English
Related papers

Related papers: R&D towards the CMS RPC Phase-2 upgrade

200 papers

The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its…

The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation of the RPC response is a crucial part of the entire CMS…

CMS experiment constructed the fourth Resistive Plate Chamber (RPC) trigger station composed of 144 RPCs to enhance the high momentum muon trigger efficiency at both endcap regions. All new CMS endcap RPC gaps are produced in accordance…

Instrumentation and Detectors · Physics 2015-06-22 Sung Keun Park , Min Ho Kang , Kyong Sei Lee

The High Luminosity LHC phase includes an upgrade to the muon stations for the CMS Experiment. CMS trigger and muon identification performance will be crucial, and it is, therefore, necessary to install new GEM stations to extend acceptance…

Based on the CMS Upgrade R&D Proposal RD10.02, we describe the motivation and main features of the CMS GEM Project for LS2 and propose the addition of a full GE1/12 detector station comprising Gas Electron Multiplier (GEM) chambers to the…

Instrumentation and Detectors · Physics 2012-12-03 D. Abbaneo , M. Abbrescia , P. Aspell , S. Bianco , K. Hoepfner , M. Hohlmann , M. Maggi , G. De Lentdecker , A. Safonov , A. Sharma , M. Tytgat

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions…

Instrumentation and Detectors · Physics 2020-06-09 CMS Muon Group

The CMS muon system has played a key role for many physics results obtained from the LHC Run-1 data. During the Long Shutdown (2013-2014) significant upgrades have been carried out on the muon detectors and on the L1 muon trigger. In…

Instrumentation and Detectors · Physics 2019-08-13 Giovanni Abbiendi

The High-Luminosity LHC (HL-LHC, or Phase 2 LHC) will deliver proton-proton collisions at 5-7.5 times the nominal LHC luminosity, with an expected number of 140-200 pp-interactions per bunch crossing (Pile-up or PU). To maintain the…

Instrumentation and Detectors · Physics 2023-07-19 Piet Verwilligen

We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…

The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC…

Instrumentation and Detectors · Physics 2020-12-15 R. Hadjiiska , A. Samalan , M. Tytgat , N. Zaganidis , G. A. Alves , F. Marujo , F. Torres Da Silva De Araujo , E. M. Da Costa , D. De Jesus Damiao , H. Nogima , A. Santoro , S. Fonseca De Souza , A. Aleksandrov , P. Iaydjiev , M. Rodozov , M. Shopova , G. Sultanov , M. Bonchev , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , C. Bernal , A. Cabrera , J. Fraga , A. Sarkar , S. Elsayed , Y. Assran , M. El Sawy , M. A. Mahmoud , Y. Mohammed , C. Combaret , M. Gouzevitch , G. Grenier , I. Laktineh , L. Mirabito , K. Shchablo , I. Bagaturia , D. Lomidze , I. Lomidze , V. Bhatnagar , R. Gupta , P. Kumari , J. Singh , V. Amoozegar , B. Boghrati , M. Ebraimi , R. Ghasemi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , R. Aly , W. Elmetenawee , N. De Filippis , A. Gelmi , G. Iaselli , S. Leszki , F. Loddo , I. Margjeka , G. Pugliese , D. Ramos , M. Caponero , L. Benussi , S. Bianco , S. Colafranceschi , A. Russo , L. Passamonti , D. Piccolo , D. Pierluigi , G. Saviano , S. Buontempo , A. Di Crescenzo , F. Fienga , G. De Lellis , L. Lista , S. Meola , P. Paolucci , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , B. Francois , T. J. Kim , J. Park , S. Y. Choi , B. Hong , K. S. Lee , J. Goh , H. Lee , J. Eysermans , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , C. A. Mondragon Herrera , D. A. Perez Navarro , G. A. Ayala Sanchez , S. Carrillo , E. Vazquez , A. Radi , A. Ahmad , I. Asghar , H. Hoorani , S. Muhammad , M. A. Shah , I. Crotty

