English
Related papers

Related papers: Differentiation method for localization of Compton…

200 papers

A novel data-processing method was developed to facilitate scintillation detector characterization. Combined with fan-beam calibration, this method can be used to quickly and conveniently calibrate gamma-ray detectors for SPECT, PET,…

Instrumentation and Detectors · Physics 2021-06-24 Xin Li , Li Tao , Craig S. Levin , Lars R. Furenlid

Gamma sources are routinely used to calibrate the energy scale and resolution of liquid scintillator detectors. However, non-scintillating material surrounding the source introduces energy losses, which may bias the determination of the…

Instrumentation and Detectors · Physics 2021-09-01 Feiyang Zhang , Rui Li , Jiaqi Hui , Jianglai Liu , Yue Meng , Yuanyuan Zhang

Scintillation detectors with excellent timing resolution enable more precise localization of radiation sources in positron emission tomography, leading to substantial improvements in diagnostic capability for diseases such as cancer and…

Instrumentation and Detectors · Physics 2026-05-28 Yuya Onishi , Ryosuke Ota , Fumio Hashimoto , Kibo Ote , Go Akamatsu , Hideaki Tashima , Taiga Yamaya

Compton scattering is a well-established technique that can provide detailed information about electronic states in solids. Making use of the principle of tomography, it is possible to determine the Fermi surface from sets of…

Materials Science · Physics 2022-11-10 J. Otsuki , K. Yoshimi , Y. Nakanishi-Ohno , M. Sekania , L. Chioncel , M. Mizumaki

The recent development of scintillation crystals combined with $\gamma$-rays sources opens the way to an imaging concept based on Compton scattering, namely Compton scattering tomography (CST). The associated inverse problem rises many…

Numerical Analysis · Mathematics 2023-02-22 Janek Gödeke , Gaël Rigaud

We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…

Instrumentation and Detectors · Physics 2022-01-27 Ángela Saá Hernández , Diego González-Díaz , Pablo Villanueva , Carlos Azevedo , Marcos Seoane

Organic scintillators are widely used for fast neutron detection and spectroscopy. Several effects complicate the interpretation of results from detectors based upon these materials. First, fast neutrons will often leave a detector before…

Instrumentation and Detectors · Physics 2009-10-29 N. S. Bowden , P. Marleau , J. T. Steele , S. Mrowka , G. Aigeldinger , W. Mengesha

This study presents a novel algorithm based on machine learning (ML) for the precise segmentation and measurement of detonation cells from soot foil images, addressing the limitations of manual and primitive edge detection methods prevalent…

Machine Learning · Computer Science 2024-09-12 Vansh Sharma , Michael Ullman , Venkat Raman

This study shows an implementation of neutron-gamma pulse shape discrimination (PSD) using a two-dimensional convolutional neural network. The inputs to the network are snapshots of the unprocessed, digitized signals from a BC501A detector.…

Instrumentation and Detectors · Physics 2023-06-19 Annesha Karmakar , Anikesh Pal , G. Anil Kumar , Bhavika , V. Anand , Mohit Tyagi

KEDR detector has the tagging system (TS) to study the gamma-gamma processes. To determine the two-photon invariant mass, the energies of the scattered at small angles electrons and positrons are measured by the magnetic spectrometer…

Instrumentation and Detectors · Physics 2014-08-28 V. V. Kaminskiy , N. Yu. Muchnoi , V. N. Zhilich

One contribution to the time resolution of a scintillation detector is the signal time spread due to path length variations of the detected photons from a point source. In an experimental study a rectangular scintillator was excited by…

Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$…

Photons preferentially Compton scatter perpendicular to the plane of polarisation. This property can be exploited to design instruments to measure the linear polarisation of hard X-rays ($\sim$10 - 100 keV). Photons may undergo two…

Instrumentation and Detectors · Physics 2023-01-25 Ettore Del Monte , Sergio Fabiani , Mark Pearce

Simulation studies and spectroscopic measurements are presented regarding the development of a pixel multilayer CdTe detector under development in the context of the COCAE project. The instrument will be used for the localization and…

Instrumentation and Detectors · Physics 2010-11-16 K. Karafasoulis , K. Zachariadou , S. Seferlis , I. Kaissas , C. Lambropoulos , D. Loukas , C. Potiriadis

A kinetic equation for Compton scattering is given that differs from the Kompaneets equation in several significant ways. By using an inverse differential operator this equation allows treatment of problems for which the radiation field…

Astrophysics · Physics 2009-11-07 George B. Rybicki

Many modern digital analyzers offer the ability to record raw pulses from ionizing radiation detectors. We use this opportunity to investigate the effectiveness of Charge Comparison Method in Pulse Shape Discrimination of neutron and gamma…

Detection of $\gamma$-ray polarization in Positron Emission Tomography (PET) is as yet an unexploited feature that could be used as an additional handle to improve signal-to-background ratio in this imaging modality. The $\gamma$…

Instrumentation and Detectors · Physics 2022-08-17 Siddharth Parashari , Mihael Makek , Tomislav Bokulić , Damir Bosnar , Ana Marija Kožuljević , Zdenka Kuncic , Petar Žugec

A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $\gamma$ rays under high-counting rate has been constructed and…

Collision detection plays an important role in simulation, control, and learning for robotic systems. However, no existing method is differentiable with respect to the configurations of the objects, greatly limiting the sort of algorithms…

Robotics · Computer Science 2022-07-04 Kevin Tracy , Taylor A. Howell , Zachary Manchester

Detectors with continuous scintillator and matrix of photomultipliers attached are widely used in modern particle physics, and various medical tomographs. There are two common ways to calculate the coordinates of the scintillation flash via…

Instrumentation and Detectors · Physics 2024-09-20 Khamitov Timur , Vovchenko Ivan