English
Related papers

Related papers: Detection efficiency evaluation for a large area n…

200 papers

We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key…

Instrumentation and Detectors · Physics 2009-11-10 D. Vartsky , I. Mor , M. B. Goldberg , I. Mardor , G. Feldman , D. Bar , A. Shor , V. Dangendorf , G. Laczko , A. Breskin , R. Chechik

Microchannel plate photodetectors provide both picosecond time resolution and sub-millimeter position resolution, making them attractive photosensors for particle identification detectors of a future U.S. Electron Ion Collider. We have…

Instrumentation and Detectors · Physics 2018-12-20 Junqi Xie , Mohammad Hattawy , Mickey Chiu , Kawtar Hafidi , Edward May , Jose Repond , Robert Wagner , Lei Xia

The worldwide need to replace 3He for the neutron detection has triggered R&D on new technologies and methods. A promising one is based on commercial solid state silicon detectors coupled with thin neutron converter layers containing 6Li.…

Instrumentation and Detectors · Physics 2016-01-20 A. Pappalardo , M. Barbagallo , L. Cosentino , C. Marchetta , A. Musumarra , C. Scirè , S. Scirè , G. Vecchio , P. Finocchiaro

The production of flexible and robust thermal neutron detectors with improved properties as compared to the commercial ZnS:Ag based phosphors is here pursued, exploiting a siloxane binder, whose intrinsic properties as related to the…

Instrumentation and Detectors · Physics 2018-08-30 S. M. Carturan , M. Vesco , I. Bonesso , A. Quaranta , G. Maggioni , L. Stevanato , E. Zanazzi , T. Marchi , D. Fabris , M. Cinausero , F. Gramegna

We describe a novel photon detector which operates under an intense flux of neutrons. It is composed of lead-aerogel sandwich counter modules. Its salient features are high photon detection efficiency and blindness to neutrons. As a result…

Instrumentation and Detectors · Physics 2016-06-21 Y. Maeda , N. Kawasaki , T. Masuda , H. Morii , D. Naito , Y. Nakajima , H. Nanjo , T. Nomura , N. Sasao , S. Seki , K. Shiomi , T. Sumida , Y. Tajima

We present the results of the measurements of the detection efficiency for a 4.7 \r{A} neutron beam incident upon a detector incorporating a stack of up to five MultiWire Proportional Counters (MWPC) with Boron-coated cathodes. The cathodes…

Instrumentation and Detectors · Physics 2015-06-17 I. Stefanescu , Y. Abdullahi , J. Birch , I. Defendi , R. Hall-Wilton , C. Hoglund , L. Hultman , M. Zee , K. Zeitelhack

A large area (0.5~m $\times$ 0.5~m) thermal neutron detector was developed based on 0.32~mm-thick $^{6}$LiF:ZnS(Ag) scintillator sheets. The detector was constructed for measurements of seasonal variations in low intensity thermal neutron…

Instrumentation and Detectors · Physics 2018-07-24 Alexandre Kozlov , Dmitry Chernyak

There has been an increasing interest in the monitoring of nuclear fuel for power reactors by detecting the anti-neutrinos produced during operation. Small liquid scintillator detectors have already demonstrated sensitivity to operational…

Instrumentation and Detectors · Physics 2007-05-23 R. W. McKeown , D. E. Reyna

We report the test results for a 120 GeV proton beam incident on superconducting nanowire particle detectors of various wire sizes. NbN devices with the same sensitive area were fabricated with different wire widths and tested at a…

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…

A double-helix electrode configuration is combined with a $^{10}$B powder coating technique to build large-area (9 in $\times$ 36 in) neutron detectors. The neutron detection efficiency for each of the four prototypes is comparable to a…

Instrumentation and Detectors · Physics 2023-08-22 Zhehui Wang , C. L. Morris , J. D. Bacon , M. I. Brockwell , J. C. Ramsey

Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified…

We have been developing a neutron detector with spatial resolution of submicron by loading 6Li into fine-grained nuclear emulsion. By exposure to thermal neutrons, tracks from neutron capture events were observed. From their grain density,…

Instrumentation and Detectors · Physics 2016-12-15 N. Naganawa , S. Awano , M. Hino , M. Hirose , K. Hirota , H. Kawahara , M. Kitaguchi , K. Mishima , T. Nagae , H. M. Shimizu , S. Tasaki , A. Umemoto

We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT…

Instrumentation and Detectors · Physics 2020-03-24 C. Canot , M. Alokhina , P. Abbon , J. P. Bard , D. Breton , E. Delagnes , J. Maalmi , G. Tauzin , D. Yvon , V. Sharyy

A two-dimensional position-sensitive microchannel plate detector, with a {\O}100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent…

Instrumentation and Detectors · Physics 2018-08-01 Yuezhao Zhang , Deyang Yu , Junliang Liu , Liping Yang , Wei Wang , Xiaoxiao Li , Xiaona Zhu , Xiaoxun Song , Xinfei Hui , Wei Xi , Xin Li , Huiping Liu , Xiaohong Cai

We propose to search for coherent neutrino-nucleus scattering (CNNS)by means of a triple-sectioned low background proportional counter. As a working medium we plan to use argon and xenon at about 1 MPa. We have shown using bench-scale…

Instrumentation and Detectors · Physics 2013-12-02 A. V. Kopylov , I. V. Orekhov , V. V. Petukhov , A. E. Solomatin

We experimentally investigate the performance of NbTiN superconducting nanowire single photon detectors above the base temperature of a conventional Gifford-McMahon cryocooler (2.5 K). By tailoring design and thickness (8 - 13 nm) of the…

A scalable 16-ch thermal neutron detection system has been developed in the framework of the upgrade of a neutron diffractometer. The detector is based on ZnS:${}^6$LiF scintillator with embedded WLS fibers which are read out with SiPMs. In…

Instrumentation and Detectors · Physics 2017-03-08 J. -B. Mosset , A. Stoykov , U. Greuter , A. Gromov , M. Hildebrandt , T. Panzner , N. Schlumpf

A 2D neutron detector based on 3He convertor and MWPC with an active area of 200 mm \times 200 mm has been successfully designed and fabricated. The detector has been tested with Am/Be neutron source and with collimated neutron beam with…

Instrumentation and Detectors · Physics 2013-05-23 Tian LiChao , Chen YuanBo , Tang Bin , Zhou JianRong , Qi HuiRong , Liu RongGuang , Zhang Jian , Yang GuiAn , Xu Hong , Chen DongFeng , Sun ZhiJia

A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…

Instrumentation and Detectors · Physics 2014-11-24 T. J. Langford , C. D. Bass , E. J. Beise , H. Breuer , D. K. Erwin , C. R. Heimbach , J. S. Nico