electrical Eng. & Systems 2026-01-01 Haoran Liu , Peng Li , Ming-Zhe Liu , Kai-Ming Wang , Zhuo Zuo , Bing-Qi Liu

Background: Spectral shaping is a computed tomography (CT) dose optimization technique that adjusts source voltage and filtration to reduce patient radiation exposure without compromising image quality. Traditionally, radiation dose has…

A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated…

The Soft Gamma-ray Detector (SGD), to be deployed onboard the {\it ASTRO-H} satellite, has been developed to provide the highest sensitivity observations of celestial sources in the energy band of 60-600~keV by employing a detector concept…

We present the results of a BeppoSAX observation of PSR J0218+4232 which, for the first time, provides detailed information on the pulsar's temporal and spectral emission properties in the broad band 1-10 keV. We detected X-ray pulses with…

There are recent interests with CsI(Tl) scintillating crystals for Dark Matter experiments. The key merit is the capability to differentiate nuclear recoil (nr) signatures from the background $\beta / \gamma$-events due to ambient…

Data Analysis, Statistics and Probability · Physics 2009-11-10 S. C. Wu

Semiconductor detectors made of CdTe crystal have high gamma-ray detection efficiency and are usable at room temperature. However, the energy resolution of CdTe detectors for MeV gamma-rays is rather poor because of the significant hole…

Instrumentation and Detectors · Physics 2011-12-22 T. Kikawa , A. K. Ichikawa , T. Hiraki , T. Nakaya

This experimental particle-physics thesis reports the latest developments on the GasPM, a novel gaseous photodetector aimed at suppressing beam-induced backgrounds in the electromagnetic calorimeter for a potential upgrade of the Belle~II…

Instrumentation and Detectors · Physics 2026-05-20 Simone Garnero

Pulse compression can enhance both the performance in range resolution and sensitivity for weather radar. However, it will introduce the issue of high sidelobes if not delicately implemented. Motivated by this fact, we focus on the pulse…

Signal Processing · Electrical Eng. & Systems 2022-09-28 Linlong Wu , Mohammad Alaee-Kerahroodi , M. R. Bhavani Shankar

We present extensive simulation studies on the performance of algorithms for the Compton sequence reconstruction used for the development of a portable spectroscopic instrument (COCAE), with the capability to localize and identify…

Nuclear Experiment · Physics 2015-03-17 K. Karafasoulis , K. Zachariadou , C. Potiriadis , S. Seferlis , I. Kaissas , D. Loukas , C. Lambropoulos

Pulse pile-up in pulse-height energy analyzers increases when the incident rate of pulses increases relative to the inverse of the dead time per pulse of the detection system. Changes in the observed energy distributions with incident rate…

‹ Prev 1 3 4 5 6 7 10 Next ›