Related papers: MCP-based Photodetectors for Cryogenic Application…
Current generation of detectors using noble gases in liquid phase for direct dark matter search and neutrino physics need large area photosensors. Silicon based photo-detectors are innovative light collecting devices and represent a…
We report on the realization of a novel SiPM-based, cryogenic photosensor with an active area of 24 cm$^2$ that operates as a single-channel analog detector. The device is capable of single photon counting with a signal to noise ratio…
We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…
Silicon photomultipliers (SiPM) have gained significant traction as an alternative technology to the well-established photomultiplier tube (PMT), with numerous high-sensitivity experiments adopting them either complementarily or as a…
The Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrinos (CAPTAIN) is being built at Los Alamos National Laboratory. A hexagonal time projection chamber (TPC) with a 1 m drift length will be constructed inside a…
Microchannel plates (MCPs) were the driving detector technology for ultraviolet (UV) astronomy over many years, and still today MCP-based detectors are the baseline for several planned UV instruments. The development of advanced MCP…
Large (up to $\sim 100$ kt) liquid argon time-projection chamber detectors are presently being considered for proton decay searches and neutrino astrophysics, as well as for far detectors for the next generation of long-baseline neutrino…
I discuss the status of MCP-based photo-detector amplification sections and Cherenkov light sources for precise timing measurements of charged particles and gamma rays. Sub-psec resolution is predicted for the large pulses such as those…
Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time…
A new cryogenic packaging methodology that is widely applicable to packaging any integrated photonics circuit for operation at both room temperature and cryogenic temperature is reported. The method requires only equipment and techniques…
Interfacing single-photon detectors with active photonic components is a cornerstone photonic quantum technology. We describe how the output signal of commercial superconducting nanowire single-photon detectors can be used in situ to drive…
WIMPs (Weakly Interacting Massive Particles) are considered the main candidates for Cold Dark Matter. The ArDM experiment aims at measuring signals directly induced by WIMPs in liquid argon. A 1-ton prototype is currently developed with the…
The ARAPUCA is a novel concept for liquid argon scintillation light detection which has been proposed for the photon detection system of the Deep Underground Neutrino Experiment. The test in liquid argon of one of the first ARAPUCA…
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for…
Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…
Microchannel plates (MCPs) were recently proposed as novel type of cathodes for electron guns, suitable for applications in design of electron lenses. We report results of the first systematic study of microchannel plate based…
We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on…
The PICOSEC Micromegas detector is a precise-timing gaseous detector that combines a Cherenkov radiator, a semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum…
An event-counting thermal neutron imaging detector based on 3 mol % natGd2O3 doped micro channel plate (MCP) has been developed and tested. Thermal neutron imaging experiment was carried out with a low flux neutron beam. Detection…
The single photoelectron performance characteristics of a Large Area Picosecond PhotoDetector (LAPPD) were studied using a picosecond optical laser source. We verify that the LAPPD is capable of achieving transit time spreads of less than…