English
Related papers

Related papers: Behavior of a trapezoid-based data acquisition sys…

200 papers

Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. This article describes the details of the custom designed GRIFFIN…

Following work done in the energy region above 100 keV, the high-precision calibration of a co-axial high-purity germanium detector has been continued in the energy region below 100 keV. Previous measurements or Monte-Carlo simulations have…

Instrumentation and Detectors · Physics 2020-04-08 B. Blank , P. Ascher , M. Gerbaux , J. Giovinazzo , S. Grevy , T. Kurtukian Nieto , M. Versteegen , J. C. Thomas

The performance of germanium detectors for high-energy $\gamma$-rays was evaluated using a 992-keV resonance in the $^{27}$Al(p, $\gamma$)$^{27}$Si reaction. The measurement was conducted at the RIKEN tandem accelerator. The energy of the…

The Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. The performance of the 16 high-purity germanium (HPGe) clover…

We compare the observed strong saturation of the free carrier absorption in n-type semiconductors at 300 K in the terahertz frequency range when single-cycle pulses with intensities up to 150 MW/cm2 are used. In the case of germanium, a…

Materials Science · Physics 2015-05-13 Janos Hebling , Matthias C. Hoffmann , Harold Y. Hwang , Ka-Lo Yeh , Keith A. Nelson

We describe here an efficient machine-learning based approach for the optimization of parameters used for extracting the arrival time of waveforms, in particular those generated by the detection of 511 keV annihilation gamma-rays by a 60…

Instrumentation and Detectors · Physics 2020-04-02 R. W. Gladen , V. A. Chirayath , A. J. Fairchild , M. T. Manry , A. R. Koymen , A. H. Weiss

Charge trapping degrades the energy resolution of germanium (Ge) detectors, which require to have increased experimental sensitivity in searching for dark matter and neutrinoless double-beta decay. We investigate the charge trapping…

We achieve high detectivity terahertz sensing using a silicon nitride nanomechanical resonator functionalized with a metasurface absorber. High performances are achieved by striking a fine balance between the frequency stability of the…

Ultrafast and sensitive (noise equivalent power <1 nWHz-1/2) light-detection in the Terahertz (THz) frequency range (0.1-10 THz) and at room-temperature is key for applications such as time-resolved THz spectroscopy of gases, complex…

A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+…

A high-purity co-axial germanium detector has been calibrated in efficiency to a precision of about 0.15% over a wide energy range. High-precision scans of the detector crystal and gamma-ray source measurements have been compared to…

We present measurements of electron and hole trapping in three COSI germanium cross-strip detectors. By characterizing the relative charge collection efficiency (CCE) as a function of interaction depth, we show that intrinsic trapping of…

Instrumentation and Detectors · Physics 2023-10-26 Sean N. Pike , Steven E. Boggs , Jacqueline Beechert , Jarred Roberts , Albert Y. Shih , John A. Tomsick , Andreas Zoglauer

With present-day detectors in high energy physics one often faces fast analog pulses of a few nanoseconds length which cover large dynamic ranges. In many experiments both amplitude and timing information have to be measured with high…

``Oversimplified'' and ``simplified'' methods based on true coincidence summing effect used in uncomplicated determination of the photo-peak efficiency of the semiconductor High Purity Germanium (HPGe) detector system are suggested and…

Instrumentation and Detectors · Physics 2022-06-22 Victor V. Golovko

The use of High Purity Germanium detectors operated in ionization mode at cryogenic temperatures is investigated as an external background mitigation solution for bolometers used in rare-event search experiments. A simple experimental setup…

High Energy Physics - Experiment · Physics 2025-09-05 Chloé Goupy , Stefanos Marnieros , Beatrice Mauri , Claudia Nones , Matthieu Vivier

A study on cosmogenic activation in germanium was carried out to evaluate the cosmogenic background level of natural and $^{70}$Ge depleted germanium detectors. The production rates of long-lived radionuclides were calculated with Geant4…

Instrumentation and Detectors · Physics 2018-10-23 J. L. Ma , Q. Yue , S. T. Lin , H. T. Wong , J. W. Hu , L. P. Jia , H. Jiang , J. Li , S. K. Liu , Z. Z. Liu , H. Ma , W. Y. Tang , Y. Tian , L. Wang , Q. Wang , L. T. Yang , Z. Zeng

Charge trapping in germanium detectors will inevitably impact their excellent spectral performance. Disordered regions in the germanium crystal structure, either created in the material during processing or induced by radiation exposure,…

Instrumentation and Detectors · Physics 2023-10-03 Steven E. Boggs , Sean N. Pike

In order to understand the performance of the PARIS (Photon Array for the studies with Radioactive Ion and Stable beams) detector, detailed characterization of two individual phoswich (LaBr$_3$(Ce)-NaI(Tl)) elements has been carried out.…

The Nab experiment will measure the electron-neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model Physics. Using National Instrument's PXIe-5171…

‹ Prev 1 2 3 10 Next ›