Related papers: Magnetic resonance with squeezed microwaves
In optical detection setups to measure the deflection of micro-cantilevers, part of the sensing light is absorbed, heating the mechanical probe. We present experimental evidences of a frequency shift of the resonant modes of a cantilever…
The measurement of micron-sized mechanical resonators by electrical techniques is difficult, because of the combination of a high frequency and a small mechanical displacement which together suppress the electromechanical coupling. The only…
The use of superconducting micro-resonators in combination with quantum-limited Josephson parametric amplifiers has in recent years lead to more than four orders of magnitude improvement in the sensitivity of pulsed Electron Spin Resonance…
We analyze squeezing of the nanoresonator state produced by periodic measurement of position by a quantum point contact or a single-electron transistor. The mechanism of squeezing is the stroboscopic quantum nondemolition measurement…
Electromagnetic filtering is essential for the coherent control, operation and readout of superconducting quantum circuits at milliKelvin temperatures. The suppression of spurious modes around transition frequencies of a few GHz is well…
We study the use of squeezed probe light and evasion of measurement back-action to enhance the sensitivity and measurement bandwidth of an optically-pumped magnetometer (OPM) at sensitivity-optimal atom number density. By experimental…
Quantum fluctuations impose fundamental limits on measurement and space-time probing. Although using optimised probe fields can allow to push sensitivity in a position measurement beyond the "standard quantum limit", quantum fluctuations of…
Optically-active spin qubits have emerged as powerful quantum sensors capable of nanoscale magnetometry, yet conventional coherent sensing approaches are ultimately limited by the coherence time of the sensor, typically precluding detection…
Low-frequency magnetic fields carry vital information for neuroscience, navigation, and Earth science. However, they are generally weak, making it challenging to measure them with compact, room-temperature magnetometers. To overcome this…
The ultimate precision limit in estimating the Larmor frequency of $N$ unentangled rotating spins is well established, and is highly important for magnetometers, gyroscopes and many other sensors. However this limit assumes perfect, single…
Electron spin resonance (ESR) spectroscopy is the method of choice for characterizing paramagnetic impurities, with applications ranging from chemistry to quantum computing, but it gives access only to ensemble-averaged quantities due to…
Quantum sensors, qubits sensitive to external fields, have become powerful detectors for various small acoustic and electromagnetic fields. A major key to their success have been dynamical decoupling protocols which enhance sensitivity to…
We observed squeezed vacuum light at 795 nm in 87Rb vapor via resonant polarization self-rotation, and report noise sidebands suppression of ~1 dB below shot noise level spanning from acoustic (30 kHz) to MHz frequencies. This is the first…
Nonlinear optical microscopy techniques have emerged as a set of successful tools for biological imaging. Stimulated emission microscopy belongs to a small subset of pump-probe techniques which can image non-fluorescent samples without…
We present a single-quadrature feedback scheme able to overcome the conventional 3 dB limit on parametric squeezing. The method is experimentally demonstrated in a micromechanical system based on a cantilever with a magnetic tip. The…
We demonstrate detection of a weak alternate-current magnetic field by application of the spin echo technique to F = 2 Bose-Einstein condensates. A magnetic field sensitivity of 12 pT/Hz^1/2 is attained with the atom number of 5*10^3 at…
In a recent letter [Auzinsh {\it{et. al.}} (physics/0403097)] we have analyzed the noise properties of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a…
An ensemble of negatively charged nitrogen-vacancy centers in diamond can act as a precise quantum sensor even under ambient conditions. In particular, to optimize thier sensitivity, it is crucial to increase the number of spins sampled and…
Nitrogen-vacancy (NV) magnetometry is a new technique for imaging spin waves in magnetic materials. It detects spin waves by their microwave magnetic stray fields, which decay evanescently on the scale of the spin-wavelength. Here, we use…
We study imaging with an array of sensors that probes a medium with single frequency electromagnetic waves and records the scattered electric field. The medium is known and homogenous except for some small and penetrable inclusions. The…