English
Related papers

Related papers: Measurement Of Energy Resolution For TES Microcalo…

200 papers

We characterised a TES-based X-ray microcalorimeter in an adiabatic demagnetisation refrigerator (ADR) using synchrotron radiation. The detector response and energy resolution was measured at the beam-line in the PTB radiometry laboratory…

Optical transition-edge sensors have shown energy resolution for resolving the number of incident photons at the telecommunication wavelength. Higher energy resolution is required for biological imaging and microscope spectroscopy. In this…

Instrumentation and Detectors · Physics 2022-07-27 Kaori Hattori , Toshio Konno , Yoshitaka Miura , Sachiko Takasu , Daiji Fukuda

The superconducting Transition-Edge Sensor (TES) is a critical technology for next-generation X-ray spectrometers, known for its exceptional energy resolution. In the last decade, TESs based on AlMn alloy films have been extensively used in…

Instrumentation and Methods for Astrophysics · Physics 2026-02-13 Liangpeng Xie , Yifei Zhang , Zhengwei Li , Zhouhui Liu , Shibo Shu , Junjie Zhou , Xufang Li , Haoyu Li , He Gao , Yudong Gu , Xuefeng Lu , Yong Zhao , Congzhan Liu

Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $\Delta E$ < 3 eV full-width-half-maximum (FWHM) in the soft…

Instrumentation and Methods for Astrophysics · Physics 2021-02-19 E. Taralli , M. D'Andrea , L. Gottardi , K. Nagayoshi , M. L. Ridder , M. de Wit , D. Vaccaro , H. Akamatsu , M. P. Bruijn , J. R. Gao

We present the first detection of electrons with kinetic energy in the 100 eV range with transition-edge sensors (TESs). This has been achieved with a $(100\times 100)$ $\mu$m$^2$ Ti-Au bilayer TES, with a critical temperature of about 84…

Superconducting transition-edge sensors (TES) are extremely sensitive microcalorimeters used as photon detectors with unparalleled energy resolution. They have found application from measuring astronomical spectra through to determining the…

A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to…

Instrumentation and Detectors · Physics 2008-11-26 M. Aharrouche , ATLAS Electromagnetic Barrel Calorimeter Collaboration

We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDMconfiguration the TES is AC voltage biased at a well defined frequencies (between…

Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…

Instrumentation and Methods for Astrophysics · Physics 2017-02-03 J. W. Fowler , B. K. Alpert , W. B. Doriese , D. A. Fischer , C. Jaye , Y. I. Joe , G. C. O'Neil , D. S. Swetz , J. N. Ullom

Transition Edge Sensors (TESs) are characterized by the intrinsic figure of merit to resolve both the energy and the statistical distribution of the incident photons. These properties lead TES devices to become the best single photon…

Instrumentation and Detectors · Physics 2013-06-25 L. Lolli , E. Taralli , C. Portesi , E. Monticone , M. Rajteri

A 57Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition if a hypothetical elementary particle, axion, exists to solve the strong CP problem. Transition edge sensor (TES) X-ray microcalorimeters…

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this…

Semiconductor detectors made of CdTe crystal have high gamma-ray detection efficiency and are usable at room temperature. However, the energy resolution of CdTe detectors for MeV gamma-rays is rather poor because of the significant hole…

Instrumentation and Detectors · Physics 2011-12-22 T. Kikawa , A. K. Ichikawa , T. Hiraki , T. Nakaya

The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with…

High Energy Physics - Experiment · Physics 2013-10-07 CMS Collaboration

The state-of-the-art technology of X-ray microcalorimeters based on superconducting transition edge sensors (TESs), for applications in astrophysics and particle physics, is reviewed. We will show the advance in understanding the detector…

Instrumentation and Methods for Astrophysics · Physics 2022-10-14 Luciano Gottardi , Kenichiro Nagayoshi

At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in an AC bias configuration. For x-ray photons at 6 keV the pixel shows an x-ray energy resolution $dE_{FWHM} =…

We report measurements of the energy resolution of ultra-sensitive superconducting bolometric detectors. The device is a superconducting titanium nanobridge with niobium contacts. A fast microwave pulse is used to simulate a single…

Superconducting transition-edge sensors (TESs) carried by X-ray telescopes are powerful tools for the study of neutron stars and black holes. Several methods, such as optimal filtering or principal component analysis, have already been…

Instrumentation and Methods for Astrophysics · Physics 2021-04-12 Paul Ripoche , Jeremy Heyl

If a hypothetical elementary particle called an axion exists, to solve the strong CP problem, a 57Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition. If such axions are once more transformed…

Instrumentation and Methods for Astrophysics · Physics 2023-04-20 Yuta Yagi , Tasuku Hayashi , Keita Tanaka , Rikuta Miyagawa , Ryo Ota , Noriko Y. Yamasaki , Kazuhisa Mitsuda , Nao Yoshida , Mikiko Saito , Takayuki Homma
‹ Prev 1 2 3 10 Next ›