Related papers: Angular resolution of stacked resistive plate cham…
Time Projection Chambers (TPCs) with charge readout via micro pattern gaseous detectors can provide detailed measurements of charge density distributions. We here report on measurements of alpha particle tracks, using a TPC where the drift…
We develop a model predictive control (MPC) policy for station keeping on a Near-Rectilinear Halo Orbit (NRHO). The proposed policy achieves full-state tracking of a reference NRHO via a multiple-maneuver control horizon, each spaced one…
This work has been carried out to simulate a Resistive Plate Chamber and corroborate it with experimental measurements in order to develop a numerical tool for studying the performance of the device for any gas mixture. This will allow us…
Current and next-generation particle tracking detectors will incorporate precision timing capabilities with resolutions approaching tens of picoseconds. Using Technology Computer-Aided Design (TCAD) simulations of Low-Gain Avalanche Diode…
The CYGNO project has the goal to use a gaseous TPC with optical readout to detect dark matter and solar neutrinos with low energy threshold and directionality. The CYGNO demonstrator will consist of 1 m 3 volume filled with He:CF 4 gas…
Multi-gap Resistive Plate Chamber(MRPC) is a widely used timing detector with a typical time resolution of about 60 ps. This makes MRPC an optimal choice for the time of flight(ToF) system in many large physics experiments. The prior work…
Resistive Plate Chambers (RPCs) have traditionally operated with high Global Warming Potential (GWP) gas mixtures, adding to the environmental footprint of large-scale physics experiments. In response, efforts are underway to explore…
We report on the development of an GRPCs (Glass Resistive Plate chambers) Semi- Digital hadron calorimeter for the future International Linear Collider (ILC).Two types of GRPCs (small and 1m2) were tested in PS beam at CERN. Detector…
After the KamLAND results, the remaining important targets in neutrino experiments are to measure still unknown 3 basic parameters; absolute neutrino mass scale, CP violation phase $\delta_{CP}$ and last mixing angle $\theta_{13}$. The…
Primary challenges for current and future precision neutrino experiments using liquid argon time projection chambers (LArTPCs) include understanding detector effects and quantifying the associated systematic uncertainties. This paper…
As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the…
The measurement of the neutrino mixing angle $\theta_{13}$ opens a gateway for the next generation experiments to measure the neutrino mass hierarchy and the leptonic CP-violating phase. Future reactor experiments will focus on mass…
In this work we explore readout architectures for the simultaneous high-resolution timing and bidimensional tracking of charged particles with Resistive Plate Chambers (TOF-tracker) and for the accurate detection of gamma rays for PET…
The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were…
Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreater$~90\%) and time resolution ($\sim$~1-2~ns). Generally,…
A vectorial analysis of magnetic resonance spectrometers, based on traveling wave resonators and including the reference arm and the automatic control of frequency, has been developed. The proposed model, valid also for stationary wave…
Liquid Argon Time Projection Chamber (LArTPC) technology is commonly utilized in neutrino detector designs. It enables detailed reconstruction of neutrino events with high spatial precision and low energy threshold. Its field response (FR)…
The IceCube-Gen2 facility will extend the energy range of IceCube to ultra-high energies. The key component to detect neutrinos with energies above 10 PeV is a large array of in-ice radio detectors. In previous work, direction…
Directional methods have been considered to provide a solid proof for the direct detection of the dark matter. Gaseous time-projection-chambers (TPCs) are the most mature devices for directional dark matter searches although there still…
The Solenoidal Tracker At RHIC (STAR) uses the Time Projection Chamber (TPC) to perform tracking and particle identification. In order to improve the corrections (such as space charge) and monitor non-static distortions of the TPC,…