Related papers: Use of Feedback to Maximize Photon Count Rate in X…
X-ray is a ubiquitous imaging modality in clinical diagnostics and industrial inspections, thanks to its high penetration power. Conventional x-ray imaging system, equipped with energy-integrating detectors, collects approximately 1000 to…
The spectroscopic performance of x-ray instruments can be affected at high count rates. The effects and mitigation in the optical chain, such as x-ray attenuation filters or de-focusing mirrors, are widely discussed, but those in the signal…
X-ray free electron laser (XFEL) can provide X-ray light with about four order of magnitude higher flux than synchrotron radiation. Pulse light from XFEL interacts with the target and the resulting photons are collected by detectors. The…
This paper proposes a method for estimating and detecting optical signals in practical photon-counting receivers. There are two important aspects of non-perfect photon-counting receivers, namely, (i) dead time which results in blocking…
A formalism for treating the pile-up produced in solid-state detectors by laser-driven pulsed x-ray sources has been developed. It allows the direct use of x-ray spectroscopy without artificially decreasing the number of counts in the…
We report experimental observations of correlated-photon statistics in the single-photon detection rate. The usual quantum interference in a two-photon polarization interferometer always accompanies a dip in the single detector counting…
Macro x-ray fluorescence (XRF) imaging of cultural heritage objects, while a popular non-invasive technique for providing elemental distribution maps, is a slow acquisition process in acquiring high signal-to-noise ratio XRF volumes.…
In order to discern aggregation in solutions, we present a quantum mechanical analog of the photon statistics from fluorescent molecules diffusing through a focused beam. A generating functional is developed to fully describe the…
Frequency-filtered photon correlations have been proven to be extremely useful in grasping how the detection process alters photon statistics. Harnessing the spectral correlations also permits refinement of the emission and unraveling of…
Spectral filtering of resonance fluorescence is widely employed to improve single photon purity and indistinguishability by removing unwanted backgrounds. For filter bandwidths approaching the emitter linewidth, complex behaviour is…
Detection of radiation signals is at the heart of precision metrology and sensing. In this article we show how the fluctuations in photon counting signals can be exploited to optimally extract information about the physical parameters that…
The probability of photon measurement in some photon counting instrumentation, such as the Optical Monitor on the XMM-Newton satellite, and the UVOT on the Swift satellite, does not follow a Poisson distribution due to the detector…
In the evaluation of novel scintillators, it is important to ensure that the spectrum of the light emitted by the scintillator is well matched to the response of the photomultiplier. In attempting to measure this spectrum using radioactive…
We present a scheme for a photon-counting detection system that can be operated at incident photon rates higher than otherwise possible by suppressing the effects of detector deadtime. The method uses an array of N detectors and a 1-by-N…
-In the Alvarez-Macovski method [R.E. Alvarez and A. Macovski, Phys. Med. Biol., 1976, 733-744], the attenuation coefficient is approximated as a linear combination of functions of energy multiplied by coefficients that depend on the…
We consider the counting rate estimation of an unknown radioactive source, which emits photons at times modeled by an homogeneous Poisson process. A spectrometer converts the energy of incoming photons into electrical pulses, whose number…
We present calculations of the time lags and the coherence function of X-ray photons for a novel model of radiation emission from accretion powered, high-energy sources. Our model involves only Comptonization of soft photons injected near…
Modern X-ray and gamma-ray observatories time-tag detected photons. The distribution of intervals between successive photons may reveal variations of the flux on time scales too short for direct flux measurement of the mean count rate,…
The applicability of LaBr3:Ce detectors for high count rate {\gamma}-ray spectroscopy is investigated. A 3"x3" LaBr3:Ce detector is used in a test setup with radioactive sources to study the dependence of energy resolution and photo peak…