English
Related papers

Related papers: SoLid: Search for Oscillation with a 6Li Detector …

200 papers

The SNO+ experiment is a large multi-purpose neutrino detector, currently filled with liquid scintillator. For the first time in a single experiment, SNO+ is able to measure the neutrino oscillation parameters $\theta_{12}$ and $\Delta…

High Energy Physics - Experiment · Physics 2024-03-29 Daniel Cookman

In the last decades, the results from a number of short-baseline neutrino experiments and the reanalysis of previous reactor experiments with updated antineutrino fluxes suggest some incompatibility with the standard three-neutrino model. A…

High Energy Physics - Experiment · Physics 2015-05-01 Debra Dewhurst

The electron antineutrino spectrum in the Stereo reactor experiment (ILL Grenoble) is measured via the inverse beta decay signals in an organic liquid scintillator. The six target cells of the Stereo detector are filled with about 1800…

Instrumentation and Detectors · Physics 2019-01-30 Christian Buck , Benjamin Gramlich , Manfred Lindner , Christian Roca , Stefan Schoppmann

The NOMAD experiment has been designed to search for neutrino-tau appearance in the CERN wide-band neutrino beam . The detector is now completed and has been further improved. All subdetectors are working well. The experiment, where the…

High Energy Physics - Phenomenology · Physics 2010-12-23 Marco Laveder

There is accumulating evidence for a difference between neutrino and antineutrino oscillations at the $\sim 1$ eV$^2$ scale. The MiniBooNE experiment observes an unexplained excess of electron-like events at low energies in neutrino mode,…

Borexino is a unique detector able to perform measurement of solar neutrinos fluxes in the energy region around 1 MeV or below due to its low level of radioactive background. It was constructed at the LNGS underground laboratory with a goal…

The results of LSND and MiniBooNE, along with the recent papers on a possible reactor neutrino flux anomaly give tantalizing hints of new physics. Models beyond the neutrino-SM have been developed to explain these results and involve one or…

In this paper I give an overview of the status of neutrino oscillation experiments performed using nuclear reactors as sources of neutrinos. I review the present generation of experiments (Chooz and Palo Verde) with baselines of about 1 km…

High Energy Physics - Experiment · Physics 2009-10-31 Giorgio Gratta

The measurement of the flux of beryllium neutrinos with the accuracy of about 10% and CNO neutrinos with the accuracy 30% will enable to find the flux of pp-neutrinos in the source with the accuracy better than 1% using the luminosity…

High Energy Physics - Phenomenology · Physics 2009-11-10 A. Kopylov , I. Orekhov , V. Petukhov , A. Solomatin , M. Arnoldov

Some evidence for sterile neutrinos has been found in short baseline observations where the measured neutrino flux did not agree with expectations. Systematic uncertainties from the expected values has limited the sensitivity of this…

High Energy Physics - Experiment · Physics 2015-08-26 John LoSecco

There has been an increasing interest in the monitoring of nuclear fuel for power reactors by detecting the anti-neutrinos produced during operation. Small liquid scintillator detectors have already demonstrated sensitivity to operational…

Instrumentation and Detectors · Physics 2007-05-23 R. W. McKeown , D. E. Reyna

RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in…

The T2K experiment is a long-baseline accelerator neutrino experiment using a near detector complex ND280 and a far detector, Super-Kamiokande. Neutrino interactions are detected by Cherenkov light in Super-Kamiokande in order to measure…

High Energy Physics - Experiment · Physics 2019-08-14 L. Haegel

The sterile neutrino interpretation of the LSND and MiniBooNE neutrino anomalies is currently being tested at three Liquid Argon detectors: MicroBooNE, SBND, and ICARUS. It has been argued that a degeneracy between $\nu_\mu \to \nu_e$ and…

High Energy Physics - Phenomenology · Physics 2025-03-19 Ohana Benevides Rodrigues , Matheus Hostert , Kevin J. Kelly , Bryce Littlejohn , Pedro A. N. Machado , Ibrahim Safa , Tao Zhou

We explore the sensitivity to new physics of the recently proposed vIOLETA experiment: a 10 kg Skipper Charged Coupled Device detector deployed 12 meters away from a commercial nuclear reactor core. We investigate two broad classes of…

High Energy Physics - Phenomenology · Physics 2022-03-09 G. Fernandez-Moroni , R. Harnik , P. A. N. Machado , I. Martinez-Soler , Y. F. Perez-Gonzalez , D. Rodrigues , S. Rosauro-Alcaraz

In this study, simulation-based design and optimization studies of a gadolinium loaded segmented plastic scintillator detector are presented for monitoring applications of nuclear reactors in Turkey using antineutrinos. For the first time…

Instrumentation and Detectors · Physics 2019-12-25 Sertac Ozturk

We present the first measurement of nuclear recoils from solar $^8$B neutrinos via coherent elastic neutrino-nucleus scattering with the XENONnT dark matter experiment. The central detector of XENONnT is a low-background, two-phase time…

High Energy Physics - Experiment · Physics 2026-02-10 E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , D. Antón Martin , F. Arneodo , L. Baudis , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , K. Boese , A. Brown , G. Bruno , R. Budnik , C. Cai , C. Capelli , J. M. R. Cardoso , A. P. Cimental Chávez , A. P. Colijn , J. Conrad , J. J. Cuenca-García , V. D'Andrea , L. C. Daniel Garcia , M. P. Decowski , A. Deisting , C. Di Donato , P. Di Gangi , S. Diglio , K. Eitel , A. Elykov , A. D. Ferella , C. Ferrari , H. Fischer , T. Flehmke , M. Flierman , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , M. Galloway , F. Gao , S. Ghosh , R. Giacomobono , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guida , P. Gyorgy , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , Y. Kaminaga , M. Kara , P. Kavrigin , S. Kazama , M. Kobayashi , D. Koke , A. Kopec , F. Kuger , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , Y. -T. Lin , S. Lindemann , M. Lindner , K. Liu , M. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , T. Luce , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , E. Masson , S. Mastroianni , A. Melchiorre , J. Merz , M. Messina , A. Michael , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , Y. Pan , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , L. Principe , J. Qi , J. Qin , D. Ramírez García , M. Rajado , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , J. Shi , M. Silva , H. Simgen , A. Takeda , P. -L. Tan , D. Thers , F. Toschi , G. Trinchero , C. D. Tunnell , F. Tönnies , K. Valerius , S. Vecchi , S. Vetter , F. I. Villazon Solar , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong

Antineutrinos from a nuclear reactor comprise an unshieldable signal which carries information about the core. A gadolinium-doped, water-based Cherenkov detector could detect reactor antineutrinos for mid- to far-field remote reactor…

Instrumentation and Detectors · Physics 2023-02-28 Liz Kneale , Steve T Wilson , Tara Appleyard , James Armitage , Niamh Holland , Matthew Malek

It is considered the detection of neutrinos moving from the opposite directions. The states of the particle of the detector interacting with the neutrinos are connected with the P-transformation. Hence only a half of neutrinos gives…

General Physics · Physics 2007-05-23 D. L. Khokhlov

The Sudbury Neutrino Observatory (SNO) is a water imaging Cherenkov detector. Utilising a 1 kilotonne ultra-pure D2O target, it is the first experiment to have equal sensitivity to all flavours of active neutrinos. This allows a solar-model…

Nuclear Experiment · Physics 2019-08-14 Gordon A. McGregor