English
Related papers

Related papers: LBCS: the LOFAR Long-Baseline Calibrator Survey

200 papers

Historically, the blazar population has been poorly understood at low frequencies because survey sensitivity and angular resolution limitations have made it difficult to identify megahertz counterparts. We used the LOFAR Two-Metre Sky…

This paper describes a 561 nm laser heterodyne interferometer that provides time-resolved measurements of line-integrated plasma electron density within the range of 10^15-10^18 cm^(-2). Such plasmas are produced by railguns on the Plasma…

Plasma Physics · Physics 2015-06-03 Elizabeth C. Merritt , Alan G. Lynn , Mark A. Gilmore , Scott C. Hsu

We present the final 6'' resolution data release of the ELAIS-N1 field from the LOw-Frequency ARray (LOFAR) Two-metre Sky Survey Deep Fields project (LoTSS Deep). The 144MHz images are the most sensitive achieved to date at this frequency…

Coming high-cadence wide-field optical telescopes will image hundreds of thousands of sources per minute. Besides inspecting the near real-time data streams for transient and variability events, the accumulated data archive is a wealthy…

Instrumentation and Methods for Astrophysics · Physics 2018-03-20 Bart Scheers , Steven Bloemen , Hannes Mühleisen , Pim Schellart , Arjen van Elteren , Martin Kersten , Paul J. Groot

The maximum baseline, and therefore resolution, of optical astronomical interferometers is limited by attenuation and phase noise within the optical path between the apertures and beam combiner, as well as the practical challenges of…

The calibration and traceability of high resolution frequency modulated continuous wave (FMCW) ladar sources is a requirement for their use in length and volume metrology. We report the calibration of a FMCW ladar length measurement system…

Optics · Physics 2015-03-03 Ana Baselga Mateo , Zeb W. Barber

We have conducted a deep survey (with a central rms of $55\mu\textrm{Jy}$) with the LOw Frequency ARray (LOFAR) at 120-168 MHz of the Bo\"otes field, with an angular resolution of $3.98^{''}\times6.45^{''}$, and obtained a sample of 10091…

We present the first wide area (19 deg$^2$), deep ($\approx120-150$ {\mu}Jy beam$^{-1}$), high resolution ($5.6 \times 7.4$ arcsec) LOFAR High Band Antenna image of the Bo\"otes field made at 130-169 MHz. This image is at least an order of…

The polarization properties of radio sources at very low frequencies (<200 MHz) have not been widely measured, but the new generation of low-frequency radio telescopes, including the Low Frequency Array (LOFAR: a Square Kilometre Array Low…

Aims. We aim to study the far-infrared radio correlation (FIRC) at 150 MHz in the local Universe (at a median redshift z~0:05) and improve the use of the rest-frame 150-MHz luminosity, L150, as a star-formation rate (SFR) tracer, which is…

Compact Steep Spectrum, Gigahertz Peaked Spectrum and High Frequency Peak (CSS, GPS, HFP) sources are considered to be young radio sources but the details of their duty cycle are not well understood. In some cases they are thought to…

Astrophysics of Galaxies · Physics 2016-12-07 M. Brienza , R. Morganti , A. Shulevski , L. Godfrey , N. Vilchez

In this paper, we investigate the relationship between 150MHz luminosity and star formation rate (the SFR-L150 relation) using 150MHz measurements for a near-infrared selected sample of 118,517 $z<1$ galaxies. New radio survey data offer…

We present the first wide area (2.5 x 2.5 deg^2) LOFAR High Band Antenna image at a resolution of 1.2'' x 2'' with a median noise of approximately 80 microJy per beam. It was made from an 8-hour International LOFAR Telescope (ILT)…

We have carried out full imaging simulation studies to explore the impact of frequency standards in millimeter and sub-millimeter Very Long Baseline Interferometry (VLBI), focusing on the coherence time and sensitivity. In particular, we…

Instrumentation and Methods for Astrophysics · Physics 2015-06-11 M. Rioja , R. Dodson , Y. Asaki , J. Hartnett , S. Tingay

