Related papers: Beam Emittance Measurement for PLS-II Linac
Preinjector VEPP-5 electron linac consists of two linear accelerators on energy 300 MeV and 510 MeV and includes 14 accelerating structures [1]. First accelerating structures both linacs have increased average rate of acceleration 25-30…
The emission optics of a Steigerwald type electron gun is re-examined. The virtual and real points of divergence, divergence angles and beam-widths of the electron beams at different telefocusing strength are measured in detail for first…
This paper presents a comprehensive technical overview of the Linac Coherent Light Source II (LCLS-II) photoinjector laser system, its first and foremost component. The LCLS-II photoinjector laser system serves as an upgrade to the original…
This report describes a concept of an EIC cooling system, based on a proven induction linac technology with a dc electron beam. The system would operate in a full energy range of proton beams (100 - 270 GeV) and would provide 50-100 A…
The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…
In this paper we present a new measurement setup, where a transitionedge sensor detector array is used to detect X-rays in particle induced X-ray emission measurements with a 2 MeV proton beam. Transition-edge sensors offer orders of…
The Proton Improvement Plan II (PIPII) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beams for neutrino production. The Linac requires cooling at 80 K, 5 K, and 2 K temperatures, which will…
The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such…
In the described device, the thermal emissivity or absorptivity of the sample is measured by substitution of the radiative heat flow between two parallel surfaces by thermal output of a heater. Fast measurements of the mutual emissivity for…
The solenoid scan is a widely used method for the in-situ measurement of the thermal emittance in a photocathode gun. The popularity of this method is due to its simplicity and convenience since all rf photocathode guns are equipped with an…
As soon as the first particles emerge from an ion source, the source characteristics need to be determined. The total beam intensity, the transverse particle distributions, the beam divergence and emittance as well as the longitudinal…
We report the experimental demonstration of femtosecond electron diffraction using high-brightness MeV electron beams. High-quality, single-shot electron diffraction patterns for both polycrystalline aluminum and single-crystal 1T-TaS2 are…
The Low-Energy Demonstration Accelerator (LEDA) radio-frequency quadrupole (RFQ) is a 100% duty factor (CW) linac that delivers >100 mA of H+ beam at 6.7 MeV. The 8-m-long, 350-MHz RFQ structure accelerates a dc, 75-keV, 110-mA H+ beam from…
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the…
The generation of low-emittance electron beams has received significant interest in recent years. Driven by the requirements of X-ray free electron lasers, the emittance of photocathode injectors has been reduced significantly, with a…
From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained…
The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise…
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the…
We describe the construction and calibration of a multi-channel liquid time projection chamber filled with Tetramethylsilane (TMS). Its charge readout system consists of 8 wires each in the $X$ and $Y$ directions. The chamber is also…
A system for online measurement of the transverse beam emittance was developed. It is named $^{4}$PrOB$\varepsilon$aM (4-Profiler Online Beam Emittance Measurement) and was conceived to measure the emittance in a fast and efficient way…