Related papers: Model for the Cherenkov light emission of TeO$_{2}…
An active discrimination of the dominant $\alpha$-background is the prerequisite for future neutrinoless double-beta decay experiments based on TeO$_{2}$ bolometers. We investigate such $\alpha$-particle rejection in cryogenic TeO$_{2}$…
TeO$_2$ crystals have proven to be superb bolometers for the search of neutrinoless double beta decay in many respects. However, if used alone, they do not exhibit any feature that allows to discriminate an alpha energy deposit from a…
Bolometric detectors are excellent devices for the investigation of neutrinoless double-beta decay (0$\nu\beta\beta$). The observation of such decay would demonstrate the violation of lepton number, and at the same time it would necessarily…
A new generation of cryogenic light detectors exploiting Neganov-Luke effect to enhance the thermal signal has been used to detect the Cherenkov light emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism a high…
Bolometers have proven to be good instruments to search for rare processes because of their excellent energy resolution and their extremely low intrinsic background. In this kind of detectors, the capability of discriminating alpha…
Active background reduction in high resolution calorimeters is a promising approach to achieve ultimate sensitivity in neutrinoless double beta decay experiments. We propose Cerenkov emission from beta rays in bolometric crystals as a…
CUORE, an array of 988 TeO$_2$ bolometers, is about to be one of the most sensitive experiments searching for neutrinoless double-beta decay. Its sensitivity could be further improved by removing the background from $\alpha$ radioactivity.…
We demonstrate that Neganov-Luke amplified cryogenic light detectors with Transition Edge Sensor read-out can be applied for the background suppression in cryogenic experiments searching for the neutrinoless double beta decay of…
Bolometers have proven to be good detectors for the search of neutrinoless double beta decay. By operating at cryogenic temperatures, they feature excellent energy resolution and low background. The detection of the possible light emitted…
Bolometers have proven to be good instruments to search for rare processes because of their excellent energy resolution and their extremely low intrinsic background. In this kind of detectors, the capability of discriminating alpha…
Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10 meV. CUORE, an array of 988 TeO$_2$ bolometers being commissioned at Laboratori Nazionali del Gran Sasso in…
We present the performances of two 92% enriched $^{130}$TeO$_2$ crystals operated as thermal bolometers in view of a next generation experiment to search for neutrinoless double beta decay of $^{130}$Te. The crystals, 435 g each, show an…
In the present work, we describe the results obtained with a large ($\approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te. We demonstrate an efficient $\alpha$…
Bolometers are ideal devices in the search for neutrinoless Double Beta Decay. Enlarging the mass of individual detectors would simplify the construction of a large experiment, but would also decrease the background per unit mass induced by…
We present a new detection scheme for rejecting backgrounds in neutrino less double beta decay experiments. It relies on the detection of Cherenkov light emitted by electrons in the MeV region. The momentum threshold is tuned to reach a…
Simultaneous measurement of phonon and light signatures is an effective way to reduce the backgrounds and increase the sensitivity of CUPID, a next-generation bolometric neutrinoless double-beta decay ($0\nu\beta\beta$) experiment. Light…
$TeO_2$ crystals are used as bolometers in experiments searching for Double Beta Decay without emission of neutrinos. One of the most important issues in this extremely delicate kind of experiments is the characterization of the background.…
Identification of Cherenkov light generated by muons has been suggested as a promising way to dramatically improve the background rejection power of Imaging Atmospheric Cherenkov Telescope (IACT) arrays at high energies. However, muon…
We report the performance of two prototype TeO2 macrobolometers, operated at ~25 mK, able to identify events due to energy deposited at the detector surface. This capability is obtained by thermally coupling thin Ge active layers to the…
A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…