Related papers: A Rn-220 source for the calibration of low-backgro…
We report preliminary results from an arcsecond-resolution X-ray survey of nearby galaxies using ACIS on board Chandra. The total sample consists of 41 low-luminosity AGNs, including Seyferts, LINERs, and LINER/H II transition objects. In…
We describe the design and construction of the low rate neutron calibration sources used in the Daya Bay Reactor Anti-neutrino Experiment. Such sources are free of correlated gamma-neutron emission, which is essential in minimizing induced…
Mono-energetic gamma-beams ($\Delta\sim 10$ eV) based on thermal neutron capture, in a nuclear reactor, using the V(n, $\gamma$) and Fe(n,$\gamma$) reactions, were utilized for generating fast neutron sources from lead and thallium…
We propose to search for coherent neutrino-nucleus scattering (CNNS)by means of a triple-sectioned low background proportional counter. As a working medium we plan to use argon and xenon at about 1 MPa. We have shown using bench-scale…
We present the first results of the Chandra Cool Targets (CCT) survey of the Second Bologna Catalog (B2CAT) of powerful radio sources, aimed at investigating the extended X-ray emission surrounding these sources. For the first 33 sources…
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that…
Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr…
We present a sample of eight extended X-ray sources detected in the wide-field (~2.3 deg^2), bright (2-10 ksec) XMM-Newton/2dF survey, reaching a flux limit of ~2 X 10^{-14} erg/s/cm^2. Of these, seven are identified as secure X-ray…
We detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8$\times10^6$~dpm) \nuc{99}{Tc} $\beta$ source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device…
We observed at 22 GHz with the VLBI array VERA a sample of 1536 sources with correlated flux densities brighter than 200 mJy at 8 GHz. One half of target sources has been detected. The detection limit was around 200 mJy. We derived the…
A plasma focus device capable of operating at 0.2 pulses per second during several minutes is used as a source of hard x-rays and fast neutrons. An experimental demonstration of the use of the neutrons emissions for radiation probing of…
We explore the discovery potential for long-lived particles at the 250-GeV ILC. The goal is to investigate possible gains of a dedicated far detector over the main detector ILD. For concreteness, we perform our study for sub-GeV axion-like…
A high-pressure xenon gas time projection chamber, with a unique cellular readout structure based on electroluminescence, has been developed for a large-scale neutrinoless double-beta decay search. In order to evaluate the detector…
Plasma diagnostics have a shortage of fast and sensitive calorimetric sensors that can track substrate temperature during plasma-assisted microfabrication. In this work, energy fluxes from argon and oxygen radiofrequency (RF) glow…
First test of the 4pi detector for study of exponential law of radioactive decay and possibility of observation of Zeno effect [1-3], measuring the mean life of 216Po is presented. This detector consists of two surface-barrier n-Si(Au)…
We demonstrate the capability of ab-initio time-dependent R-matrix theory to obtain accurate harmonic generation spectra of noble-gas atoms at Near-IR wavelengths between 1200 and 1800 nm and peak intensities up to 1.8 X 10(14) W/cm(2) . To…
We present a catalog of 321 compact radio sources in the declination range 0deg > delta > -30deg. The positions of these sources have been measured with a two-dimensional rms accuracy of 35 milliarcseconds using the NRAO Very Large Array.…
We have searched for extended X-ray sources in the ROSAT PSPC archive using the Voronoi Tesslation and Percolation algorithm (VTP). This algorithm detects all significant sources regardless of shape or size, and is particularly suited to…
Long-lived alpha and beta emitters in the $^{222}$Rn decay chain on detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double-beta decay. Removal of tens of microns of…
We construct a high sensitivity radon pilot detector using liquid scintillator dissolved radon for the CDEX rare-event searches program. The CDEX-10 project employs a germanium detector array immersed in a massive liquid nitrogen tank.…