A novel approach for measuring the electrical resistivity of non-magnetic materials using magnetic force microscopy (MFM) is discussed. In this method, MFM detects magnetic fields generated by eddy currents induced by the oscillation of a…
Ferromagnetic resonance in conducting magnetic bilayers was studied using microstrip transducers. It was found that excitation or suppression of standing spin waves could be achieved through enhanced inhomogeneity of eddy currents in the…
We develop the theoretical framework for calculating magnetic noise from conducting two-dimensional (2D) materials. We describe how local measurements of this noise can directly probe the wave-vector dependent transport properties of the…
Magnetic field source localization and imaging happen at different scales. The sensing baseline ranges from meter scale such as magnetic anomaly detection, centimeter scale such as brain field imaging to nanometer scale such as the imaging…
Recently we have developed a spin Hall magnetoresistance (SMR) sensor which operates under AC bias and sense currents. Here we demonstrate both theoretically and experimentally that the SMR sensor is uniquely suited for eddy current testing…
We demonstrate electromagnetic induction imaging with an unshielded, portable radio-frequency atomic magnetometer scanning over the target object. This configuration satisfies standard requirements in typical applications, from security…
In this work, a burst eddy current testing technique based on the employment of a diamond nitrogen vacancy (NV) center magnetometer with the Hahn echo (HE) sequence is demonstrated. With the confocal experiment apparatus, the HE-based NV…
Rydberg-atom electric field sensing has shown great potential from near-DC to THz with state-of-the-art measurement metrics realized in sensitivity, phase extraction, multi-band receptivity, etc. While Rydberg-atom sensors have shown…
Eddy current flow meters (ECFM) are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid,…
We experimentally demonstrate a simple and robust protocol for the detection of weak radio-frequency magnetic fields using a single electron spin in diamond. Our method relies on spin locking, where the Rabi frequency of the spin is…
This letter proposes a new method based on ultrafast high energy electron radiography to diagnose transient electromagnetic field. For the traditional methods, large scattering from matter will increase the uncertainty of measurement, but…
We describe a method to dispersively detect all three vector components of an external magnetic field using alkali atoms based on the Voigt effect. Our method relies on measuring the linear birefringence of the radio frequency dressed…
An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in…
Rydberg atom-based electrometry enables traceable electric field measurements with high sensitivity over a large frequency range, from gigahertz to terahertz. Such measurements are particularly useful for the calibration of radio frequency…
We present a novel approach to detect millicharged dark matter (mDM) by using a high-sensitivity magnetometer coupled with the resonant and broadband readout circuits. In the external magnetic field, the interaction between mDM and the…
Extensive research papers of three-dimensional computational techniques are widely used for the investigation of human brain pathophysiology. Eddy current analyzing could provide an indication of conductivity change within a biological…
We demonstrate a fast three-axis optical magnetometer using cold, optically-trapped $^{87}$Rb gas as a sensor. By near-resonant Faraday rotation we record the free-induction decay following optical pumping along two orthogonal axes to…
Quantum sensors often consist of packaging, such as dielectric-based vapor cells and metallic electrodes, that reduces and spatially alters the locally observed electromagnetic fields. These effects have been well studied in the optical…
We demonstrate a paraffin-coated planar reflective multipass vapor cell for compact optical atomic magnetometry. The cell has an internal volume of $12 \times 12 \times 8~\mathrm{mm}^3$ and supports 20 optical passes with a total…
We report on widefield microwave vector field imaging with sub um resolution using a microfabricated alkali vapor cell. The setup can additionally image dc magnetic fields, and can be configured to image microwave electric fields. Our…