English
Related papers

Related papers: SiPM Gain Stabilization Studies for Adaptive Power…

200 papers

Recently, vacancy-related spin defects in silicon carbide (SiC) have been demonstrated to be potentially suitable for versatile quantum interface building and scalable quantum network construction. Significant efforts have been undertaken…

Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…

Instrumentation and Detectors · Physics 2020-01-29 V. Mikhaylov , F. Guber , A. Ivashkin , A. Kugler , V. Kushpil , S. Morozov , O. Svoboda , P. Tlusty

Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes…

Instrumentation and Detectors · Physics 2010-09-01 Gamal Ahmed , Paul Buehler , Michael Cargnelli , Roland Hohler , Johann Marton , Herbert Orth , Ken Suzuki

In a power grid with growing penetrations of renewable energy sources, inverters play a larger role in the dynamic interactions among network components. However, much is yet to be studied regarding inverter-dominated grid stability. This…

Systems and Control · Electrical Eng. & Systems 2023-11-22 Ruth Kravis , Gabriel Colon-Reyes , Duncan Callaway

In highly anisotropic layered cuprates such as Bi$_2$Sr$_2$CaCu$_2$O$_{8+x}$ tunneling measurements on a stack of intrinsic junctions in a high-bias range are often susceptible to self-heating. In this study we monitored the temperature…

Superconductivity · Physics 2009-11-11 Myung-Ho Bae , Jae-Hyun Choi , Hu-Jong Lee

The characteristics of triple GEM detectors have been studied systematically by using cosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting. Efficiency of GEM detector has been…

Instrumentation and Detectors · Physics 2015-06-17 S. Biswas , D. J. Schmidt , A. Abuhoza , U. Frankenfeld , C. Garabatos , J. Hehner , V. Kleipa , T. Morhardt , C. J. Schmidt , H. R. Schmidt , J. Wiechula

Point defects introduce localized electronic states that critically affect carrier trapping, recombination, and transport in functional materials. The associated charge transition levels (CTLs) can depend on temperature, requiring accurate…

Materials Science · Physics 2025-12-18 Tobias Hainer , Ethan Berger , Esmée Berger , Olof Hildeberg , Paul Erhart , Julia Wiktor

The footprint of inflation in the polarization pattern of the CMB is expected at more than an order of magnitude below the limits of current polarization measurements. Large receiver arrays are mandatory for achieving the required…

Astrophysics · Physics 2019-08-13 Dorothea Samtleben

This paper presents an extremum seeking control (ESC) method for cooling tower fans to minimize overall power consumption of a chilled water plant system. Simulation studies across different climate locations demonstrate energy savings of…

Systems and Control · Electrical Eng. & Systems 2026-05-18 Min Gyung Yu , Alex Vlachokostas , Karthik Devaprasad , Matt Cornachione , Stephanie Johnson , Tim A. Yoder , Timothy I. Salsbury

Stabilizing the gain of a radio astronomy receiver is of great importance for sensitive radio intensity mapping. In this paper we discuss a stabilization method using a continuous-wave reference signal injected into the signal chain and…

Instrumentation and Methods for Astrophysics · Physics 2019-08-21 Alexander W. Pollak , Christian M. Holler , Michael E. Jones , Angela C. Taylor

In this paper, we report the measurement of the neutron radiation hardness of custom Silicon Photomultipliers arrays (SiPMs) manufactured by three companies: Hamamatsu (Japan), AdvanSiD (Italy) and SensL (Ireland). These custom SiPMs…

Instrumentation and Detectors · Physics 2018-04-18 M. Cordelli , E. Diociaiuti , R. Donghia , A. Ferrari , S. Miscetti , S. Muller , I. Sarra

Self-heating in surrounding gate transistors can degrade its on-current performance and reduce lifetime. If a transistor heats/cools with time-constants less than the inverse of the operating frequency, a predictable, frequency-independent…

Instrumentation and Detectors · Physics 2016-09-02 SangHoon Shin , Muhammad Masuduzzaman , Muhammad Ashraful Alam

A setup is designed for measuring the Seebeck coefficient (S) of materials in form of thin film, bar and wire. The main feature of this setup is control in heating and cooling cycles. In this setup heat pulse is used to generate the…

Instrumentation and Detectors · Physics 2019-11-05 Abdul Ahad , D. K. Shukla

To achieve an uncertainty of 0.25 mK in single-pressure refractive-index gas thermometry (SPRIGT), the relative pressure variation of He-4 gas in the range 30 kPa to 90 kPa, should not exceed 4 ppm (k=1). To this end, a novel pressure…

Instrumentation and Detectors · Physics 2020-02-11 Bo Gao , Hui Chen , Dongxu Han , Pascal Gambette , Haiyang Zhang , Changzhao Pan , Yingwen Liu , Bo Yu , Ercang Luo , Mark Plimmer , Laurent Pitre

We developed a cryogenic photon readout system to monitor arrays of DUNE SiPMs operating at various over-voltages in liquid nitrogen (LN2) for over three months. Photoelectron signals were read out simultaneously via weak capacitive…

Instrumentation and Detectors · Physics 2026-05-26 Thomas Tsang , Flavio Cavanna , Hucheng Chen , Shanshan Gao , Lingyun Ke , Koloina Rambeloson

In this paper we report on the characterization of SiPM tiles developed for the R & D on the DUNE Photon Detection System. The tiles were produced by Fondazione Bruno Kessler (FBK) employing NUV-HD-SF SiPMs. Special emphasis is given on…

Direct observation of temperature dependence of individual bands of semiconductors for a wide temperature region is not straightforward, in particular. However, this fundamental property is a prerequisite in understanding the…

Materials Science · Physics 2020-01-08 E. Cannuccia , A. Gali

In recent years, SiPM photoelectric devices have drawn much attention in the domain of time-of-flight-based positron emission tomography (TOF-PET). Using them to construct PET detectors with excellent coincidence time resolution (CTR) is…

Instrumentation and Detectors · Physics 2018-06-08 Liwei Wang , Yonggang Wang , Qiang Cao , Yong Xiao , Chong Liu

A simple, self-contained, thermo-electrically cooled SiPM system is presented which cools a SiPM array to -20 C. The array views a NaI scintillator through a 75 mm diameter glass window. Waste heat is removed with a large heat sink and AC…

Instrumentation and Detectors · Physics 2019-08-26 A. Ponento , C. J. Martoff , D. Jones , E. Kaczanowicz

A coherent Ising machine (CIM) is known to deliver the low-energy states of the Ising model. Here, we investigate how well the CIM simulates the thermodynamic properties of a two-dimensional square-lattice Ising model. Assuming that the…