Related papers: The muon g-2 experiment at Fermilab
The Fermi National Accelerator Laboratory (FNAL) Muon $g-2$ Experiment has measured the positive muon magnetic anomaly $a_{\mu} \equiv (g_{\mu}-2)/2$ with a precision of 0.46 parts per million, with data collected during its first physics…
We present the final report from a series of precision measurements of the muon anomalous magnetic moment, a_mu = (g-2)/2. The details of the experimental method, apparatus, data taking, and analysis are summarized. Data obtained at…
A higher precision measurement of the anomalous g value, a_mu = (g-2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron, based on data collected in the year 2000. The result a_{mu^+} = 11 659…
The very precise measurement of the anomalous magnetic moment of the muon, recently released by the Muon g-2 experiment at Fermilab, can serve to set stringent constraints on new particles. If the observed 4$\sigma$ discrepancy from the…
A precise measurement of the anomalous g value, a_mu=(g-2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron. The result a_mu^+=11 659 202(14)(6) X 10^{-10} (1.3 ppm) is in good agreement with…
The Muon g-2 experiment E989 at Fermilab measures the anomalous magnetic moment of the muon $a_\mu$ with improved precision compared to the Brookhaven (E821) experiments. The Brookhaven results are in tension with the Standard Model by more…
The anomalous magnetic moment of the muon has been measured to 0.5 ppm in a series of precision experiments at the Brookhaven Alternating Gradient Synchrotron. The individual results for each sign: a(mu+)= 11 659 204(7)(5) E-10 and a(mu-) =…
The new g-2 experiment at Fermilab aims to measure the muon anomalous magnetic moment by a fourfold improvement in precision compared to the BNL experiment. Achieving this goal requires the delivery of highly polarized 3.094 GeV/c muons…
The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab has a goal of measuring the muon anomaly ($a_\mu$) with unprecedented precision using positive muons. This measurement is motivated by the difference between the previous Brookhaven…
We propose a next-generation precision measurement of the muon anomalous magnetic moment (muon $g-2$), at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in China. The project, named CANTON-$\mu$ (Coherent Anomalous magNetic momenT…
The E821 experiment at Brookhaven National Laboratory is designed to measure the muon magnetic anomaly, a_mu, to an ultimate precision of 0.4 parts per million (ppm). Because theory can predict a_mu to 0.6 ppm, and ongoing efforts aim to…
The magnetic moment is a fundamental property of particles. The measurement of these magnetic moments and the comparison with the values predicted by the standard model of particle physics is a way to test our understanding of the…
I report on the progress of two new muon anomalous magnetic moment experiments, which are in advanced design and construction phases. The goal of Fermilab E989 is to reduce the experimental uncertainty of $a_\mu$ from Brookhaven E821 by a…
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_\mu = (g^{}_\mu-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018.…
The Fermilab Muon $g-2$ experiment recently reported its first measurement of the anomalous magnetic moment $a_\mu^{\textrm{FNAL}}$, which is in full agreement with the previous BNL measurement and pushes the world average deviation $\Delta…
The longstanding discrepancy between the measured and the predicted values of the anomalous magnetic moment of the muon, $a_\mu = (g-2)/2$, is one of the most intriguing potential hints of new physics in particle physics. After a brief…
Recently, the Muon g-2 experiment at Fermilab has measured the muon anomalous magnetic dipole moment (MDM), $a_\mu=(g_\mu-2)/2$, which reported that the new experimental average increases the tension between experiment and the standard…
A new measurement of the muon anomalous magnetic moment has been reported by the Fermilab Muon g-2 collaboration and shows a $4.2\sigma$ departure from the most precise and reliable calculation of this quantity in the Standard Model.…
The muon g-2 collaboration has measured the anomalous magnetic g value of the positive muon to within a relative uncertainty of 0.7 parts per million. The result, a_{\mu^+} = 11 659 204(7)(5) x 10^{-10} is in good agreement with the…
The muon anomalous magnetic moment is one of the most precisely measured quantities in particle physics. Recent high precision measurements (0.54ppm) at Brookhaven reveal a ``discrepancy'' by 3 standard deviations from the electroweak…