Related papers: Recent Cross Section Work From NOvA
The NOvA project is a long-baseline neutrino experiment. It utilizes the NuMI neutrino beam at Fermilab and consists of two functionally-identical liquid scintillator filled detectors. The detectors are placed 14 milliradians off-axis from…
NOvA is a long-baseline neutrino oscillation experiment that measures oscillations in charged-current $\nu_{\mu} \rightarrow \nu_{\mu}$ (disappearance) and $\nu_{\mu} \rightarrow \nu_{e}$ (appearance) channels, and their antineutrino…
The NOvA long-baseline neutrino experiment uses a pair of large, segmented, liquid-scintillator calorimeters to study neutrino oscillations, using GeV-scale neutrinos from the Fermilab NuMI beam. These detectors are also sensitive to the…
NuMI Off-axis $\nu_e$ Appearance (NOvA) experiment is an ongoing long baseline neutrino oscillation experiment. The primary channels of interest are the $\nu_e$, $\bar{\nu}_e$ appearance, $\nu_\mu$, $\bar{\nu}_\mu$ disappearance channels…
The NOvA experiment's most recent search for eV-scale sterile neutrinos under a 3+1 model simultaneously analyses muon neutrino and neutral current datasets from the NuMI beam at its Near ($\sim$\qty{1}{km} baseline) and Far (\qty{810}{km}…
We report a search for neutrino oscillations to sterile neutrinos under a model with three active and one sterile neutrinos (3+1 model). This analysis uses the NOvA detectors exposed to the NuMI beam, running in neutrino mode. The data…
NOvA is a long-baseline neutrino oscillation experiment with two functionally identical liquid scintillator tracking detectors, i.e. the Near Detector (ND) and the Far Detector (FD). One of NOvA's physics goal is to measure neutrino…
NOvA is a long-baseline neutrino oscillation experiment. It is optimized to measure $\nu_e$ appearance and $\nu_{\mu}$ disappearance at the Far Detector in the $\nu_{\mu}$ beam produced by the NuMI facility at Fermilab. NOvA uses a…
The majority of neutrino oscillation experiments have obtained evidence for neutrino oscillations that are compatible with the three-flavor model. Explaining anomalous results from short-baseline experiments, such as LSND and MiniBooNE, in…
The physics goals of NOvA are the constraints of neutrino oscillation parameters such as the octant of $\theta_{23}$, $\delta_{\rm{CP}}$, and the neutrino mass hierarchy via a joint fit to $\nu_{\mu}$ and $\nu_{e}$ oscillation spectrum. We…
NOvA is a long-baseline neutrino oscillation experiment that detects neutrino particles from the NuMI beam at Fermilab. Before data from this experiment can be used in analyses, raw hits in the detector must be matched to their source…
This Letter reports results from the first long-baseline search for sterile antineutrinos mixing in an accelerator-based antineutrino-dominated beam. The rate of neutral-current interactions in the two NOvA detectors, at distances of 1 km…
Powerful new multi-kiloton liquid scintillator neutrino detectors, including NOvA and LENA, will come on-line within the next decade. When these are coupled with a modest-power decay-at-rest (DAR) neutrino source at short-baseline, these…
MINERvA is a dedicated neutrino cross-section experiment planned for the near detector hall of the NuMI neutrino beam at Fermilab. I summarize the detector design and physics capabilities of the experiment.
The NOvA long-baseline neutrino experiment consists of two highly active, finely segmented, liquid scintillator detectors located 14.6 mrad off Fermilab's NuMI beam axis, with a Near Detector located at Fermilab, and a Far Detector located…
The two-detector design of the NOvA neutrino oscillation experiment, in which two functionally identical detectors are exposed to an intense neutrino beam, aids in canceling leading order effects of cross-section uncertainties. However,…
The NOvA experiment has made a $4.4\sigma$-significant observation of $\bar\nu_{e}$ appearance in a 2 GeV $\bar\nu_{\mu}$ beam at a distance of 810 km. Using $12.33\times10^{20}$ protons on target delivered to the Fermilab NuMI neutrino…
This is an updated version of the NOvA proposal. The detector is a 30 kiloton tracking calorimeter, 15.7 m by 15.7 m by 132 m long, with alternating horizontal and vertical rectangular cells of liquid scintillator contained in PVC extrusion…
We report results from the first search for sterile neutrinos mixing with active neutrinos through a reduction in the rate of neutral-current interactions over a baseline of 810\,km between the NOvA detectors. Analyzing a 14-kton detector…
We report results from the first search for $\nu_\mu\to\nu_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far…