English
Related papers

Related papers: Radon depletion in xenon boil-off gas

200 papers

We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon…

Instrumentation and Detectors · Physics 2017-06-05 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. Le Calloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , I. Cristescu

The XENONnT experiment has achieved an exceptionally low $^\text{222}$Rn activity concentration within its inner 5.9$\,$tonne liquid xenon detector of (0.90$\,\pm\,$0.01$\,$stat.$\,\pm\,$0.07 sys.)$\,\mu$Bq/kg, equivalent to about 430…

Instrumentation and Detectors · Physics 2025-04-28 E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , D. Antón Martin , F. Arneodo , L. Baudis , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , K. Boese , A. Brown , G. Bruno , R. Budnik , C. Cai , C. Capelli , J. M. R. Cardoso , A. P. Cimental Chávez , A. P. Colijn , J. Conrad , J. J. Cuenca-García , V. D'Andrea , L. C. Daniel Garcia , M. P. Decowski , A. Deisting , C. Di Donato , P. Di Gangi , S. Diglio , K. Eitel , S. el Morabit , A. Elykov , A. D. Ferella , C. Ferrari , H. Fischer , T. Flehmke , M. Flierman , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , M. Galloway , F. Gao , S. Ghosh , R. Giacomobono , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guida , P. Gyorgy , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , Y. Kaminaga , M. Kara , P. Kavrigin , S. Kazama , P. Kharbanda , M. Kobayashi , D. Koke , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , Z. Liang , Y. -T. Lin , S. Lindemann , M. Lindner , K. Liu , M. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , T. Luce , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , E. Masson , S. Mastroianni , A. Melchiorre , J. Merz , M. Messina , A. Michael , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , Y. Pan , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , L. Principe , J. Qi , J. Qin , D. Ramírez García , M. Rajado , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , D. Schulte , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , J. Shi , M. Silva , H. Simgen , C. Szyszka , A. Takeda , Y. Takeuchi , P. -L. Tan , D. Thers , F. Toschi , G. Trinchero , C. D. Tunnell , F. Tönnies , K. Valerius , S. Vecchi , S. Vetter , F. I. Villazon Solar , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong

A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT…

Instrumentation and Detectors · Physics 2022-12-28 M. Murra , D. Schulte , C. Huhmann , C. Weinheimer

The PandaX-4T distillation system, designed for the removal of krypton and radon from xenon, is evaluated for its radon removal efficiency using a $^{222}$Rn source during the online distillation process. The PandaX-4T dark matter detector…

We construct a high sensitivity radon pilot detector using liquid scintillator dissolved radon for the CDEX rare-event searches program. The CDEX-10 project employs a germanium detector array immersed in a massive liquid nitrogen tank.…

Instrumentation and Detectors · Physics 2024-05-16 Qian-Yun Li , Ming-Xuan Li , Ren-Ming-Jie Li , Shin-Ted Lin , Shu-Kui Liu , Chang-Jian Tang , Hao-Yang Xing , Jing-Jun Zhu , Qian Yue , Li-Tao Yang

The radioactive daughters isotope of 222Rn are one of the highest risk contaminants in liquid xenon detectors aiming for a small signal rate. The noble gas is permanently emanated from the detector surfaces and mixed with the xenon target.…

Instrumentation and Detectors · Physics 2018-03-14 Natascha Rupp

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is…

Instrumentation and Detectors · Physics 2021-08-11 Xiangyi Cui , Zhou Wang , Yonglin Ju , Xiuli Wang , Huaxuan Liu , Wenbo Ma , Jianglai Liu , Li Zhao , Xiangdong Ji , Shuaijie Li , Rui Yan , Haidong Sha , Peiyao Huang

Radioactive radon atoms originating from the long-lived primordial $^{238}\mathrm{U}$ and $^{232}\mathrm{Th}$ decay chains are constantly emanated from the surfaces of most materials. The radon atoms and their radioactive daughter isotopes…

Instrumentation and Detectors · Physics 2024-01-30 D. Wiebe , S. Lindemann , M. Schumann

Low-background liquid xenon detectors are utilized in the investigation of rare events, including dark matter and neutrinoless double beta decay. For their calibration, gaseous $^{220}$Rn can be used. After being introduced into the xenon,…

Instrumentation and Detectors · Physics 2023-11-15 Florian Jörg , Shengchao Li , Jochen Schreiner , Hardy Simgen , Rafael F. Lang

The LZ dark matter detector, like many other rare-event searches, will suffer from backgrounds due to the radioactive decay of radon daughters. In order to achieve its science goals, the concentration of radon within the xenon should not…

