English
Related papers

Related papers: Tiny adiabatic-demagnetization refrigerator for a …

200 papers

Optically pumped magnetometers are becoming a promising alternative to cryogenically-cooled superconducting magnetometers for detecting and imaging biomagnetic fields. Magnetic field detection is a completely non-invasive method, which…

We present measurements of the electron temperature using gate defined quantum dots formed in a GaAs 2D electron gas in both direct transport and charge sensing mode. Decent agreement with the refrigerator temperature was observed over a…

Mesoscale and Nanoscale Physics · Physics 2015-09-08 D. Maradan , L. Casparis , T. -M. Liu , D. E. F. Biesinger , C. P. Scheller , D. M. Zumbühl , J. Zimmerman , A. C. Gossard

We propose a solid state refrigeration technique based on repeated adiabatic magnetization/demagnetization cycles of a superconductor which acts as the working substance. The gradual cooling down of a substrate (normal metal) in contact…

Superconductivity · Physics 2019-05-14 Sreenath K. Manikandan , Francesco Giazotto , Andrew N. Jordan

Low-temperature refrigeration is of crucial importance in fundamental research of condensed matter physics, as the investigations of fascinating quantum phenomena, such as superconductivity, superfluidity and quantum criticality, often…

Strongly Correlated Electrons · Physics 2016-09-14 Y. Tokiwa , B. Piening , H. S. Jeevan , S. L. Bud'ko , P. C. Canfield , P. Gegenwart

An atomic magnetometer operated with elliptically polarized light is investigated theoretically and experimentally. To explore the potential of this magnetometric configuration, the analytical form of the outgoing signal is derived.…

Atomic Physics · Physics 2020-01-08 Shengran Su , Guoyi Zhang , Xin Bi , Xiang He , Wenqiang Zheng , Qiang Lin

$\beta$-YbAlB$_4$ is the first Yb-based heavy fermion superconductor with $T_{\rm c} = 80$ mK. We measured low temperature magnetization of high-purity single crystals down to $T=$ 25 mK. The measurements have revealed a considerable amount…

Strongly Correlated Electrons · Physics 2015-10-28 Y. Matsumoto , K. Kuga , Y. Karaki , T. Tomita , S. Nakatsuji

An instrument has been constructed to measure a large range of magnetostriction and thermal expansion between room temperature and 4 K in a superconductive split-coil magnet, that allows investigation in magnetic fields up to 12 T. The very…

Materials Science · Physics 2015-05-14 B. Kundys , Yu. Bukhantsev , S. Vasiliev , D. Kundys , M. Berkowski , V. P. Dyakonov

Rare-earth (RE) based frustrated magnets have attracted great attention as excellent candidates for magnetic refrigeration at sub-Kelvin temperatures, while the experimental identification on systems exhibiting both large volumetric cooling…

Magnetic refrigeration at room temperature is of great interest due to a long-term goal of making refrigeration more energy-efficient, less noisy and free of any environmentally hostile materials. A refrigerator utilizing an active magnetic…

Materials Science · Physics 2012-09-19 K. K. Nielsen , R. Bjoerk , J. B. Jensen , C. R. H Bahl , N. Pryds , A. Smith , A. Nordentoft , J. Hattel

We measured the vibration of a prototype superconducting magnetic bearing (SMB) operating at liquid nitrogen temperature. This prototype system was designed as a breadboard model for LiteBIRD low-frequency telescope (LFT) polarization…

The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here we describe several component technologies and a laser system…

Systematically magnetic and magnetothermal measurements at temperatures down to 2 K and magnetic fields up to 13.5 Tesla for Gd(OH)3 Single Crystal Nanowires - Quasi-1D Large Spin (S = -7/2) Chain Antiferromagnet have been conducted. We…

Materials Science · Physics 2012-07-16 R. Zeng , C. F. Zhang , J. C. Debnath , P. Shamba , J. L. Wang , Z. X. Chen , Z. P. Guo , S. X. Dou

Microwave impedance microscopy (MIM) is a near-field imaging technique that has been used to visualize the local conductivity of materials with nanoscale resolution across the GHz regime. In recent years, MIM has shown great promise for the…

Applied Physics · Physics 2023-10-03 Leonard Weihao Cao , Chen Wu , Rajarshi Bhattacharyya , Ruolun Zhang , Monica T. Allen

We report magnetic measurements up to 1100 K on a multi-walled carbon nanotube mat sample using a Quantum Design vibrating sample magnetometer. In an ultra-low field (H = -0.02 Oe), we find a very large paramagnetic susceptibility (up to…

Superconductivity · Physics 2007-05-23 Guo-meng Zhao , Pieder Beeli

Van der Waals magnetic materials are an ideal platform to study low-dimensional magnetism. Opposed to other members of this family, the magnetic semiconductor CrSBr is highly resistant to degradation in air, which, besides its exceptional…

A miniature opposed-anvil high-pressure cell has been developed for magnetic measurement in a commercial superconducting quantum interference device (SQUID) magnetometer. Non-magnetic anvils made of composite ceramic material were used to…

Strongly Correlated Electrons · Physics 2015-05-28 Naoyuki Tateiwa , Yoshinori Haga , Zachary Fisk , Yoshichika Onuki

Progress in electromagnetic induction imaging with atomic magnetometers has brought its domain to the edge of the regime useful for biomedical imaging. However, a demonstration of imaging below the required 1 Sm$^{-1}$ level is still…

Instrumentation and Detectors · Physics 2020-04-02 Cameron Deans , Luca Marmugi , Ferruccio Renzoni

This paper presents a three-stage continuous adiabatic demagnetization refrigerator (CADR) simultaneously providing cooling platforms at two different temperatures. Unlike conventional CADR with two continuous stages, this system does not…

Instrumentation and Methods for Astrophysics · Physics 2026-02-11 Yanan Li , Ke Li , Teng Pan , Yaxuan Wang , Wei Dai

We present the design and implementation of a scanning probe microscope, which combines electrically detected magnetic resonance (EDMR) and (photo-)conductive atomic force microscopy ((p)cAFM). The integration of a 3-loop 2-gap X-band…

The magnetic properties of dilute magnetic semiconductors (DMS) are calculated from first-principles by mapping the ab initio results on a classical Heisenberg model. It is found that the range of the exchange interaction in (Ga, Mn)N is…

Materials Science · Physics 2007-05-23 K. Sato , W. Schweika , P. H. Dederichs , H. Katayama-Yoshida
‹ Prev 1 3 4 5 6 7 10 Next ›