Related papers: Folding Gravitational-Wave Interferometers
Grazing incidence interferometry has been applied to rough planar and cylindrical surfaces. As suitable beam splitters diffractive optical phase elements are quite common because these allow for the same test sensitivity for all surface…
Optical multilayer coatings of high-reflective mirrors significantly determine the properties of Fabry-Perot resonators. Thermal (Brownian) noise in these coatings produce excess phase noise which can seriously degrade the sensitivity of…
KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted…
Recent researches show that the fluctuations of the dielectric mirrors coating thickness can introduce a substantial part of the future laser gravitational-wave antennae total noise budget. These fluctuations are especially large in the…
We investigate the shot noise limited sensitivity of a four-mirror cavity enhanced Michelson interferometer. The intention of this interferometer topology is the reduction of thermal lensing and the impact of the interferometers contrast…
Reduction of coating thermal noise is a key issue in precise measurements with an optical interferometer. A good example of such a measurement device is a gravitational-wave detector, where each mirror is coated by a few tens of…
It is shown that an optical parametric amplifier inside a cavity can considerably improve the cooling of the micromechanical mirror by radiation pressure. The micromechanical mirror can be cooled from room temperature 300 K to sub-Kelvin…
We investigated the noise of interferometric gravitational wave detectors due to heat energy deposited by cosmic-ray particles. We derived a general formula that describes the response of a mirror against a cosmic-ray passage. We found that…
In modern high precision optical instruments, such as in gravitational wave detectors or frequency references, thermally induced fluctuations in the reflective coatings can be a limiting noise source. This noise, known as coating thermal…
Thermal lensing in resonant optical interferometers such as those used for gravitational wave detection is a concern due to the negative impact on control signals and instrument sensitivity. In this paper we describe a method for monitoring…
We report the results of a recent search for the lowest value of thermal noise that can be achieved in LIGO by changing the shape of mirrors, while fixing the mirror radius and maintaining a low diffractional loss. The result of this…
We describe an optical simulation program that models a complete, coupled-cavity interferometer like those used by the Laser Interferometer Gravitational-Wave Observatory (LIGO) Project. A wide variety of interferometer deformations can be…
We describe an experiment in which we have used a cold damping feedback mechanism to reduce the thermal noise of a mirror around its mechanical resonance frequency. The monitoring of the brownian motion of the mirror allows to apply an…
A new heterodyne detection method is suggested for detecting gravitational waves in a Michelson Interferometer. The method is based on interference between phase changes which are induced by a vibrating mirror with phase changes which are…
Quantum noise limits the sensitivity of precision measurement devices, such as laser interferometer gravitational-wave observatories and axion detectors. In the shot-noise-limited regime, these resonant detectors are subject to a trade-off…
An incoming gravity wave being a stress wave is a surface with intrinsic curvature. When a light beam is parallel transported on this non-Euclidian surface it acquires an excess phase which accumulates with each curcuit. We calculate the…
Present gravitational wave detectors are based on the measurement of linear displacement in stable optical cavities. Here, we instead suggest the measurement of the twist of a chiral mechanical element induced by a gravitational wave. The…
We present an overview of quantum noise in gravitational wave interferometers. Gravitational wave detectors are extensively modified variants of a Michelson interferometer and the quantum noise couplings are strongly influenced by the…
The most sensitive measurements of time and space are made with resonant optical cavities, and these measurements are limited by coating thermal noise. The mechanical and optical performance requirements placed on coating materials,…
We report on thermal noise from the internal friction of dielectric coatings made from alternating layers of Ta2O5 and SiO2 deposited on fused silica substrates. We present calculations of the thermal noise in gravitational wave…