Instrumentation and Detectors · Physics 2018-01-17 E. H. Miller , J. Busenitz , T. K. Edberg , C. Ghag , C. Hall , R. Leonard , K. Lesko , X. Liu , Yue Meng , A. Piepke , R. W. Schnee

To precisely measure radon concentrations in purified air supplied to the Super-Kamiokande detector as a buffer gas, we have developed a highly sensitive radon detector with an intrinsic background as low as 0.33$\pm$0.07 mBq/m$^{3}$. In…

Instrumentation and Detectors · Physics 2017-04-25 Y. Nakano , H. Sekiya , S. Tasaka , Y. Takeuchi , R. A. Wendell , M. Matsubara , M. Nakahata

In order to solve the continuous large cooling power supply problem (20 kW) for the radon-removal cryogenic distillation system, which operates at high liquid ffow rate of 856 kg/h (5 LPM) for the dark matter detector PandaX-xT of the…

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have…

Instrumentation and Detectors · Physics 2023-01-27 E. Aprile , K. Abe , F. Agostini , S. Ahmed Maouloud , M. Alfonsi , L. Althueser , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , L. Baudis , A. L. Baxter , L. Bellagamba , R. Biondi , A. Bismark , A. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , B. Cimmino , M. Clark , A. P. Colijn , J. Conrad , J. J. Cuenca-García , J. P. Cussonneau , V. D'Andrea , M. P. Decowski , P. Di Gangi , S. Di Pede , A. Di Giovanni , R. Di Stefano , S. Diglio , A. Elykov , S. Farrell , A. D. Ferella , H. Fischer , W. Fulgione , P. Gaemers , R. Gaior , M. Galloway , F. Gao , R. Glade-Beucke , L. Grandi , J. Grigat , A. Higuera , C. Hils , K. Hiraide , L. Hoetzsch , J. Howlett , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , N. Kato , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , M. Messina , K. Miuchi , K. Mizukoshi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , K. Ni , U. Oberlack , J. Palacio , R. Peres , J. Pienaar , M. Pierre , V. Pizzella , G. Plante , J. Qi , J. Qin , D. Ramírez García , S. Reichard , A. Rocchetti , N. Rupp , L. Sanchez , J. M. F. dos Santos , G. Sartorelli , J. Schreiner , D. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , E. Shockley , M. Silva , H. Simgen , A. Takeda , P. -L. Tan , A. Terliuk , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , Y. Wei , C. Weinheimer , M. Weiss , D. Wenz , J. Westermann , C. Wittweg , T. Wolf , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , Y. Zhang , M. Zhong , T. Zhu , J. P. Zopounidis , M. Laubenstein , S. Nisi

The noble elements, argon and xenon, are frequently employed as the target and event detector for weakly interacting particles such as neutrinos and Dark Matter. For such rare processes, background radiation must be carefully minimized.…

Radon is one of the most important sources of background in rare event search experiments, such as those searching for Dark Matter and neutrinos, due to its unavoidable production from natural uranium. In low-background experiments, radon…

Instrumentation and Detectors · Physics 2026-04-29 P. Adhikari , M. G. Boulay , R. Crampton , D. Gallacher , M. Perry

Long-lived radon daughters are a critical background source in experiments searching for low-energy rare events. Originating from radon in ambient air, radioactive polonium, bismuth and lead isotopes plate-out on materials that are later…

Instrumentation and Detectors · Physics 2021-05-05 S. Bruenner , D. Cichon , G. Eurin , P. Herrero Gómez , F. Jörg , T. Marrodán Undagoitia , H. Simgen , N. Rupp

Radon and its progenies are significant sources of background in rare event detection experiments, including dark matter searches like the PandaX-4T experiment and other rare decay studies such as neutrinoless double beta decay (NLDBD). In…

Instrumentation and Detectors · Physics 2025-07-02 Yuan Wu , Lin Si , Zhicheng Qian , Youhui Yun , Yue Meng , Jianglai Liu , Zhixing Gao , Hao Wang , Liangyu Wu , Yuanzi Liang

This article describes a radon emanation measurement technique using liquid scintillator counting. A model for radon loading and transport is described, along with its calibration. Detector background and blank have been studied and…

Instrumentation and Detectors · Physics 2025-01-30 A. B. M. R. Sazzad , P. Acharya , P. Back , J. Busenitz , D. Chernyak , Y. Meng , A. Piepke , C. A. Rhyne , R. Tsang

The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be…

Instrumentation and Detectors · Physics 2017-05-09 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. Le Calloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , I. Cristescu