Related papers: Microcalorimeter pulse analysis by means of princi…
The next generation of cosmology space missions will be sensitive to parasitic signals arising from cosmic rays. Using a composite bolometer, we have investigated pulses produced by $\alpha$ particles in order to understand the movement of…
We present a theoretical study of the potential of Principal Component Analysis to analyse magnetic diffuse neutron scattering data on quantum materials. To address this question, we simulate the scattering function…
The spectrum of laser-plasma generated X-rays is very important, it characterizes electron dynamics in plasma and is basic for applications. However, the accuracies and efficiencies of existing methods to diagnose the spectrum of…
Voltage fluctuations are common disturbances in power grids. Initially, it is necessary to selectively identify individual sources of voltage fluctuations to take actions to minimize the effects of voltage fluctuations. Selective…
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi…
For a high source activity experiment, such as HOLMES, non-constant baseline pulses could constitute a great fraction of the data-set. We test the optimal filter matrix technique, proposed to process these pulses, on simulated responses of…
This work proposes a component based model for the raw ultrasound signals acquired by the transducer elements. Based on this approach, before undergoing the standard digital processing chain, every sampled raw signal is first decomposed…
Principal component analysis is a powerful statistical system to investigate the structure and dynamics of the molecular interstellar medium, with particular emphasis on the study of turbulence, as revealed by spectroscopic imaging of…
We present a principal component analysis method which tracks and compensates for short-timescale variability in pulsar profiles, with a goal of improving pulsar timing precision. We couple this with a fast likelihood technique for…
In this paper, we present our approach to systematically measure numerous performance parameters of MCP-PMTs. The experimental setups, the analyses and selected results are discussed. Although the techniques used may be different in other…
Photoelectron spectroscopy is a powerful method that provides insight into the quantum mechanical properties of a wide range of systems. The ionized electron wavefunction carries information on the structure of the bound orbital, the ionic…
Human heartbeat can be measured using several different ways appropriately based on the patient condition which includes contact base such as measured by using instruments and non-contact base such as computer vision assisted techniques.…
Attosecond streaking, as a measurement technique, was originally conceived as a means to characterize attosecond light pulses, which is a good approximation if the relevant transition matrix elements are approximately constant within the…
Principal component analysis is a statistical method, which lowers the number of important variables in a data set. The use of this method for the bursts' spectra and afterglows is discussed in this paper. The analysis indicates that three…
Measuring the spectral phase of a pulse is key for performing wavelength resolved ultrafast measurements in the few femtosecond regime. However, accurate measurements in real experimental conditions can be challenging. We show that the…
We have implemented a new approach for measuring the time-dependent intensity and phase of ultrashort optical pulses. It is based on the interaction between shaped pulses and atoms, leading to coherent transients.
Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC…
We have proposed and developed a method to utilize attosecond pulses in diffraction imaging techniques applied to complex samples. In this study, the effects of the broadband properties of the wavefield owing to attosecond pulses are…
We report in this paper the proofs that the pulse shape analysis can be used in some bolometers to identify the nature of the interacting particle. Indeed, while detailed analyses of the signal time development in purely thermal detectors…
In recent years, Artificial Intelligence techniques have proved to be very successful when applied to problems in physical sciences. Here we apply an unsupervised Machine Learning (ML) algorithm called Principal Component Analysis (PCA) as…