English
Related papers

Related papers: Reducing current noise in cryogenic experiments by…

200 papers

Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts…

Instrumentation and Detectors · Physics 2016-08-11 Rachpon Kalra , Arne Laucht , Juan P. Dehollain , Daniel Bar , Solomon Freer , Stephanie Simmons , Juha T. Muhonen , Andrea Morello

Pulse-tube based dilution refrigerators are massively employed in low temperature physics. They allow to reduce the running costs and to be operated with unprecedented easiness. However, the main drawback of this technology is the…

Instrumentation and Detectors · Physics 2018-09-05 R. Maisonobe , J. Billard , M. De Jesus , A. Juillard , D. Misiak , E. Olivieri , S. Sayah , L. Vagneron

We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss…

We studied noise properties of microwave signals transmitted through the cryogenic resonator. The experiments were performed with the 11.342 GHz sapphire loaded cavity resonator cooled to 6.2 K. Based on the measured transmission…

Instrumentation and Detectors · Physics 2021-02-23 Eugene Ivanov , Michael Tobar

We experimentally demonstrated a new method for reducing the vibration of the cold stage of a cryocooler. Comparing the RMS amplitude with the case of no phase shift of the driving gas pressure between the two pairs, the longitudinal…

Instrumentation and Detectors · Physics 2007-05-23 T. Suzuki , T. Tomaru , T. Haruyama , N. Sato , A. Yamamoto , T. Shintomi , Y. Ikushima , R. Li

This manuscript reports a set of acceleration measurements in the frequency range from 0 to 50 kHz performed at the mixing chamber plate (2 axes) and the top flange (3 axes) of a cryogen-free dilution refrigerator. Various configurations of…

Applied Physics · Physics 2019-02-20 D. Schmoranzer , A. Luck , E. Collin , A. Fefferman

A shift of paradigm to obtain (sub-)Kelvin environment is currently on-going with the democratization of cryogen-free cryocoolers, boosted by their easy-to-use and continuous operation without the need of liquid helium whose cost and…

Other Condensed Matter · Physics 2025-10-06 Mathieu Taupin , Kamel Dougdag , Djamel Ziane , Francois Couedo

A cryogen-free cryostat cooled by a closed cycle cryocooler is compact, can provide uninterrupted long-term operation (up to ten thousand hours) and is suited to temperatures from 3 K to 300 K. Its intrinsic temperature oscillation,…

We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres…

Instrumentation and Detectors · Physics 2025-08-28 D. P. Kapasi , T. G. McRae , J. Eichholz , P. A. Altin , D. E. McClelland , B. J. J. Slagmolen

We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and…

Instrumentation and Detectors · Physics 2022-11-10 S. M. Fleischer , M. P. Ross , K. Venkateswara , C. A. Hagedorn , E. A. Shaw , E. Swanson , B. R. Heckel , J. H. Gundlach

A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…

Applied Physics · Physics 2020-08-26 Joris Vincent van Heijningen

Vibrations in cryocoolers are a recurrent concern to the end user. They appear in different parts of the acoustic spectrum depending on the refrigerator type, Gifford McMahon or pulse-tube, and with a variable coupling strength to the…

Instrumentation and Detectors · Physics 2019-04-05 Anne Louchet-Chauvet , Rose Ahlefeldt , Thierry Chanelière

A cryogen-free cryostat cooled using a 4 K commercial GM or pulse tube cryocooler (PTC) displays temperature oscillations caused by the intrinsic working principle of the regenerative cryocooler. To dampen such oscillations usually requires…

We report on our design of a scanning gate microscope housed in a cryogen-free dilution refrigerator with a base temperature of 15 mK. The recent increase in efficiency of pulse tube cryocoolers has made cryogen-free systems popular in…

Instrumentation and Detectors · Physics 2014-09-09 Matthew Pelliccione , Adam Sciambi , John Bartel , Andrew Keller , David Goldhaber-Gordon

We show that fast technical fluctuations of microwave signals can be strongly suppressed by cryogenic resonators. The experiments were carried out with sapphire resonators cooled to approximately 6 K at frequencies around 11 GHz. Each…

Applied Physics · Physics 2024-03-28 Eugene N. Ivanov , Michael E. Tobar

A Cryogenic Sapphire Oscillator has been implemented at 11.2 GHz using a low-vibration design pulse-tube cryocooler. Compared with a state-of-the-art liquid helium cooled CSO in the same laboratory, the square root Allan variance of their…

Instrumentation and Detectors · Physics 2016-11-17 John G. Hartnett , Nitin R. Nand , Chao Wang , Jean-Michel Le Floch

We report an accurate measurement of the phase noise of a thermally limited electronic oscillator at 300 K. By thermally limited we mean that the white signal-to-noise ratio of the oscillator is at or near the level generated by the thermal…

Instrumentation and Detectors · Physics 2017-01-13 Archita Hati , Craig W. Nelson , David Pappas , David A. Howe

Pulse tube refrigerators are becoming more common, because they are cost efficient and demand less handling than conventional (wet) refrigerators. However, a downside of a pulse tube system is the vibration level at the cold-head, which is…

Instrumentation and Detectors · Physics 2014-04-16 A. M. J. den Haan , G. H. C. J. Wijts , F. Galli , O. Usenko , G. J. C. van Baarle , D. J. van der Zalm , T. H. Oosterkamp

Cryogenic quantum sensing techniques are developing alongside the ever-increasing requirements for noiseless experimental environments. For instance, several groups have isolated internal system vibrations from cold heads in closed-cycle…

Instrumentation and Detectors · Physics 2019-08-20 Jonah Cerbin , Ilya Sochnikov