Related papers: The Muon g-2 experiment at Fermilab
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the…
The Muon g-2 Experiment (E989) at Fermilab is seeking to measure the anomalous magnetic moment of muon ($a_{\mu}$) with a precision of 140 parts-per-billion (ppb) and aiming to resolve the discrepancy between the E821 measurement and the…
The upcoming muon (g-2) experiment at Fermilab will measure the anomalous magnetic moment of the muon to a relative precision of 140 ppb, 4 times better than the previous experiment at BNL. The new experiment is motivated by the persistent…
A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at…
A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at…
The Fermilab Muon $g-2$ experiment measures the muon anomalous magnetic moment with high precision. Together with recent improvements on the theory front, the first results of the experiment confirm the long-standing discrepancy between the…
The E989 Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic anomaly, $a_\mu$, to an unprecedented precision of 140 parts per billion (ppb), representing a four-fold improvement over the current best measurement, achieved at…
The muon anomalous magnetic moment, $a_\mu = (g-2)/2$, is a low-energy observable which can be both measured and computed with very high precision, making it an excellent test of the Standard Model (SM) and a sensitive probe of new physics.…
The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
The anomalous magnetic moment (g-2) of the muon was measured with a precision of 0.54 ppm in Experiment 821 at Brookhaven National Laboratory. A difference of 3.2 standard deviations between this experimental value and the prediction of the…
The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
The New Muon $(g-2)$ Collaboration at Fermilab has proposed to measure the anomalous magnetic moment of the muon, $a_\mu$, a factor of four better than was done in E821 at the Brookhaven AGS, which obtained $a_\mu = [116 592 089 (63)]…
A new experiment at Fermilab will measure the anomalous magnetic moment of the muon with a precision of 140 parts per billion (ppb). This measurement is motivated by the results of the Brookhaven E821 experiment that were first released…
The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was…
I report on the progress of two new muon anomalous magnetic moment experiments, which are in advanced design and construction phases. The goal of Fermilab E989 is to reduce the experimental uncertainty of $a_\mu$ from Brookhaven E821 by a…
The current $\sim3.5\sigma$ discrepancy between the experimental measurement and theoretical prediction of the muon magnetic anomaly, $a_{\mu}$, stands as a potential indication of the existence of new physics. The Muon $g-2$ experiment at…
The Muon g-2 experiment at Fermilab seeks to measure the muon magnetic moment anomaly, $a_\mu =(g-2)/2$, with a final target precision of 0.14 parts-per-million (ppm). The experiment's initial result, published in 2021 using Run 1 data from…
The magnetic moment is a fundamental property of particles. The measurement of these magnetic moments and the comparison with the values predicted by the standard model of particle physics is a way to test our understanding of the…
The muon (g-2) experiment at BNL has completed four data runs for the positive muon, beginning in 1997 and has just finished its first run for the negative muon. Recently the analysis of a 1.3 ppm result based on the 1999 run was completed…
The Muon (g-2) Experiment (E821) at Brookhaven National Laboratory (BNL) has measured the anomalous magnetic moment of the positive muon to an unprecedented precision of 1.3 parts per million. The result, a_{\mu^+} = (g-2)/2 = 11 659…