English
Related papers

Related papers: Discrimination of nuclear and electronic recoil ev…

200 papers

Experiments built to search for neutrinoless double beta-decay are limited in their sensitivity not only by the exposure but also by the amount of background encountered. Radioactive isotopes in the surrounding of the detectors which emit…

Nuclear Experiment · Physics 2008-11-26 I. Abt , A. Caldwell , K. Kröninger , J. Liu , X. Liu , B. Majorovits

Germanium is the detector material of choice in many rare-event searches looking for low-energy nuclear recoils induced by dark matter particles or neutrinos. We perform a systematic exploration of its quenching factor for sub-keV nuclear…

Nuclear Experiment · Physics 2021-06-30 J. I. Collar , A. R. L. Kavner , C. M. Lewis

We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment.…

Directional detection of nuclear recoils is broadly desirable in nuclear and particle physics. At low recoil energies, this capability may be used to confirm the cosmological origin of a dark matter signal, to penetrate the so-called…

Instrumentation and Detectors · Physics 2021-10-13 Majd Ghrear , Sven E. Vahsen , Cosmin Deaconu

The gamma-ray tracking technique is one of the highly efficient detection method in experimental nuclear structure physics. On the basis of this method, two gamma-ray tracking arrays, AGATA in Europe and GRETA in the USA, are currently…

Instrumentation and Detectors · Physics 2013-01-17 Serkan Akkoyun , Nihat Yildiz

In the framework of the ``ULTIMA'' project, we use ultra cold superfluid 3He bolometers for the direct detection of single particle events, aimed for a future use as a dark matter detector. One parameter of the pulse shape observed after…

Instrumentation and Detectors · Physics 2009-11-13 J. Elbs , Yu. M. Bunkov , E. Collin , H. Godfrin , O. Suvorova

The scintillation mechanism in NaI:Tl crystals produces different pulse shapes that are dependent on the incoming particle type. The time distribution of scintillation light from nuclear recoil events decays faster than for electron recoil…

Experiments searching for rare processes like neutrinoless double beta decay heavily rely on the identification of background events to reduce their background level and increase their sensitivity. We present a novel machine learning based…

Instrumentation and Detectors · Physics 2019-06-04 P. Holl , L. Hauertmann , B. Majorovits , O. Schulz , M. Schuster , A. J. Zsigmond

The discrepancies in claims of experimental evidence in the search for weakly interacting massive particle (WIMP) dark matter necessitate a model for ionization efficiency (the quenching factor) at energies below 10 keV. We have carefully…

Instrumentation and Methods for Astrophysics · Physics 2015-06-04 D. Barker , D. -M. Mei

We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass…

Instrumentation and Detectors · Physics 2009-10-31 P. Meunier , M. Bravin , M. Bruckmayer , S. Giordano , M. Loidl , O. Meier , F. Proebst , W. Seidel , M. Sisti , L. Stodolsky , S. Uchaikin , L. Zerle

Nuclear recoil measurements with high-purity Germanium detectors are very promising to directly detect dark matter candidates. The main background sources in such experiments are natural radioactivity and microphonic noise. Digital pulse…

High Energy Physics - Experiment · Physics 2009-10-31 L. Baudis , J. Hellmig , H. V. Klapdor-Kleingrothaus , Y. Ramachers , J. W. Hammer , A. Mayer

We report the first measurement of discrimination between low-energy helium recoils and electron recoils in liquid xenon. This result is relevant to proposed low-mass dark matter searches which seek to dissolve light target nuclei in the…

High Energy Physics - Experiment · Physics 2024-03-25 S. J. Haselschwardt , R. Gibbons , H. Chen , S. Kravitz , A. Manalaysay , Q. Xia , P. Sorensen , W. H. Lippincott

Four categories of events have been identified in the EDELWEISS-I dark matter experiment using germanium cryogenic detectors measuring simultaneously charge and heat signals. These categories of events are interpreted as electron and…

The lattice dynamics following particle interactions remain not fully understood, and effects from nuclear-recoil interactions in conventional solid-state detectors - such as defect formation - can hinder accurate event-energy…

High Energy Physics - Experiment · Physics 2025-09-23 A J Biffl , Gerardo D Gonzalez , A N Villano , N Mirabolfathi

DD and DT reaction rates may be compared to determine plasma temperatures in the 10--200 eV range. Distinguishing neutrons from these two reactions is difficult when yields are low or unpredictable. Time of flight methods fail if the source…

Instrumentation and Detectors · Physics 2014-06-11 J. I. Katz

To reduce background in experiments looking for rare events, such as the GERDA double beta decay experiment, it is necessary to employ active background-suppression techniques. One of such techniques is the pulse shape analysis of signals…

Nuclear Experiment · Physics 2008-12-10 Dušan Budjáš , Marik Barnabé Heider , Oleg Chkvorets , Stefan Schönert , Nikita Khanbekov

Due to screening effects, nuclear reactions in astrophysical plasmas may behave differently than in the laboratory. The possibility to determine the magnitude of these screening effects in colliding laser-generated plasmas is investigated…

Plasma Physics · Physics 2017-03-29 Yuanbin Wu , Adriana Pálffy

The sensitivity of experiments searching for neutrinoless double beta-decay of germanium was so far limited by the background induced by external gamma-radiation. Segmented germanium detectors can be used to identify photons and thus reduce…

Nuclear Experiment · Physics 2008-11-26 I. Abt , A. Caldwell , K. Kröninger , J. Liu , X. Liu , B. Majorovits

We report an absolute energy response function to electronic and nuclear recoils for germanium and liquid xenon detectors. As a result, we show that the detection energy threshold of nuclear recoils for a dual-phase xenon detector can be a…

Instrumentation and Detectors · Physics 2017-03-29 D. -M. Mei , W. -Z. Wei , L. Wang

Using a new technique to directly detect current induced on a nearby electrode, we measure plasma oscillations in ultracold plasmas, which are influenced by the inhomogeneous and time-varying density and changing neutrality. Electronic…

Plasma Physics · Physics 2012-02-10 K. A. Twedt , S. L. Rolston
‹ Prev 1 2 3 10 Next ›