English
Related papers

Related papers: Calibration scheme for large Kinetic Inductance De…

200 papers

We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting…

We show measurements of thermal kinetic inductance detectors (TKID) intended for millimeter wave cosmology in the 200-300 GHz atmospheric window. The TKID is a type of bolometer which uses the kinetic inductance of a superconducting…

Instrumentation and Methods for Astrophysics · Physics 2018-08-01 Bryan A. Steinbach , James J. Bock , Hien T. Nguyen , Roger C. O'Brient , Anthony D. Turner

Within this proceeding, we introduce the U-Board platform, a versatile platform for signal generation, acquisition and processing, based on a heterogenous processing architecture. Based on this platform we present a readout for Microwave…

Instrumentation and Methods for Astrophysics · Physics 2023-10-10 Gerrit Grutzeck , Ingo Krämer , Miroslaw Ciechanowicz , Nicolas Reyes , Carsten König , Andrey Baryshev , Stephen Yates , Bernd Klein

Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct…

A number of modern millimeter, sub-millimeter, and far-infrared detectors are read out using superconducting microwave (1-10GHz) resonators. The main detector technologies are Transition Edge Sensors, read out using Microwave SQUID…

Instrumentation and Detectors · Physics 2022-08-08 Max Silva-Feaver , Zeeshan Ahmed , Kam Arnold , Josef C. Frisch , John Groh , Shawn W. Henderson , Jesus Vasquez , Cyndia Yu

We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments…

A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector. It comprises a resonator circuit constructed with a superconducting film on a dielectric substrate. To expand its field of application, it is…

Instrumentation and Detectors · Physics 2022-03-16 Yoshinori Sueno , Shunsuke Honda , Hiroki Kutsuma , Satoru Mima , Chiko Otani , Shugo Oguri , Junya Suzuki , Osamu Tajima

Kinetic inductance bolometer (KIB) technology is a candidate for passive sub-millimeter wave and terahertz imaging systems. Its benefits include scalability into large 2D arrays and operation with intermediate cryogenics in the temperature…

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance…

Instrumentation and Methods for Astrophysics · Physics 2025-03-25 E. S. Martsen , P. S. Barry , B. A. Benson , K. R. Dibert , K. N. Fichman , T. Natoli , M. Rouble , C. Yu

Kinetic inductance detectors (KIDs) have been proven as reliable systems for astrophysical observations, especially in the millimetre range. Their compact size enables to optimally fill the focal plane, thus boosting sensitivity. The KISS…

We present the performance of a superconducting nanowire that can be operated in two detection modes: i) as a kinetic inductance detector (KID) or ii) as a single-photon detector (SPD). Two superconducting nanowires developed for use as…

Instrumentation and Detectors · Physics 2018-11-14 Edward Schroeder , Philip Mauskopf , Hamdi Mani , Sean Bryan , Karl K. Berggren , Di Zhu

Superconducting resonators with high quality factors are extremely sensitive detectors of the complex impedance of materials and devices coupled to them. This capability has been used to measure losses in multiple different materials and,…

Quantum Physics · Physics 2025-07-01 Jared Gibson , Zhanzhi Jiang , Angela Kou

Focal plane arrays consisting of low-noise, polarisation-sensitive detectors have made possible the pioneering advances in the study of the cosmic microwave background (CMB). To make further progress, the next generation of CMB experiments…

Instrumentation and Methods for Astrophysics · Physics 2018-06-13 P. S. Barry , S. Doyle , A. L. Hornsby , A. Kofman , E. Mayer , Q. Y. Tang , J. Vieira , E. Shirokoff

We have fabricated planar amorphous Indium Oxide superconducting resonators ($T_c\sim2.8$ K) that are sensitive to frequency-selective radiation in the range of 7 to 10 GHz. Those values lay far below twice the superconducting gap that…

Selected for the next generation of adaptive optics (AO) systems, the pyramid wavefront sensor (PWFS) is recognised for its closed AO loop performance. As new technologies are emerging, it is necessary to explore new methods to improve it.…

Instrumentation and Methods for Astrophysics · Physics 2022-09-26 Aurelie Magniez , Lisa Bardou , Tim Morris , Kieran O'Brien

This paper describes the energy resolution of Microwave Kinetic Inductance Detectors (MKIDs), and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons,…

Instrumentation and Detectors · Physics 2024-02-16 Mario De Lucia , Gerhard Ulbricht , Eoin Baldwin , Jack Piercy , Colm Bracken , Oisin Creaner , Tom Ray

We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC).…

Instrumentation and Methods for Astrophysics · Physics 2017-11-06 P. Szypryt , S. R. Meeker , G. Coiffard , N. Fruitwala , B. Bumble , G. Ulbricht , A. B. Walter , M. Daal , C. Bockstiegel , G. Collura , N. Zobrist , I. Lipartito , B. A. Mazin

The superconducting materials that make up an MKID have a significant effect on its performance. The $T_\textrm{c}$ and normal state resistivity $\rho_\textrm{N}$ of the film determine the penetration depth $\lambda$ and therefore how much…

Instrumentation and Methods for Astrophysics · Physics 2020-05-01 Benjamin A. Mazin

The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three…

Instrumentation and Methods for Astrophysics · Physics 2016-12-21 O. Bourrion , A. Benoit , J. L. Bouly , J. Bouvier , G. Bosson , M. Calvo , A. Catalano , J. Goupy , C. Li , J. F. Macías-Pérez , A. Monfardini , D. Tourres , N. Ponchant , C. Vescovi

The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and…

Instrumentation and Detectors · Physics 2015-09-15 L. Cardani , I. Colantoni , A. Cruciani , S. Di Domizio , M. Vignati , F. Bellini , N. Casali , M. G. Castellano , A. Coppolecchia , C. Cosmelli , C. Tomei
‹ Prev 1 3 4 5 6 7 10 Next ›