Related papers: Development and tests of a new prototype detector …
3D Silicon sensors fabricated at FBK-irst with the Double-side Double Type Column (DDTC) approach and columnar electrodes only partially etched through p-type substrates were tested in laboratory and in a 1.35 Tesla magnetic field with a…
Event-based image sensors provide microsecond temporal resolution but lack spectral discrimination, whereas diffractive spectral imagers encode wavelength information at conventional frame rates. We introduce a fluorescence microscopy…
When an X-ray area detector based on a single crystalline material, for instance, a state of the art hybrid pixel detector, is illuminated from a point source by monochromatic radiation, a pattern of lines appears which overlays the…
We are developing the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last…
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch,…
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi…
The HERMES-TP/SP mission, based on a nanosatellite constellation, has very stringent constraints of sensitivity and compactness, and requires an innovative wide energy range instrument. The instrument technology is based on the "siswich"…
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now…
A hybrid pixel detector based on the concept of simultaneous charge integration and photon counting will be presented. The second generation of a counting and integrating X-ray prototype CMOS chip (CIX) has been operated with different…
Using a novel ultrahigh resolution ($\Delta E \sim 0.1\,$eV) setup to measure electronic features in x-ray Thomson scattering (XRTS) experiments at the European XFEL in Germany, we have studied the collective plasmon excitation in aluminium…
In the early 2030s, ESAs new X-ray observatory, Athena, is scheduled to be launched. It will carry two main instruments, one of which is the X-ray Integral Field Unit (X-IFU), an X-ray imaging spectrometer, which will consist of an array of…
We report on the experimental study made on a successive prototype of High-Voltage CMOS (HV-CMOS) ATLASPix2 sensor for the tracking detector application, developed with 180 nm feature size. These sensors are to qualify mainly the peripheral…
FASPAX (Fermi-Argonne Semiconducting Pixel Array X-ray detector) is being developed as a fast integrating area detector with wide dynamic range for time resolved applications at the upgraded Advanced Photon Source (APS.) A burst mode…
Understanding and control of thermal transport in solids at nanoscale is crucial to engineer and to enhance properties of a new generation of optoelectronic, thermoelectric, and photonic devices. In this regard, semiconductor superlattice…
STRASSE (Silicon Tracker for RAdioactive nuclei Studies at SAMURAI Experiments) is a new detection system under construction for quasi-free scattering (QFS) measurements at 200-250 MeV/nucleon at the RIBF facility of the RIKEN Nishina…
Synchrotron light sources can provide the required spatial coherence, stability and control that is required to support the development of advanced lithography at the extreme ultraviolet and soft X-ray wavelengths that are relevant to…
Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been…
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced…
High-speed multiplex imaging of fluorescent probes is limited by a combination of spectral resolution, sensitivity, high cost and low light throughput of detectors, and filters. In this work, we present a hyperspectral detection system…
Free-electron lasers (FEL) in the extreme ultraviolet (XUV) and X-ray regime opened up the possibility for experiments at high power densities, in particular allowing for fluence-dependent absorption and scattering experiments to reveal…