We consider the problem of minimizing costs in the generation unit commitment problem, a cornerstone in electric power system operations, while enforcing an N-k-e reliability criterion. This reliability criterion is a generalization of the…
As renewable wind energy penetration rates continue to increase, one of the major challenges facing grid operators is the question of how to control transmission grids in a reliable and a cost-efficient manner. The stochastic nature of wind…
As renewable wind energy penetration rates continue to increase, one of the major challenges facing grid operators is the question of how to control transmission grids in a reliable and a cost-efficient manner. The stochastic nature of wind…
We consider the problem of designing (or augmenting) an electric power system at a minimum cost such that it satisfies the N-k-e survivability criterion. This survivability criterion is a generalization of the well-known N-k criterion, and…
The problem of maintaining power system stability and performance after the failure of any single line in a power system (an "N-1 contingency") is investigated. Due to the large number of possible N-1 contingencies for a power network, it…
Keeping the balance between supply and demand is a fundamental task in power system operational planning practices. This task becomes particularly challenging due to the deepening penetration of renewable energy resources, which induces a…
Unit maintenance and unit commitment are two critical and interrelated aspects of electric power system operation, both of which face the challenge of coordinating efforts to enhance reliability and economic performance. This challenge…
In this paper, we study unit commitment (UC) problems considering the uncertainty of load and wind power generation. UC problem is formulated as a chance-constrained two-stage stochastic programming problem where the chance constraint is…
A power system unit commitment (UC) problem considering uncertainties of renewable energy sources is investigated in this paper, through a distributionally robust optimization approach. We assume that the first and second order moments of…
Optimization models have been broadly used within side the energy industry as useful decision-making systems for scheduling and dispatching electric powered energy resources; this is applied in a system called unit commitment (UC). Unit…
Modern network-constrained unit commitment (NCUC) bears a heavy computational burden due to the ever-growing model scale. This situation becomes more challenging when detailed operational characteristics, complicated constraints, and…
In the face of extreme events, e.g., hurricanes, the transmission systems, especially the transmission lines, are affected across time and space. To mitigate these impacts on the day-ahead market from a probabilistic perspective, a…
This paper examines the use of contingency analysis for a nuclear power plant to determine its potential benefits for the nuclear industry. Various N-1 contingencies were analyzed for a model of an existing nuclear plant, primarily…
Due to the established energy production methods contribution to the climate crisis, renewable energy is to replace a substantial part of coal or nuclear plants to prevent greenhouse gases or toxic waste entering the atmosphere. This…
Security-constrained unit commitment (SCUC) model is used for power system day-ahead scheduling. However, current SCUC model uses a static network to deliver power and meet demand optimally. A dynamic network can provide a lower optimal…
Power systems Unit Commitment (UC) problem determines the generator commitment schedule and dispatch decisions for power networks based on forecasted electricity demand. However, with the increasing penetration of renewables and stochastic…
Traditionally, power system operations use a static network to deliver power and meet demand optimally. Network topology reconfiguration through transmission switching (TS) has gained significant interest recently to reduce the operational…
Current contingency reserve criteria ignore the likelihood of individual contingencies and, thus, their impact on system reliability and risk. This paper develops an iterative approach, inspired by the current security-constrained unit…
The short-term operation of a power system is usually planned by solving a day-ahead unit commitment problem. Due to historical reasons, the commitment of the power generating units is decided over a time horizon typically consisting of the…
Day-ahead unit commitment (UC) is a fundamental task for power system operators, where generator statuses and power dispatch are determined based on the forecasted nodal net demands. The uncertainty inherent in renewables and load…