Related papers: Microscopic Muscle Image Enhancement
Image denoising is a fundamental challenge in computer vision, with applications in photography and medical imaging. While deep learning-based methods have shown remarkable success, their reliance on specific noise distributions limits…
State-of-the-art algorithms for many semantic visual tasks are based on the use of convolutional neural networks. These networks are commonly trained, and evaluated, on large annotated datasets of artifact-free high-quality images. In this…
Most of the classical denoising methods restore clear results by selecting and averaging pixels in the noisy input. Instead of relying on hand-crafted selecting and averaging strategies, we propose to explicitly learn this process with deep…
Blind deconvolution is an ill-posed problem arising in various fields ranging from microscopy to astronomy. The ill-posed nature of the problem requires adequate priors to arrive to a desirable solution. Recently, it has been shown that…
Endoscopy is a routine imaging technique used for both diagnosis and minimally invasive surgical treatment. Artifacts such as motion blur, bubbles, specular reflections, floating objects and pixel saturation impede the visual interpretation…
Denoising is a fundamental imaging problem. Versatile but fast filtering has been demanded for mobile camera systems. We present an approach to multiscale filtering which allows real-time applications on low-powered devices. The key idea is…
Magnetic resonance imaging (MRI) is one of the noninvasive imaging modalities that can produce high-quality images. However, the scan procedure is relatively slow, which causes patient discomfort and motion artifacts in images. Accelerating…
Moving objects are frequently seen in daily life and usually appear blurred in images due to their motion. While general object retrieval is a widely explored area in computer vision, it primarily focuses on sharp and static objects, and…
Most motion deblurring algorithms rely on spatial-domain convolution models, which struggle with the complex, non-linear blur arising from camera shake and object motion. In contrast, we propose a novel single-image deblurring approach that…
Over the past decade, reflection matrix microscopy (RMM) and advanced image reconstruction algorithms have emerged to address the fundamental imaging depth limitations of optical microscopy in thick biological tissues and complex media. In…
Image smoothing is a fundamental procedure in applications of both computer vision and graphics. The required smoothing properties can be different or even contradictive among different tasks. Nevertheless, the inherent smoothing nature of…
As an integral component of blind image deblurring, non-blind deconvolution removes image blur with a given blur kernel, which is essential but difficult due to the ill-posed nature of the inverse problem. The predominant approach is based…
In low light or short-exposure photography the image is often corrupted by noise. While longer exposure helps reduce the noise, it can produce blurry results due to the object and camera motion. The reconstruction of a noise-less image is…
In computer-aided diagnosis (CAD) focused on microscopy, denoising improves the quality of image analysis. In general, the accuracy of this process may depend both on the experience of the microscopist and on the equipment sensitivity and…
Blind deconvolution and demixing is the problem of reconstructing convolved signals and kernels from the sum of their convolutions. This problem arises in many applications, such as blind MIMO. This work presents a separable approach to…
This paper proposes a novel approach to image deblurring and digital zooming using sparse local models of image appearance. These models, where small image patches are represented as linear combinations of a few elements drawn from some…
Turbulence-degraded image frames are distorted by both turbulent deformations and space-time-varying blurs. To suppress these effects, we propose a multi-frame reconstruction scheme to recover a latent image from the observed image…
Bias field, which is caused by imperfect MR devices or imaged objects, introduces intensity inhomogeneity into MR images and degrades the performance of MR image analysis methods. Many retrospective algorithms were developed to facilitate…
This paper proposes a novel approach to regularize the \textit{ill-posed} and \textit{non-linear} blind image deconvolution (blind deblurring) using deep generative networks as priors. We employ two separate generative models --- one…
Typical blur from camera shake often deviates from the standard uniform convolutional script, in part because of problematic rotations which create greater blurring away from some unknown center point. Consequently, successful blind…