English
Related papers

Related papers: Optical fiber read-out for liquid argon scintillat…

200 papers

Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the…

Instrumentation and Detectors · Physics 2015-09-02 W. Creus , Y. Allkofer , C. Amsler , A. D. Ferella , J. Rochet , L. Scotto-Lavina , M. Walter

The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this…

Instrumentation and Methods for Astrophysics · Physics 2025-02-14 Nicolas De Angelis , Franck Cadoux , Coralie Husi , Merlin Kole , Sławomir Mianowski

Xenon-doped liquid argon has been proposed as a good alternative to pure liquid argon in scintillation detectors. In this study, we report on the measurement of the time profile of scintillation light emitted from xenon-doped liquid argon…

Instrumentation and Detectors · Physics 2021-02-23 Cristiano Galbiati , Xinran Li , Jingyu Luo , Daniel R. Marlow , Hanguo Wang , Yi Wang

We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in…

Efficient Wavelength Shifters (WLS) are crucial for Liquid Argon (LAr) dark matter detectors. As they grow larger in volume, the scalability of WLS becomes an important concern. Tetraphenyl butadiene (TPB), the most common WLS in use,…

Instrumentation and Detectors · Physics 2025-04-18 Sarthak Choudhary

The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities.…

Instrumentation and Detectors · Physics 2021-03-24 B. Aimard , L. Aizawa , C. Alt , J. Asaadi , M. Auger , V. Aushev , D. Autiero , A. Balaceanu , G. Balik , L. Balleyguier , E. Bechetoille , D. Belver , A. M. Blebea-Apostu , S. Bolognesi , S. Bordoni , N. Bourgeois , B. Bourguille , J. Bremer , G. Brown , G. Brunetti , L. Brunetti , D. Caiulo , M. Calin , E. Calvo , M. Campanelli , K. Cankocak , C. Cantini , B. Carlus , B. M. Cautisanu , M. Chalifour , A. Chappuis , N. Charitonidis , A. Chatterjee , A. Chiriacescuf , P. Chiu , S. Conforti , P. Cotte , P. Crivelli , C. Cuesta , J. Dawson , I. De Bonis , C. De La Taille , A. Delbart , S. Di Luise , F. Doizon , C. Drancourt , D. Duchesneau , F. Dulucq , F. Duval , S. Emery , A. Ereditato , A. Falcone , K. Fusshoeller , A. Gallego-Ros , V. Galymov , N. Geffroy , A. Gendotti , A. Gherghel-Lascu , I. Gil-Botella , C. Girerd , M. C. Gomoiu , P. Gorodetzky , E. Hamada , R. Hanni , T. Hasegawa , A. Holin , S. Horikawa , M. Ikeno , S. Jiménez , A. Jipa , M. Karolak , Y. Karyotakis , S. Kasai , K. Kasami , T. Kishishita , H. Konari , I. Kreslo , D. Kryn , P. Kunzé , M. Kurokawa , Y. Kuromori , C. Lastoria , I. Lazanu , G. Lehmann-Miotto , M. Leyton , N. Lira , K. Loo , D. Lorca , P. Lutz , T. Lux , J. Maalampi , G. Maire , M. Maki , L. Manenti , R. M. Margineanu , J. Marteau , G. Martin-Chassard , H. Mathez , E. Mazzucato , G. Misitano , D. Mladenov , L. Molina Bueno , T. S. Mosu , W. Mu , S. Murphy , K. Nakayoshi , S. Narita , D. Navas-Nicolás , K. Negishi , M. Nessi , M. Niculescu-Oglinzanu , F. Noto , A. Noury , Y. Onishchuk , C. Palomares , M. Parvu , T. Patzak , Y. Penichot , E. Pennacchio , L. Periale , H. Pessard , F. Pietropaolo , D. Pugnere , B. Radics , D. Redondo , C. Regenfus , A. Remoto , F. Resnati , O. Ristea , A. Rubbia , A. Saftoiu , K. Sakashita , F. Sanchez , C. Santos , A. Scarpelli , C. Schloesser , K. Sendai , F. Sergiampietri , S. Shahsavarani , M. Shoji , J. Sinclair , J. Soto-Oton , D. I. Stanca , D. Stefan , R. Sulej , M. Tanaka , V. Toboaru , A. Tonazzo , W. Tromeur , W. H. Trzaska , T. Uchida , L. Urda , F. Vannucci , G. Vasseur , A. Verdugo , T. Viant , S. Vihonen , S. Vilalte , M. Weber , S. Wu , J. Yu , L. Zambelli , M. Zito

