Related papers: Improved noninterferometric test of collapse model…
We have analyzed recently published XENONnT data for the spontaneous X-ray emission signature predicted by the objective wave function collapse model of quantum mechanics. With extremely low background and large exposure, XENONnT data can…
Collapse models postulate that space is filled with a collapse noise field, inducing quantum Brownian motions which are dominant during the measurement, thus causing collapse of the wave function. An important manifestation of collapse…
Non-interferometric experiments have been successfully employed to constrain models of spontaneous wave function collapse, which predict a violation of the quantum superposition principle for large systems. These experiments are grounded on…
Heating induced by the noise postulated in wave function collapse models leads to a lower bound to the temperature of solid objects. For the noise parameter values $\lambda ={\rm coupling~strength}\sim 10^{-8} {\rm s}^{-1}$ and $r_C ={\rm…
The Continuous Spontaneous Localization (CSL) model is an alternative formulation of quantum mechanics which introduces a noise coupled non linearly to the wave function to account for its collapse. We consider CSL effects on quantum…
Spontaneous wavefunction collapse theories provide the possibility to resolve the measurement problem of quantum mechanics. However, the best experimental tests have been limited by thermal fluctuations and have operated at frequencies far…
Collapse models constitute an alternative to quantum mechanics that solve the well-know quantum measurement problem. In this framework, a novel approach to include dissipation in collapse models has been recently proposed, and awaits…
Atomic force microscopy cantilevers are often, intentionally or not, heated at their extremity. We describe a model to compute the resulting temperature field in the cantilever and in the surrounding fluid on a wide temperature range. In…
The displacement of micro-electro-mechanical-systems (MEMS) cantilevers is used to measure a broad variety of phenomena in devices ranging from force microscopes to biochemical sensors to thermal imaging systems. We demonstrate the first…
We present experimental tests of dissipative extensions of spontaneous wave function collapse models based on a levitated micromagnet with ultralow dissipation. The spherical micromagnet, with radius $R=27$ $\mu$m, is levitated by Meissner…
Aligning a microcantilever to an area of interest on a sample is a critical step in many scanning probe microscopy experiments, particularly those carried out on devices and rare, precious samples. We report a series of protocols that…
We cool the fundamental mechanical mode of an ultrasoft silicon cantilever from a base temperature of 2.2 K to 2.9 +/- 0.3 mK using active optomechanical feedback. The lowest observed mode temperature is consistent with limits determined by…
Measuring very small forces, particularly those of a gravitational nature, has always been of great interest, as fundamental tests of our understanding of the physical laws. Ultra-long period mechanical oscillators, typically used in such…
The continuous spontaneous localization (CSL) model is one of the most promising approaches to address the wave function collapse problem in the measurement process of standard quantum mechanics. In this work, the effect of the CSL model on…
We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres…
We describe a transducer for low-temperature atomic force microscopy based on electromechanical coupling due to a strain-dependent kinetic inductance of a superconducting nanowire. The force sensor is a bending triangular plate (cantilever)…
Collapse models postulate the existence of intrinsic noise which modifies quantum mechanics and is responsible for the emergence of macroscopic classicality. Assessing the validity of these models is extremely challenging because it is…
Here we find the increase in 1/f noise of superconducting resonators at low temperatures to be completely incompatible with the standard tunneling model (STM) of Two Level Systems (TLS), which has been used to describe low-frequency noise…
Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonics noise caused by the mechanical coolers is a general and inherent issue for these…
When heated, micro-resonators present a shift of their resonance frequencies. We study specifically silicon cantilevers heated locally by laser absorption, and evaluate theoretically and experimentally their temperature profile and its…