CMS experiment will use Resistive Plate Chambers (RPCs) as dedicated muon trigger detectors. The first 24 RPCs for the barrel muon system of the CMS experiment have been assembled and tested. A brief description of the cosmic muon telescope…

Instrumentation and Detectors · Physics 2010-11-19 Borislav Pavlov

The Phase II upgrade of the ATLAS Muon Spectrometer will involve the installation of approximately 1000 next-generation Resistive Plate Chamber (RPC) singlets. This upgrade aims to enhance detector coverage, increase hit efficiency, and…

Instrumentation and Detectors · Physics 2025-06-23 Aashaq Shah

The CMS muon system is undergoing substantial upgrades to meet the challenges of the High-Luminosity LHC (HL-LHC), including the installation of the new Muon Endcap 0 (ME0) detector. Large-scale production started in 2024. ME0 is a…

Instrumentation and Detectors · Physics 2026-03-05 Anureet Kaur

The innermost station of the present ATLAS forward muon detector needs to be upgraded for the super-LHC. We present a proposal to replace it with a sandwiched detector composed of several layers of small-radius Monitored Drift Tube chambers…

Instrumentation and Detectors · Physics 2012-10-26 Junjie Zhu

Operating the CMS Level-1 trigger under the intense conditions of the High-Luminosity Large Hadron Collider -- with approximately 63~Tb/s of input and a fixed 12.5~$\mu$s latency -- poses a demanding real-time reconstruction challenge. The…

High Energy Physics - Experiment · Physics 2025-09-30 Pelayo Leguina , Santiago Folgueras , Andrea Cardini , Elena Aller

Resistive Plate Chambers are used in the ATLAS experiment for the muon trigger and two coordinate measurements in the central region. In preparation for the coming years of LHC running at higher luminosity, besides the New Small Wheel…

Instrumentation and Detectors · Physics 2020-10-30 Lorenzo Massa

The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large…

Instrumentation and Detectors · Physics 2023-07-19 E. Shumka , A. Samalan , M. Tytgat , M. El Sawy , G. A. Alves , F. Marujo , E. A. Coelho , E. M. Da Costa , H. Nogima , A. Santoro , S. Fonseca De Souza , D. De Jesus Damiao , M. Thiel , K. Mota Amarilo , M. Barroso Ferreira Filho , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , M. Shopova , G. Soultanov , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , H. Kou , Z. -A. Liu , J. Zhao , J. Song , Q. Hou , W. Diao , P. Cao , C. Avila , D. Barbosa , A. Cabrera , A. Florez , J. Fraga , J. Reyes , Y. Assran , M. A. Mahmoud , Y. Mohammed , I. Crotty , I. Laktineh , G. Grenier , M. Gouzevitch , L. Mirabito , K. Shchablo , I. Bagaturia , I. Lomidze , Z. Tsamalaidze , V. Amoozegar , B. Boghrati , M. Ebraimi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , G. Iaselli , G. Pugliese , F. Loddo , N. De Filippis , R. Aly , D. Ramos , W. Elmetenawee , S. Leszki , I. Margjeka , D. Paesani , L. Benussi , S. Bianco , D. Piccolo , S. Meola , S. Buontempo , F. Carnevali , L. Lista , P. Paolucci , F. Fienga , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , E. Asilar , J. Choi , T. J. Kim , S. Y. Choi , B. Hong , K. S. Lee , H. Y. Oh , J. Goh , I. Yu , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , R. L. Fernandez , M. Ramirez-Garcia , E. Vazquez , M. A. Shah , N. Zaganidis , A. Radi , H. Hoorani , S. Muhammad , A. Ahmad , I. Asghar , W. A. Khan , J. Eysermans , F. Torres Da Silva De Araujo

Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future…

Instrumentation and Detectors · Physics 2018-12-12 Aashaq Shah , CMS-Muon Collaboration