English
Related papers

Related papers: Charge-sensitive front-end electronics with operat…

200 papers

We report the electronic structure of CuTe with a high charge density wave (CDW) transition temperature Tc = 335 K by angle-resolved photoemission spectroscopy (ARPES). An anisotropic charge density wave gap with a maximum value of 190 meV…

Small-pitch 3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC pixel detector upgrades. Prototype 3D sensors with pixel sizes of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$…

Instrumentation and Detectors · Physics 2018-09-18 J. Lange , G. Giannini , S. Grinstein , M. Manna , G. Pellegrini , D. Quirion , S. Terzo , D. Vázquez Furelos

An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose first-stage JFET has been cooled. The operating temperature of the JFET has…

High Energy Physics - Experiment · Physics 2009-10-28 Yoshizumi Inoue , Shigetaka Moriyama , Hideyuki Hara , Makoto Minowa , Fumio Shimokoshi

In this work we investigated a method to determine time walk in an active silicon pixel sensor prototype using Edge-TCT with infrared laser charge injection. Samples were investigated before and after neutron irradiation to 5e14 neq/cm2.…

We achieve high detectivity terahertz sensing using a silicon nitride nanomechanical resonator functionalized with a metasurface absorber. High performances are achieved by striking a fine balance between the frequency stability of the…

The next generation of collider experiments require tracking detectors with extreme performance capabilities in terms of spatial resolution (tens of $\mu \text{m}$), radiation hardness ($10^{17}~1~$MeV n$_{eq}/$cm$^2$) and timing resolution…

Instrumentation and Detectors · Physics 2023-01-05 Gian Matteo Cossu , Adriano Lai

We have developed a detector of coherent terahertz (THz) radiation that can recover the full polarisation state of a THz transient. The device is three-contact photoconductive receiver, which is capable of recording two time-varying…

Other Condensed Matter · Physics 2007-05-23 M. B. Johnston , E. Castro-Camus , J. Lloyd-Hughes , M. D. Fraser , H. H. Tan , C. Jagadish

The pursuit to operate photocathodes at high accelerating gradients to increase brightness of electron beams is gaining interests within the accelerator community. Cesium telluride (Cs2Te) is a widely used photocathode material and it is…

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future…

Instrumentation and Methods for Astrophysics · Physics 2025-04-30 Kenneth W. Lin , Abby Bault , Armin Karcher , Julien Guy , Stephen E. Holland , William F. Kolbe , Peter E. Nugent

The High Resolution Energetic X-Ray Imager (HREXI) CZT detector development program at Harvard is aimed at developing tiled arrays of finely pixelated CZT detectors for use in wide-field coded aperture 3-200 keV X-ray telescopes. A pixel…

Instrumentation and Methods for Astrophysics · Physics 2020-04-09 Arkadip Basak , Branden Allen , Jaesub Hong , Daniel P. Violette , Jonathan Grindlay

Room temperature operation is mandatory for any optoelectronics technology which aims to provide low-cost compact systems for widespread applications. In recent years, an important technological effort in this direction has been made in…

The central detector in the MuSun experiment is a pad-plane time projection ionization chamber that operates without gas amplification in deuterium at 31 K; it is used to measure the rate of the muon capture process $\mu^- + d \rightarrow n…

In recent years, SiPM photoelectric devices have drawn much attention in the domain of time-of-flight-based positron emission tomography (TOF-PET). Using them to construct PET detectors with excellent coincidence time resolution (CTR) is…

Instrumentation and Detectors · Physics 2018-06-08 Liwei Wang , Yonggang Wang , Qiang Cao , Yong Xiao , Chong Liu

The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small…

Active edge p-on-p silicon pixel detectors with thickness of 100 $\mu$m were fabricated on 150 mm Float zone silicon wafers at VTT. By combining measured results and TCAD simulations, a detailed study of electric field distributions and…

Instrumentation and Detectors · Physics 2016-02-17 T. Peltola , X. Wu , J. Kalliopuska , C. Granja , J. Jakubek , M. Jakubek , J. Härkönen , A. Gädda

The physics aims at the proposed future CLIC high-energy linear $e^+ e^-$ collider pose challenging demands on the performance of the detector system. In particular the vertex and tracking detectors have to combine precision measurements…

Instrumentation and Detectors · Physics 2019-09-04 Mathieu Benoit

Developing low-power, high-sensitivity photodetectors for the terahertz (THz) band that operate at room temperature is an important challenge in optoelectronics. In this study, we introduce a photo-thermal-electric (PTE) effect detector…

In this paper the PreAmplifier ShAper (PASA) for the Time Projection Chamber (TPC) of the ALICE experiment at LHC is presented. The ALICE TPC PASA is an ASIC that integrates 16 identical channels, each consisting of Charge Sensitive…

Instrumentation and Detectors · Physics 2012-03-19 H. K. Soltveit , J. Stachel , P. Braun-Munzinger , L. Musa , H. A. Gustafsson , U. Bonnes , H. Oeschler , L. Osterman , S. Lang

The upgraded Inner Tracking System (ITS2) of the ALICE experiment at the CERN Large Hadron Collider is based on Monolithic Active Pixel Sensors (MAPS). With a sensitive area of about 10 $m^2$ and 12.5 billion pixels, ITS2 represents the…

Instrumentation and Detectors · Physics 2025-05-29 Nicolo' Valle

A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device…

‹ Prev 1 8 9 10 Next ›