English
Related papers

Related papers: Performance Studies of Bulk Micromegas of Differen…

200 papers

The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

Gas Electron Multiplier (GEM) detectors, typically featuring a standard pitch size of 140 $\mu$m and an inner hole diameter of 50 $\mu$m, are extensively utilized in high-energy physics experiments for tracking, triggering, and timing…

High Energy Physics - Experiment · Physics 2025-05-07 Rajiv Gupta , Gauri Devi , Sunidhi Saxena , Arpit Singh , Ajay Kumar

A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at…

Instrumentation and Detectors · Physics 2015-06-03 F. J. Iguaz , E. Ferrer-Ribas , A. Giganon , I. Giomataris

Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas…

We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space…

Instrumentation and Detectors · Physics 2016-09-21 S. Aiola , R. J. Ehlers , S. Gu , J. W. Harris , R. Majka , J. D. Mulligan , M. Oliver , J. Schambach , N. Smirnov

Working gas components significantly impact the performance of gaseous detectors. A fast-timing Micromegas detector with two-stage amplification is prone to notable deterioration of uniformity when scaled up. This paper presents a…

Instrumentation and Detectors · Physics 2024-11-08 Yue Meng , Xu Wang , Jianbei Liu , Ming Shao , Zhiyong Zhang , Yi Zhou

Micromegas detector is considered to be a promising candidate for a large variety of high-rate experiments. Micromegas of various geometries have already been established as appropriate for these experiments for their performances in terms…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Supratik Mukhopadhyay , Nayana Majumdar , Sudeb Bhattacharya

The gain measurements of several 1 mm-thick, 10$\times$10 cm$^2$ Thick Gaseous Electron Multipliers (ThGEMs), operated in pure argon at 3.3 bar and room temperature are presented. Electrostatic simulations, performed with the COMSOL…

Instrumentation and Detectors · Physics 2025-10-07 G. Eurin , A. Delbart , R. De Oliveira , A. Drozd , P. Granger , M. Karolak , B. Mehl

The latest Micromesh Gas Amplification Structures (Micromegas) are achieving outstanding energy resolution for low energy photons, with values as low as 11% FWHM for the 5.9 keV line of $^{55}$Fe in argon/isobutane mixtures at atmospheric…

Instrumentation and Detectors · Physics 2015-05-13 T. Dafni , E. Ferrer-Ribas , I. Giomataris , Ph. Gorodetzky , F. Iguaz , I. G. Irastorza , P. Salin , A. Tomas

The operation of gas detectors is often limited by secondary effects, originating from avalanche-induced photons and ions. Ion backflow is one of the effects limiting the operation of a gas detector at high flux, by giving rise to space…

A new Micromegas manufacturing technique, based on kapton etching technology, has been recently developed, improving the uniformity and stability of this kind of readouts. Excellent energy resolutions have been obtained, reaching 11% FWHM…

In this study we investigate the stability limits of Micromegas detectors upon irradiation with alpha particles. The results are obtained with meshes with different optical transparency and geometry of wires. The measurements are performed…

Instrumentation and Detectors · Physics 2023-06-13 P. Gasik , T. Waldmann , L. Fabbietti , T. Klemenz , L. Lautner , B. Ulukutlu

We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of…

Instrumentation and Detectors · Physics 2022-08-03 F. J. Iguaz , T. Dafni , C. Canellas , J. F. Castel , S. Cebrián , J. G. Garza , I. G. Irastorza , G. Luzón , H. Mirallas , E. Ruiz Chóliz

Background: we develop the concept of a Micromegas (MICRO-MEsh GAseous Structure) readout plane with an additional GEM (Gas Electron Multiplier) preamplification stage placed a few mm above it, to increase the maximum effective gain of the…

New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…

The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…

Micromegas is one of the detector technologies (along with the small Thin Gap Chambers) that has been chosen for precision tracking and triggering purposes of the ATLAS muon forward detectors in the view of LHC luminosity increase. To…

Instrumentation and Detectors · Physics 2015-06-17 Georgios Iakovidis

Micromegas is a type of micro-pattern gaseous detector currently under R&D for applications in rare event search experiments. Here we report the performance of a Micromegas structure constructed with a micromesh thermo-bonded to a readout…

Instrumentation and Detectors · Physics 2014-05-13 Yuehuan Wei , Liang Guan , Zhiyong Zhang , Qing Lin , Xiaolian Wang , Kaixuan Ni , Tianchi Zhao

A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…

To solve the discharge of the standard Bulk Micromegas and GEM detector, the GEM-Micromegas detector was developed in Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a…

Instrumentation and Detectors · Physics 2015-06-15 YuLian Zhang , HuiRong Qi , BiTao Hu , ShengNan Fan , Bo Wang , Mei Liu , Jian Zhang , RongGuang Liu , GuangCai Chang , Peng Liu , Qun Ouyang , YuanBo Chen , FuTing Yi
‹ Prev 1 2 3 10 Next ›