Related papers: Design of a High-Performance High-Pass Generalized…
Existing sub-/super-synchronous (SSO) suppression methods for the direct-drive permanent magnet synchronous generators (D-PMSG) integrated power systems are mainly achieved by external devices or sub-synchronous resonance damping controller…
Differing from synchronous generators, there are lack of physical laws governing the synchronization dynamics of voltage-source converters (VSCs). The widely used phase-locked loop (PLL) plays a critical role in maintaining the synchronism…
This paper proposes modified Second-Order Generalized Integrators (mSOGIs) for a fast estimation of all harmonic components of arbitrarily distorted single-phase signals such as voltages or currents in power systems. The estimation is based…
Design and implementation of an optimal and robust single-loop voltage controller is proposed for single-phase grid forming voltage source inverter (VSI). The objective of the proposed controller is to have good reference tracking and…
In a phase-locked loop (PLL) synchronized inverter, due to the strong nonlinear coupling between the PLL's parame-ters and the operation power angle, the equivalent damping coefficient will quickly deteriorate while the power angle is close…
This paper presents a novel strategy for the synchronization of grid-following Voltage Source Converters (VSCs) in power systems with low rotational inertia. The proposed synchronization unit is based on emulating the physical properties of…
We consider a grid-connected voltage source converter (VSC) and address the problem of estimating the grid angle and frequency, information that is essential for an appropriate operation of the converter. We design phase-locked loop (PLL)…
Small-signal instability of grid-connected power converters may arise when the converters use a phase-locked loop (PLL) to synchronize with a weak grid. Commonly, this stability problem (referred as PLL-synchronization stability in this…
In the last decades, the applications of power inverter increased rapidly. As a result, in spite of rectifier, an inverter with a high-power electronic oscillator has capability to convert direct current (DC) into alternating current (AC)…
Synchronous reference frame phase-looked loop (SRF-PLL) techniques are widely used for interfacing and control applications in the power systems and energy conversion at large. Since a PLL system synchronizes its output with an exogenous…
This paper presents an extensive framework focused on the control design, along with stability and performance analysis, of Grid-Following Inverters (GFL). It aims to ensure their effective operation under both stiff and weak grid…
The Hybrid Integral Gain Systems (HIGS) has recently gained a lot of attention in the control of precision motion systems. HIGS is a nonlinear low pass filter with a 52 degree phase advantage over its linear counterpart. This property…
The photovoltaic microinverter based two-switch DC-DC flyback converters has been investigated. The microinverter is characterized by the high performance and simple design. The effect of CL and LCL low pass filter on Total Harmonics…
This article proposes the design of H-infinity-based robust current controller for single-phase grid-feeding voltage source inverter with an LCL filter. The main objective of the proposed controller is to have good reference tracking,…
In comparison to the conventional complementary pull-up and pull-down logic structure, the pass transistor logic (PTL) family reduces the number of transistors required to perform logic functions, thereby reducing both area and power…
Fluctuations in phase angle and frequency under large disturbances can lead to loss of synchronism (LOS) in grid-following (GFL) converters. The power angle and frequency of synchronous generators (SGs) correspond to rotor position and…
In this work, a non-linear controller designed using non-linear transformation linearization and feedback is proposed for an inverter connected to a weak grid through a single-stage inductive filter. The proposed strategy is…
Synchronization instability of grid-tied converters during grid faults is a serious concern. For phase-locked loop (PLL) synchronized converters, synchronization stability during grid faults requires that PLL can resynchronize with the…
The phase-locked loop (PLL) used in the doubly fed induction generator (DFIG) can cause frequency coupling phenomena, which will give negative resistance characteristics ofthe DFIG at low frequency, resulting in stability issues under weak…
This paper introduces a conversion matrix method for linear periodically time-variant (LPTV) digital phase-locked loop (DPLL) phase noise modeling that offers precise and computationally efficient results to enable rapid design iteration…