Related papers: Amplitude dependence of image quality in atomicall…
Among the various machine learning methods solving partial differential equations, the Random Feature Method (RFM) stands out due to its accuracy and efficiency. In this paper, we demonstrate that the approximation error of RFM exhibits…
In ultrasound (US) imaging, various types of adaptive beamforming techniques have been investigated to improve the resolution and contrast-to-noise ratio of the delay and sum (DAS) beamformers. Unfortunately, the performance of these…
Stereo Imaging technology integration into medical diagnostics and surgeries brings a great revolution in the field of medical sciences. Now, surgeons and physicians have better insight into the anatomy of patients' organs. Like other…
Emerging sonography techniques often imply increasing in the number of transducer elements involved in the imaging process. Consequently, larger amounts of data must be acquired and processed by the beamformer. The significant growth in the…
The signal to noise ratio (SNR) is one of the important measures for reducing the noise.A technique that uses a linear prediction error filter (LPEF) and an adaptive digital filter (ADF) to achieve noise reduction in a speech and image…
Resonant frequency modulation spectroscopy has been previously used as a highly-sensitive method for measuring the output of cold atom interferometers. Using a detailed model that accounts for optical saturation, laser intensities and…
In this paper we show that the sensitivity of absorption imaging of ultracold atoms can be significantly improved by imaging in a standing-wave configuration. We present simulations of single-atom absorption imaging both for a…
In recent years several methods to overcome diffraction limit in the far field microscopy have been demonstrated. Still the problem of superresolution is reliably solved only for fluorescent microscopy, giving a resolution of up to 20-30nm.…
Photoacoustic imaging is a new imaging technology in recent years, which combines the advantages of high resolution and rich contrast of optical imaging with the advantages of high penetration depth of acoustic imaging. Photoacoustic…
Noise is an important issue for radiographic and tomographic imaging techniques. It becomes particularly critical in applications where additional constraints force a strong reduction of the Signal-to-Noise Ratio (SNR) per image. These…
The angular resolution measure (ARM) is widely used in Compton camera analyses to characterize angular uncertainty and to define event selection criteria. However, the ARM distribution is fundamentally different from the point spread…
One of the common algorithms used to reconstruct photoacoustic (PA) images is the non-adaptive Delay-and-Sum (DAS) beamformer. However, the quality of the reconstructed PA images obtained by DAS is not satisfying due to its high level of…
The objective of image super-resolution is to reconstruct a high-resolution (HR) image with the prior knowledge from one or several low-resolution (LR) images. However, in the real world, due to the limited complementary information, the…
Scanning acoustic microscopy (SAM) has been employed since microscopic images are widely used for biomedical or materials research. Acoustic imaging is an important and well-established method used in nondestructive testing (NDT),…
We use a $^{87}\text{Rb}$ atomic vapor, suitable for an optically-pumped magnetometer (OPM) in Earth-field conditions, to study the noise properties of three strategies for generating pulsed optical pumping. We compare a frequency-modulated…
The increasing popularity of spatial audio in applications such as teleconferencing, entertainment, and virtual reality has led to the recent developments of binaural reproduction methods. However, only a few of these methods are…
Sound speed heterogeneities can create aberrations in B-mode ultrasound images by inducing tissue-dependent delays and diffractive effects that conventional beamforming does not incorporate. By using the Fourier split-step method to…
Emerging sonography techniques often require increasing the number of transducer elements involved in the imaging process. Consequently, larger amounts of data must be acquired and processed. The significant growth in the amounts of data…
Since space-domain information can be utilized, microphone array beamforming is often used to enhance the quality of the speech by suppressing directional disturbance. However, with the increasing number of microphone, the complexity would…
Optical tracking was used to characterize acoustic radiation force (ARF) induced displacements in a tissue-mimicking phantom. Amplitude modulated (AM) 3.3 MHz ultrasound was used to induce ARF in the phantom which was embedded with 10…