English
Related papers

Related papers: Single electron multiplication distribution in GEM…

200 papers

Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO$_2$ in 70/30 ratio and conventional NIM electronics. A…

Instrumentation and Detectors · Physics 2018-04-10 S. Roy , S. Rudra , S. Shaw , R. P. Adak , S. Biswas , S. Das , S. K. Ghosh , S. K. Prasad , S. Raha

The gain measurements of several 1 mm-thick, 10$\times$10 cm$^2$ Thick Gaseous Electron Multipliers (ThGEMs), operated in pure argon at 3.3 bar and room temperature are presented. Electrostatic simulations, performed with the COMSOL…

Instrumentation and Detectors · Physics 2025-10-07 G. Eurin , A. Delbart , R. De Oliveira , A. Drozd , P. Granger , M. Karolak , B. Mehl

Gas Electron Multiplier (GEM) is one of the mostly used gaseous detectors in the High Energy Physics (HEP) experiments. GEMs are widely used as tracking devices due to their high-rate handling capability and good position resolution. An…

High Energy Physics - Experiment · Physics 2024-01-23 S. Mandal , S. Chatterjee , A. Sen , S. Gope , S. Dhani , A. C. Hegde , M. Chatterjee , S. Das , S. Biswas

We present results from our recent investigations on detectors comprising cascaded gas electron multipliers (GEM) and cascaded GEMs with micro-hole and strip (MHSP) electrodes. We discuss the factors governing the operation of these fast…

We describe a concept for a NASA SMEX Mission in which Gas Electron Multiplier (GEM) detectors, developed at CERN, are adapted for use in X-ray astronomy. These detectors can be used to obtain moderately large detector area and…

Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting…

Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to…

Instrumentation and Detectors · Physics 2008-11-26 R. Chechik , M. Cortesi , A. Breskin , D. Vartsky , D. Bar , V. Dangendorf

Secondary discharges, which consist of the breakdown of a gap near a GEM foil upon a primary discharge across that GEM, are studied in this work. Their main characteristics are the occurrence a few $10\,\mu \textrm{s}$ after the primary,…

Separate absorption charge multiplication germanium tin on silicon avalanche photodiode offers a viable solution to achieve CMOS compatible, high sensitivity detection technology in SWIR or extended SWIR range, leveraging the excellent…

We present a gated silicon single photon detector based on a commercially available avalanche photodiode. Our detector achieves a photon detection efficiency of 45\pm5% at 808 nm with 2x 10^-6 dark count per ns at -30V of excess bias and…

Instrumentation and Detectors · Physics 2015-06-11 T. Lunghi , E. Pomarico , C. Barreiro , D. Stucki , B. Sanguinetti , H. Zbinden

Discrepancies between the measured and simulated gain in Thick Micropatterned gaseous detectors (MPGD), namely THGEM, have been observed by several groups. In order to simulate the electron avalanches and the gain the community relies on…

Instrumentation and Detectors · Physics 2016-09-21 C. D. R. Azevedo , P. M. Correia , L. F. N. D. Carramate , A. L. M. Silva , J. F. C. A. Veloso

Silicon Photo-Multipliers (SiPMs) are detectors sensitive to single photons that are used to detect scintillation and Cherenkov light in a variety of physics and medical-imaging applications. SiPMs measure single photons by amplifying the…

Instrumentation and Detectors · Physics 2019-10-23 G. Gallina , F. Retiere , P. Giampa , J. Kroeger , P. Margetak , S. Byrne Mamahit , A. De St. Croix , F. Edaltafar , N. Massacret , M. Ward , G. Zhang

Magnetic guiding fields in combination with energy dispersive semiconductor detectors have been employed already more than 50 years ago for in-beam internal conversion electron spectroscopy. Even then it was recognized that efficiency…

Instrumentation and Detectors · Physics 2015-03-25 H. Backe

We have developed a novel technique for the measurement of the avalanche fluctuation of gaseous detectors using a UV laser. The technique is simple and requires a short data-taking time of about ten minutes. Furthermore, it is applicable…

We present characterization results of two silicon photomultipliers; the Hamamatsu LVR-6050-CN and the Ketek PM3325 WB. With our measurements of the bias dependence of the breakdown probability we are able to draw conclusions about the…

Instrumentation and Detectors · Physics 2018-12-18 Adam Nepomuk Otte , Thanh Nguyen , Joel Stansbury

Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of GEM foils, however with the…

Instrumentation and Detectors · Physics 2016-01-15 M. Posik , B. Surrow

Multi-channel wire gas electron multipliers (MWGEM) with gaps between the electrodes of 1 and 3mm were investigated. The chamber of the MWGEM was filled with pure commercial neon gas at pressure of 0.4 or 1.0 bar and irradiated by…

Instrumentation and Detectors · Physics 2010-05-11 B. M. Ovchinnikov , V. V. Parusov , Yu. B. Ovchinnikov

An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the…

Instrumentation and Detectors · Physics 2017-04-25 T. Hildén , E. Brücken , J. Heino , M. Kalliokoski , A. Karadzhinova , R. Lauhakangas , E. Tuominen , R. Turpeinen

The design of multi-channel gas electron multiplier (MGEM) with metallic electrodes is proposed, produced and tested. The electrodes of MGEM are produced from the brass plates with thickness of 1 mm, round openings of 1 mm in diameter and…

Instrumentation and Detectors · Physics 2010-06-17 B. M. Ovchinnikov , V. V. Parusov , Yu. B. Ovchinnikov

We have developed a new design of a GEM-like detector with single-layer electrodes made of a resistive kapton. This detector can operate at gains close to 10E5 even in pure Ar and Ne and if transited to discharges at higher gains they, due…

Plasma Physics · Physics 2008-11-26 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi
‹ Prev 1 4 5 6 7 8 10 Next ›