English
Related papers

Related papers: Lumped Element Kinetic Inductance Detectors for sp…

200 papers

Lumped-element kinetic inductance detectors(LEKIDs) have recently shown considerable promise as direct absorption mm-wavelength detectors for astronomical applications. One major research thrust within the N\'eel Iram Kids Array (NIKA)…

Instrumentation and Methods for Astrophysics · Physics 2019-08-13 M. Roesch , A. Benoit , A. Bideaud , N. Boudou , M. Calvo , A. Cruciani , S. Doyle , H. G. Leduc , A. Monfardini , L. Swenson , S. Leclercq , P. Mauskopf , K. F. Schuster

This work intends to give the state-of-the-art of our knowledge of the performance of LEKIDs at millimetre wavelengths (from 80 to 180~GHz). We evaluate their optical sensitivity under typical background conditions and their interaction…

Instrumentation and Methods for Astrophysics · Physics 2016-07-13 A. Catalano , A. Benoit , O. Bourrion , M. Calvo , G. Coiffard , A. D'Addabbo , J. Goupy , H. Le Sueur , J. Macìas-Pérez , A. Monfardini

We report the design, fabrication and testing of Lumped Element Kinetic Inductance Detectors (LEKID) showing performance in line with the requirements of the next generation space telescopes operating in the spectral range from 80 to 600…

Instrumentation and Methods for Astrophysics · Physics 2022-10-19 A. Catalano , A. Bideaud , O. Bourrion , M. Calvo , A. Fasano , J. Goupy , F. Levy-Bertrand , J. F. Macìas-Pérez , N. Ponthieu , Q. Y. Tang , A. Monfardini

Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the…

We have developed Lumped Element Kinetic Inductance Detectors (LEKID) sensitive in the frequency band from 80 to 120~GHz. In this work, we take advantage of the so-called proximity effect to reduce the superconducting gap of Aluminium,…

Instrumentation and Methods for Astrophysics · Physics 2015-07-22 A. Catalano , J. Goupy , H. le Sueur , A. Benoit , O. Bourrion , M. Calvo , L. Dumoulin , F. Levy-Bertrand , J. Macìas-Pérez , S. Marnieros , N. Ponthieu , A. Monfardini

The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow directly comparing LEKID performance with other competing technologies (TES, doped silicon)…

Instrumentation and Methods for Astrophysics · Physics 2016-03-23 J. Goupy , A. Adane , A. Benoit , O. Bourrion , M. Calvo , A. Catalano , G. Coiffard , C. Hoarau , S. Leclercq , H. Le Sueur , J. Macias-Perez , A. Monfardini , I. Peck , K. Schuster

We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background (CMB) studies. The LEKIDs are made from a thin aluminum film deposited…

Instrumentation and Methods for Astrophysics · Physics 2015-03-27 H. McCarrick , D. Flanigan , G. Jones , B. R. Johnson , P. Ade , D. Araujo , K. Bradford , R. Cantor , G. Che , P. Day , S. Doyle , H. Leduc , M. Limon , V. Luu , P. Mauskopf , A. Miller , T. Mroczkowski , C. Tucker , J. Zmuidzinas

We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments…

The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band camera operating with three frequency multiplexed kilo-pixels arrays of Lumped…

We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and…

The New IRAM KID Array 2 (NIKA 2) is a dual-band camera operating with three frequency-multiplexed kilopixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK. NIKA 2 is designed to observe the intensity and…

The New IRAM KID Array (NIKA) is a dual-band camera operating with frequency multiplexed arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs) cooled to 100 mK. NIKA is designed to observe the intensity and polarisation of the sky…

We report on the performance of lumped--elements Kinetic Inductance Detector (KID) arrays for mm and sub--mm wavelengths, operated at 0.3K during the stratospheric flight of the OLIMPO payload, at an altitude of 37.8 km. We find that the…

We are developing a Lumped Element Kinetic Inductance Detector (LEKID) array able to operate in the W-band (75-110 GHz) in order to perform ground-based Cosmic Microwave Background (CMB) and mm-wave astronomical observations. The W-band is…

Instrumentation and Methods for Astrophysics · Physics 2016-01-08 A. Paiella , A. Coppolecchia , M. G. Castellano , I. Colantoni , A. Cruciani , A. D'Addabbo , P. de Bernardis , S. Masi , G. Presta

Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. To circumvent this it is imperative to investigate technologies that intrinsically incorporate strong…

The kinetic inductance detector (KID) is a versatile and scalable detector technology with a wide range of applications. These superconducting detectors offer significant advantages: simple and robust fabrication, intrinsic multiplexing…

Instrumentation and Detectors · Physics 2022-03-31 Peter S. Barry , Clarence. C. Chang , Sunil Golwala , Erik Shirokoff

We present recent developments in Kinetic Inductance Detectors (KID) for large arrays of detectors. The main application is ground-based millimeter wave astronomy. We focus in particular, as a case study, on our own experiment: NIKA (N\'eel…

Instrumentation and Methods for Astrophysics · Physics 2012-01-30 Nicolas Boudou , Alain Benoit , Olivier Bourrion , Martino Calvo , François-Xavier Désert , Juan Macias-Perez , Alessandro Monfardini , Markus Roesch

Future space-based far infra-red astronomical observations require background limited detector sensitivities and scalable focal plane array solutions to realise their vast potential in observation speed. In this work, a focal plane array of…

We have developed a passive 350 GHz (850 {\mu}m) video-camera to demonstrate lumped element kinetic inductance detectors (LEKIDs) -- designed originally for far-infrared astronomy -- as an option for general purpose terrestrial terahertz…

This work aims to demonstrate that two arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs), when employed in filled array configuration and separated by an external linear polarizer oriented at 45 degrees, can achieve the…