English
Related papers

Related papers: High Precision Current Measurement for Power Conve…

200 papers

In the rapidly advancing landscape of contemporary technology, power electronics assume a pivotal role across diverse applications, ranging from renewable energy systems to electric vehicles and consumer electronics. The efficacy and…

Systems and Control · Electrical Eng. & Systems 2023-10-10 Maryam Bahrami , Zeyad Khashroum

Recent experiments with superconducting qubits are motivated by the goal of fabricating a quantum computer, but at the same time they illuminate the more fundamental aspects of quantum mechanics. In this paper we analyze the physics of…

Mesoscale and Nanoscale Physics · Physics 2013-09-12 G. S. Paraoanu

We use synchrophasor measurements of the complex voltage and current at both ends of multiple transmission lines that connect areas of a power system to monitor the online voltage collapse margin. A new reduction is used to reduce the…

Physics and Society · Physics 2014-12-09 Lina Ramirez , Ian Dobson

Modern society critically depends on the services electric power provides. Power systems rely on a network of power lines and transformers to deliver power from sources of power (generators) to the consumers (loads). However, when power…

Systems and Control · Computer Science 2015-07-21 Karsten Lehmann , Russell Bent , Feng Pan

A multi-detector array has been designed and constructed for the simultaneous measurement of energy- and angular correlations of electron-positron pairs. Experimental results are obtained over a wide angular range for high-energy…

A class of Actively Calibrated Line Mounted Capacitive Voltage Transducers (LMCVT) are introduced as a viable line mountable instrumentation option for deploying large numbers of voltage transducers onto the medium and high voltage systems.…

Instrumentation and Detectors · Physics 2017-01-27 Raffi Sevlian , Ram Rajagopal

Capacitance-voltage (CV) measurements are a widely used technique in silicon detector physics. It gives direct information about the full depletion voltage and the effective doping concentration. However, for highly irradiated sensors, the…

Instrumentation and Detectors · Physics 2023-01-24 Sven Mägdefessel , Riccardo Mori , Niels Sorgenfrei , Ulrich Parzefall

Data-driven methods enable online assessment of error states in magnetic-array-type current sensors, and long-term measurement stability can be enhanced through further self-error correction. However, when the magnetic-array-type current…

Instrumentation and Detectors · Physics 2025-12-09 Xiaohu Liu , Keyu Hou , Kang Ma , Jian Liu , Angang Zheng , Zhengwei Qu , Wei Zhao , Lisha Peng , Songling Huang , Shisong Li

Phasor Measurement Units (PMUs) are measurement devices long used in transmission systems and today even more essential for a proper monitoring of distribution grids. The expected massive penetration of distributed energy resources (DERs)…

Systems and Control · Electrical Eng. & Systems 2020-03-03 Carlo Guarnieri Calo\' Carducci , Gianluca Lipari , Nicola Giaquinto , Ferdinanda Ponci , Antonello Monti

Grid forming control applied to power converters that interface storage or renewable generation to the power grid, has been identified as a potential solution to facilitate a substantial share of converter-based renewable generation in the…

Systems and Control · Electrical Eng. & Systems 2021-06-28 Kanakesh Vatta Kkuni , Guangya Yang

Beam diagnostics and instrumentation are an essential part of any kind of accelerator. There is a large variety of parameters to be measured for observation of particle beams with the precision required to tune, operate, and improve the…

Accelerator Physics · Physics 2020-05-19 Gero Kube

A new system for precise measurements of the field integrals and multipole components of the APS magnetic insertion devices is described. A stretched coil is used to measure magnetic field characteristics. The hardware includes a number of…

High Energy Physics - Experiment · Physics 2007-05-23 Yu. Eidelman , B. Deriy , O. Makarov , I. Vasserman

A pulse-and-hold technique is used to measure the switching of small critical current Josephson junctions. This technique allows one to achieve a good binary detection and therefore measure switching probabilities. The technique overcomes…

Superconductivity · Physics 2017-08-23 J. Walter , S. Corlevi , D. B. Haviland

The effective and reliable operation of particle accelerator machines is strongly related to obtaining and keeping the required ultra-high vacuum level. This paper briefly presents some generic requirements to take in consideration for…

Accelerator Physics · Physics 2020-06-19 G. Bregliozzi

The adjustable capacity of a line-commutated-converter High Voltage Direct Current (LCC-HVDC) connected to a power system, called the LCC-HVDC maximum emergency power capability or HVDC-MC for short, plays an important role in determining…

Systems and Control · Electrical Eng. & Systems 2020-06-23 Long Peng , Junbo Zhao , Yong Tang , Lamine Mili , Zhuoyuan Gu , Zongsheng Zheng

Development of readout electronics for Time Projection Chamber for a Linear Collider is ongoing under stringent requirements on high channel density, lowest possible power consumption and small material budget. In the studied TPC readout…

Instrumentation and Detectors · Physics 2009-02-02 Alexander Kaukher

This article is the second part of a paper series about interference in extremum (i.e., peak or valley) current-mode control, which applies to both fixed and variable switching frequency power converters. Specifically, this part presents…

Systems and Control · Electrical Eng. & Systems 2022-06-22 Xiaofan Cui , Al-Thaddeus Avestruz

We demonstrate precision enhancements in a timekeeping device at constant power and regardless of the operation frequency. Our timekeeping device is a laser-driven coupled-cavity system sustaining limit cycles. We quantify the precision of…

Optics · Physics 2025-09-11 K. J. H. Peters , B. Braeckeveldt , B. Maes , S. R. K. Rodriguez

We describe a high efficiency detector for measuring electron-positron pair transitions in nuclei. The device was built to be insensitive to gamma rays and to accommodate high overall event rates. The design was optimized for total pair…

Instrumentation and Detectors · Physics 2008-07-08 C. Tur , A. H. Wuosmaa , S. M. Austin , K. Starosta , J. Yurkon , A. Estrade , N. Goodman , J. C. Lighthall , G. Lorusso , S. T. Marley , J. Snyder

The variance of an arbitrary pointer observable is considered for the general case that a complex weak value is measured using a complex valued pointer state. For the typical cases where the pointer observable is either its position or…

Quantum Physics · Physics 2015-05-27 A. D. Parks , J. E. Gray