I present first results of LOFAR observations with international baselines. An important cornerstone was the detection of the first long-baseline fringes. Their analysis turns out to be extremely useful to investigate and solve a number of…

Instrumentation and Methods for Astrophysics · Physics 2010-08-27 Olaf Wucknitz

LOFAR is the LOw Frequency Radio interferometer ARray located at mid-latitude ($52^{\circ} 53'N$). Here, we present results on ionospheric structures derived from 29 LOFAR nighttime observations during the winters of 2012/2013 and…

We present observations of the XMM Large-Scale Structure (XMM-LSS) field observed with the LOw Frequency ARray (LOFAR) at 120-168 MHz. Centred at a J2000 declination of $-4.5^{\circ}$, this is a challenging field to observe with LOFAR…

The Owens Valley Radio Observatory 40 meter telescope is currently monitoring a sample of about 1700 blazars every three days at 15 GHz, with the main scientific goal of determining the relation between the variability of blazars at radio…

Instrumentation and Methods for Astrophysics · Physics 2015-06-22 Walter Max-Moerbeck

In this data release from the LOFAR Two-metre Sky Survey (LoTSS) we present 120-168MHz images covering 27% of the northern sky. Our coverage is split into two regions centred at approximately 12h45m +44$^\circ$30' and 1h00m +28$^\circ$00'…

Astrophysics of Galaxies · Physics 2022-02-25 T. W. Shimwell , M. J. Hardcastle , C. Tasse , P. N. Best , H. J. A. Röttgering , W. L. Williams , A. Botteon , A. Drabent , A. Mechev , A. Shulevski , R. J. van Weeren , L. Bester , M. Brüggen , G. Brunetti , J. R. Callingham , K. T. Chyży , J. E. Conway , T. J. Dijkema , K. Duncan , F. de Gasperin , C. L. Hale , M. Haverkorn , B. Hugo , N. Jackson , M. Mevius , G. K. Miley , L. K. Morabito , R. Morganti , A. Offringa , J. B. R. Oonk , D. Rafferty , J. Sabater , D. J. B. Smith , D. J. Schwarz , O. Smirnov , S. P. O'Sullivan , H. Vedantham , G. J. White , J. G. Albert , L. Alegre , B. Asabere , D. J. Bacon , A. Bonafede , E. Bonnassieux , M. Brienza , M. Bilicki , M. Bonato , G. Calistro Rivera , R. Cassano , R. Cochrane , J. H. Croston , V. Cuciti , D. Dallacasa , A. Danezi , R. J. Dettmar , G. Di Gennaro , H. W. Edler , T. A. Enßlin , K. L. Emig , T. M. O. Franzen , C. García-Vergara , Y. G. Grange , G. Gürkan , M. Hajduk , G. Heald , V. Heesen , D. N. Hoang , M. Hoeft , C. Horellou , M. Iacobelli , M. Jamrozy , V. Jelić , R. Kondapally , P. Kukreti , M. Kunert-Bajraszewska , M. Magliocchetti , V. Mahatma , K. Małek , S. Mandal , F. Massaro , Z. Meyer-Zhao , B. Mingo , R. I. J. Mostert , D. G. Nair , S. J. Nakoneczny , B. Nikiel-Wroczyński , E. Orrú , U. Pajdosz-Śmierciak , T. Pasini , I. Prandoni , H. E. van Piggelen , K. Rajpurohit , E. Retana-Montenegro , C. J. Riseley , A. Rowlinson , A. Saxena , C. Schrijvers , F. Sweijen , T. M. Siewert , R. Timmerman , M. Vaccari , J. Vink , J. L. West , A. Wołowska , X. Zhang , J. Zheng

Low-cost sensors measurements are noisy, which limits large-scale adaptability in airquality monitoirng. Calibration is generally used to get good estimates of air quality measurements out from LCS. In order to do this, LCS sensors are…

Signal Processing · Electrical Eng. & Systems 2024-02-16 M V Narayana , Kranthi Kumar Rachvarapu , Devendra Jalihal , Shiva Nagendra S M