The propagation velocity of scintillation light in liquid argon $v_{g}$ at $\lambda \sim 128$~nm wavelength, has been measured for the first time in a dedicated experimental setup at CERN.\\ The obtained result $\frac{1}{v_{g}} = 7.46 \pm…

Instrumentation and Detectors · Physics 2021-07-30 M. Babicz , S. Bordoni , A. Fava , U. Kose , M. Nessi , F. Pietropaolo , G. L. Raselli , F. Resnati , M. Rossella , P. Sala , F. Stocker , A. Zani

First observation of liquid xenon scintillation due to alpha-particles and gamma-rays with a large area avalanche photodiode immersed in the liquid is reported. An energy resolution of 10% (FWHM) and a coincidence time resolution of less…

Instrumentation and Detectors · Physics 2015-06-26 V. N. Solovov , A. Hitachi , V. Chepel , M. I. Lopes , R. Ferreira Marques , A. J. P. L. Policarpo

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based…

Instrumentation and Detectors · Physics 2022-07-20 D. E. Fields , and R. Gibbons M. Gold , N. McFadden , S. R. Elliott , R. Massarczyk

An 800L liquid xenon scintillation $\gamma$ ray detector is being developed for the MEG experiment which will search for $\mu^+\to\mathrm{e}^+\gamma$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by…

Discrimination between electron and nuclear recoil events in a liquid argon scintillation detector has been demonstrated with simulations by using the differences in the scintillation photon time distribution between these classes of…

Astrophysics · Physics 2007-05-23 M. G. Boulay , A. Hime

A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd…

Instrumentation and Detectors · Physics 2015-11-25 T. Heindl , T. Dandl , M. Hofmann , R. Krücken , L. Oberauer , W. Potzel , J. Wieser , A. Ulrich

Our group from the University of Zurich is performing R&D work towards the design of a large liquid argon detector to detect Weakly Interacting Massive Particles (WIMPs). This project is developed within the DARWIN Collaboration funded by…

Instrumentation and Detectors · Physics 2015-03-19 C. Amsler

Neutrino experiments using liquid argon (LAr) detectors estimate the amount of light produced by different types of particles, but only consider scintillation light, at 128 nm, ignoring Cherenkov light contributions. This research aims to…

High Energy Physics - Phenomenology · Physics 2024-08-05 Hasan R. Rahman

ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to…

A large number of particle detectors employ liquid argon as their target material owing to its high scintillation yield and its ability to drift ionization charge over large distances. Scintillation light from argon is peaked at 128 nm and…

In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts,…

Instrumentation and Detectors · Physics 2015-03-17 A. Stoykov , R. Scheuermann , A. Amato , M. Bartkowiak , J. A. Konter , J. Rodriguez , K. Sedlak

In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the…

The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions,…

Instrumentation and Detectors · Physics 2015-11-25 M. Hofmann , T. Dandl , T. Heindl , A. Neumeier , L. Oberauer , W. Potzel , S. Roth , S. Schönert , J. Wieser , A. Ulrich

We have developed a novel tracking detector utilizing a water-based liquid scintillator (WbLS) for the accurate characterization of neutrino interactions on a water target. In this detector, the WbLS is optically segmented into small cells…

Instrumentation and Detectors · Physics 2025-12-10 Naoto Onda , Yuka Asano , Takashi Iida , Tatsuya Kikawa , Tsuyoshi Nakaya , Atsushi Tokiyasu , Daiki Wakabayashi